Sensitive determination of glutathione in biological samples by capillary electrophoresis with green (515 nm) laser-induced fluorescence detection
J. Hodáková, J. Preisler, F. Foret, P. Kubáň,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- dechové testy MeSH
- elektroforéza kapilární metody MeSH
- fluorescence MeSH
- glutathion analýza MeSH
- lasery * MeSH
- lidé MeSH
- sliny chemie MeSH
- tělesné tekutiny chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A new sensitive capillary electrophoretic method with laser-induced fluorescence (LIF) was developed for quantitation of glutathione (GSH) in biological samples. Eosin-5-maleimide was used to label the GSH molecule and the formed conjugate was separated in a 15 mM 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid electrolyte at pH 7.0 in less than 3 min. The conjugate was detected with an in-house built LIF system, utilizing an inexpensive 515 nm diode laser module. Studies were performed to optimize the derivatization (the ratio of reagent to analyte, the reaction time, pH, etc.) and separation conditions. Sensitive detection of GSH at concentrations as low as 0.18 nM was obtained. The method was applied in the analysis of biological fluids (exhaled breath condensate, saliva) and was found to be suitable for determination of GSH in these samples at trace levels below 1 nM. To the best of our knowledge, this is the first report on determination of GSH in exhaled breath condensate by capillary electrophoresis (CE).
Bioanalytical Instrumentation CEITEC Masaryk University Veveří 97 602 00 Brno Czech Republic
Department of Chemistry Masaryk University Kotlářská 2 611 37 Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15031435
- 003
- CZ-PrNML
- 005
- 20151013124319.0
- 007
- ta
- 008
- 151005s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2015.02.062 $2 doi
- 035 __
- $a (PubMed)25757819
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Hodáková, Júlia $u Department of Chemistry, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic.
- 245 10
- $a Sensitive determination of glutathione in biological samples by capillary electrophoresis with green (515 nm) laser-induced fluorescence detection / $c J. Hodáková, J. Preisler, F. Foret, P. Kubáň,
- 520 9_
- $a A new sensitive capillary electrophoretic method with laser-induced fluorescence (LIF) was developed for quantitation of glutathione (GSH) in biological samples. Eosin-5-maleimide was used to label the GSH molecule and the formed conjugate was separated in a 15 mM 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid electrolyte at pH 7.0 in less than 3 min. The conjugate was detected with an in-house built LIF system, utilizing an inexpensive 515 nm diode laser module. Studies were performed to optimize the derivatization (the ratio of reagent to analyte, the reaction time, pH, etc.) and separation conditions. Sensitive detection of GSH at concentrations as low as 0.18 nM was obtained. The method was applied in the analysis of biological fluids (exhaled breath condensate, saliva) and was found to be suitable for determination of GSH in these samples at trace levels below 1 nM. To the best of our knowledge, this is the first report on determination of GSH in exhaled breath condensate by capillary electrophoresis (CE).
- 650 _2
- $a tělesné tekutiny $x chemie $7 D001826
- 650 _2
- $a dechové testy $7 D001944
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a glutathion $x analýza $7 D005978
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a lasery $7 D007834
- 650 _2
- $a sliny $x chemie $7 D012463
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Preisler, Jan $u Department of Chemistry, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic.
- 700 1_
- $a Foret, František $u Bioanalytical Instrumentation, CEITEC Masaryk University, Veveří 97, 602 00 Brno, Czech Republic.
- 700 1_
- $a Kubáň, Petr $u Department of Chemistry, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic; Bioanalytical Instrumentation, CEITEC Masaryk University, Veveří 97, 602 00 Brno, Czech Republic. Electronic address: petr.kuban@ceitec.muni.cz.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A. Including electrophoresis and other separation methods $x 1873-3778 $g Roč. 1391, č. - (2015), s. 102-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25757819 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20151005 $b ABA008
- 991 __
- $a 20151013124509 $b ABA008
- 999 __
- $a ok $b bmc $g 1092311 $s 914561
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 1391 $c - $d 102-8 $e 20150226 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962 $o Including electrophoresis and other separation methods
- LZP __
- $a Pubmed-20151005