Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Mechanical Loading of Cartilage Explants with Compression and Sliding Motion Modulates Gene Expression of Lubricin and Catabolic Enzymes

OR. Schätti, M. Marková, PA. Torzilli, LM. Gallo,

. 2015 ; 6 (3) : 185-93.

Language English Country United States

Document type Journal Article

OBJECTIVE: Translation of the contact zone in articulating joints is an important component of joint kinematics, yet rarely investigated in a biological context. This study was designed to investigate how sliding contact areas affect cartilage mechanobiology. We hypothesized that higher sliding speeds would lead to increased extracellular matrix mechanical stress and the expression of catabolic genes. DESIGN: A cylindrical Teflon indenter was used to apply 50 or 100 N normal forces at 10, 40, or 70 mm/s sliding speed. Mechanical parameters were correlated with gene expressions using a multiple linear regression model. RESULTS: In both loading groups there was no significant effect of sliding speed on any of the mechanical parameters (strain, stress, modulus, tangential force). However, an increase in vertical force (from 50 to 100 N) led to a significant increase in extracellular matrix strain and stress. For 100 N, significant correlations between gene expression and mechanical parameters were found for TIMP-3 (r(2) = 0.89), ADAMTS-5 (r(2) = 0.73), and lubricin (r(2) = 0.73). CONCLUSIONS: The sliding speeds applied do not have an effect on the mechanical response of the cartilage, this could be explained by a partial attainment of the "elastic limit" at and above a sliding speed of 10 mm/s. Nevertheless, we still found a relationship between sliding speed and gene expression when the tissue was loaded with 100 N normal force. Thus despite the absence of speed-dependent mechanical changes (strain, stress, modulus, tangential force), the sliding speed had an influence on gene expression.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15031286
003      
CZ-PrNML
005      
20210209105158.0
007      
ta
008      
151005s2015 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1177/1947603515581680 $2 doi
035    __
$a (PubMed)26175864
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Schätti, Oliver R $u Laboratory of Physiology and Biomechanics of the Masticatory System, Center for Oral Medicine, Dental and Maxillo-Facial Surgery, University of Zurich, Plattenstrasse, Zurich, Switzerland ; Institute for Biomechanics, Swiss Federal Institute of Technology, ETH Zentrum, Zurich, Switzerland ; Laboratory for Soft Tissue Research, Hospital for Special Surgery, New York, NY, USA.
245    10
$a Mechanical Loading of Cartilage Explants with Compression and Sliding Motion Modulates Gene Expression of Lubricin and Catabolic Enzymes / $c OR. Schätti, M. Marková, PA. Torzilli, LM. Gallo,
520    9_
$a OBJECTIVE: Translation of the contact zone in articulating joints is an important component of joint kinematics, yet rarely investigated in a biological context. This study was designed to investigate how sliding contact areas affect cartilage mechanobiology. We hypothesized that higher sliding speeds would lead to increased extracellular matrix mechanical stress and the expression of catabolic genes. DESIGN: A cylindrical Teflon indenter was used to apply 50 or 100 N normal forces at 10, 40, or 70 mm/s sliding speed. Mechanical parameters were correlated with gene expressions using a multiple linear regression model. RESULTS: In both loading groups there was no significant effect of sliding speed on any of the mechanical parameters (strain, stress, modulus, tangential force). However, an increase in vertical force (from 50 to 100 N) led to a significant increase in extracellular matrix strain and stress. For 100 N, significant correlations between gene expression and mechanical parameters were found for TIMP-3 (r(2) = 0.89), ADAMTS-5 (r(2) = 0.73), and lubricin (r(2) = 0.73). CONCLUSIONS: The sliding speeds applied do not have an effect on the mechanical response of the cartilage, this could be explained by a partial attainment of the "elastic limit" at and above a sliding speed of 10 mm/s. Nevertheless, we still found a relationship between sliding speed and gene expression when the tissue was loaded with 100 N normal force. Thus despite the absence of speed-dependent mechanical changes (strain, stress, modulus, tangential force), the sliding speed had an influence on gene expression.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Marková, Michala $u Laboratory of Physiology and Biomechanics of the Masticatory System, Center for Oral Medicine, Dental and Maxillo-Facial Surgery, University of Zurich, Plattenstrasse, Zurich, Switzerland ; Laboratory of Biomechanics, Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech Republic.
700    1_
$a Torzilli, Peter A $u Laboratory for Soft Tissue Research, Hospital for Special Surgery, New York, NY, USA.
700    1_
$a Gallo, Luigi M $u Laboratory of Physiology and Biomechanics of the Masticatory System, Center for Oral Medicine, Dental and Maxillo-Facial Surgery, University of Zurich, Plattenstrasse, Zurich, Switzerland.
773    0_
$w MED00188028 $t Cartilage $x 1947-6035 $g Roč. 6, č. 3 (2015), s. 185-93
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26175864 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20210209105154 $b ABA008
999    __
$a ind $b bmc $g 1092162 $s 914412
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 6 $c 3 $d 185-93 $i 1947-6035 $m Cartilage $n Cartilage $x MED00188028
LZP    __
$a Pubmed-20151005

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...