New type of protective hybrid and nanocomposite hybrid coatings containing silver and copper with an excellent antibacterial effect especially against MRSA

I. Šlamborová, V. Zajícová, J. Karpíšková, P. Exnar, I. Stibor,

. 2013 ; 33 (1) : 265-73. (Materials for biological applications) [pub] 20120906

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15032117

Epidemics spread many types of pathogenic bacterial strains, especially strains of MRSA (Methicillin-resistant Staphylococcus aureus), which are being increasingly reported in many geographical areas [1]. This is becoming to be a serious global problem, particularly in hospitals. Not only are antibiotics proving to be increasingly ineffective but also the bacteria responsible for more than 70% of hospital-acquired bacterial infections are resistant to at least one of the drugs commonly used to treat them. In this study, hybrid coating A1 and nanocomposite hybrid coating A2 based on TMSPM (3-(trimethoxysilyl)propyl methacrylate, MMA (methyl methacrylate), TEOS (tetraethyl orthosilicate) and IPTI (titanium isopropoxide) containing silver and copper ions with or without nanoparticles of titanium dioxide were prepared by the sol-gel method. They were deposited on glass, poly(methyl methacrylate) and cotton using dip-coating or spin-coating, and then cured at 150 °C for 3 h or, in the case of poly(methyl methacrylate), at 100 °C for 4.5 h. The morphology and microstructure of these hybrid coatings were examined by SEM. The abrasion resistance was tested using a washability tester and found to depend heavily on the curing temperature. Seven types of bacterial strains were used to determine the profile of antibacterial activity, namely Escherichia coli, Staphylococcus aureus, Methicillin-resistant Staphylococcus aureus - MRSA (CCM 4223), MRSA-2 (CCM 7112), Acinetobacter baumanii, Pseudomonas aeruginosa, and Proteus vulgaris (according to ALE-G18, CSNI). All the samples were tested by irradiating with either a UV-A or a daylight fluorescent lamp. All types of hybrid coating A1 and nanocomposite hybrid coating A2 were found to possess an excellent antibacterial effect, including against the pathogenic bacterial strains of MRSA, which present a dangerous threat on a global scale.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15032117
003      
CZ-PrNML
005      
20210427133316.0
007      
ta
008      
151005s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.msec.2012.08.039 $2 doi
035    __
$a (PubMed)25428071
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Lovětinská-Šlamborová, Irena, $u Centre for Nanomaterials, Advanced Technologies and Innovations, Studentska 1402/2, 461 17 Liberec 1, Czech Republic. $d 1965- $7 xx0259910
245    10
$a New type of protective hybrid and nanocomposite hybrid coatings containing silver and copper with an excellent antibacterial effect especially against MRSA / $c I. Šlamborová, V. Zajícová, J. Karpíšková, P. Exnar, I. Stibor,
520    9_
$a Epidemics spread many types of pathogenic bacterial strains, especially strains of MRSA (Methicillin-resistant Staphylococcus aureus), which are being increasingly reported in many geographical areas [1]. This is becoming to be a serious global problem, particularly in hospitals. Not only are antibiotics proving to be increasingly ineffective but also the bacteria responsible for more than 70% of hospital-acquired bacterial infections are resistant to at least one of the drugs commonly used to treat them. In this study, hybrid coating A1 and nanocomposite hybrid coating A2 based on TMSPM (3-(trimethoxysilyl)propyl methacrylate, MMA (methyl methacrylate), TEOS (tetraethyl orthosilicate) and IPTI (titanium isopropoxide) containing silver and copper ions with or without nanoparticles of titanium dioxide were prepared by the sol-gel method. They were deposited on glass, poly(methyl methacrylate) and cotton using dip-coating or spin-coating, and then cured at 150 °C for 3 h or, in the case of poly(methyl methacrylate), at 100 °C for 4.5 h. The morphology and microstructure of these hybrid coatings were examined by SEM. The abrasion resistance was tested using a washability tester and found to depend heavily on the curing temperature. Seven types of bacterial strains were used to determine the profile of antibacterial activity, namely Escherichia coli, Staphylococcus aureus, Methicillin-resistant Staphylococcus aureus - MRSA (CCM 4223), MRSA-2 (CCM 7112), Acinetobacter baumanii, Pseudomonas aeruginosa, and Proteus vulgaris (according to ALE-G18, CSNI). All the samples were tested by irradiating with either a UV-A or a daylight fluorescent lamp. All types of hybrid coating A1 and nanocomposite hybrid coating A2 were found to possess an excellent antibacterial effect, including against the pathogenic bacterial strains of MRSA, which present a dangerous threat on a global scale.
650    _2
$a Acinetobacter baumannii $x účinky léků $x účinky záření $7 D040981
650    _2
$a antibakteriální látky $x chemie $x farmakologie $7 D000900
650    _2
$a biokompatibilní potahované materiály $x chemie $x farmakologie $7 D020099
650    _2
$a měď $x chemie $7 D003300
650    _2
$a světlo $7 D008027
650    _2
$a methicilin rezistentní Staphylococcus aureus $x účinky léků $x účinky záření $7 D055624
650    _2
$a methylmetakrylát $x chemie $7 D020366
650    _2
$a nanokompozity $x chemie $7 D053761
650    _2
$a organokovové sloučeniny $x chemie $7 D009942
650    _2
$a Proteus vulgaris $x účinky léků $x účinky záření $7 D011514
650    _2
$a Pseudomonas aeruginosa $x účinky léků $x účinky záření $7 D011550
650    _2
$a silany $x chemie $7 D012821
650    _2
$a stříbro $x chemie $7 D012834
650    _2
$a ultrafialové záření $7 D014466
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Zajícová, Veronika $u Centre for Nanomaterials, Advanced Technologies and Innovations, Studentska 1402/2, 461 17 Liberec 1, Czech Republic. Electronic address: veronika.zajicova@tul.cz.
700    1_
$a Karpíšková, Jana $u Institute of Novel Technologies and Applied Informatics, Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Studentska 2, 461 17 Liberec 1, Czech Republic.
700    1_
$a Exnar, Petr $u Centre for Nanomaterials, Advanced Technologies and Innovations, Studentska 1402/2, 461 17 Liberec 1, Czech Republic.
700    1_
$a Stibor, Ivan $u Centre for Nanomaterials, Advanced Technologies and Innovations, Studentska 1402/2, 461 17 Liberec 1, Czech Republic.
773    0_
$w MED00184559 $t Materials science & engineering. C, Materials for biological applications. Materials for biological applications $x 1873-0191 $g Roč. 33, č. 1 (2013), s. 265-73
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25428071 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20151005 $b ABA008
991    __
$a 20210427133312 $b ABA008
999    __
$a ok $b bmc $g 1092993 $s 915243
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 33 $c 1 $d 265-73 $e 20120906 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559 $o Materials for biological applications
LZP    __
$a Pubmed-20151005

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...