Use of Xe-Derma(®), a novel biological cover, in a female patient with toxic epidermal necrolysis

B. Lipový, H. Rihová, Y. Kaloudová, R. Mager, I. Suchánek,

. 2014 ; 27 (3) : 136-40.

Jazyk angličtina Země Itálie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15031289

Toxic epidermal necrolysis is a rare condition involving the skin at the dermoepidermal junction, with possible inclusion of mucous membranes. The condition is associated with systemic toxicity and high mortality rates. Successful treatment requires optimization of local as well as systemic therapy. We report the case of a young woman who developed toxic epidermal necrolysis, possibly resulting from lamotrigine therapy. Local therapy included a combination of a biological cover and alginate together with a synthetic cover (Aquacel Ag®).

000      
00000naa a2200000 a 4500
001      
bmc15031289
003      
CZ-PrNML
005      
20151007115304.0
007      
ta
008      
151005s2014 it f 000 0|eng||
009      
AR
035    __
$a (PubMed)26170792
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Lipový, B $u Burn and Reconstructive Surgery Center, University Hospital, Brno, Czech Republic ; Medical School, Masaryk University, Brno, Czech Republic.
245    10
$a Use of Xe-Derma(®), a novel biological cover, in a female patient with toxic epidermal necrolysis / $c B. Lipový, H. Rihová, Y. Kaloudová, R. Mager, I. Suchánek,
520    9_
$a Toxic epidermal necrolysis is a rare condition involving the skin at the dermoepidermal junction, with possible inclusion of mucous membranes. The condition is associated with systemic toxicity and high mortality rates. Successful treatment requires optimization of local as well as systemic therapy. We report the case of a young woman who developed toxic epidermal necrolysis, possibly resulting from lamotrigine therapy. Local therapy included a combination of a biological cover and alginate together with a synthetic cover (Aquacel Ag®).
655    _2
$a časopisecké články $7 D016428
700    1_
$a Rihová, H $u Burn and Reconstructive Surgery Center, University Hospital, Brno, Czech Republic.
700    1_
$a Kaloudová, Y $u Burn and Reconstructive Surgery Center, University Hospital, Brno, Czech Republic.
700    1_
$a Mager, R $u Burn and Reconstructive Surgery Center, University Hospital, Brno, Czech Republic.
700    1_
$a Suchánek, I $u Burn and Reconstructive Surgery Center, University Hospital, Brno, Czech Republic.
773    0_
$w MED00006824 $t Annals of burns and fire disasters $x 1592-9558 $g Roč. 27, č. 3 (2014), s. 136-40
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26170792 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20151007115450 $b ABA008
999    __
$a ind $b bmc $g 1092165 $s 914415
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 27 $c 3 $d 136-40 $i 1592-9558 $m Annals of burns and fire disasters $n Ann Burns Fire Disasters $x MED00006824
LZP    __
$a Pubmed-20151005

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...