-
Je něco špatně v tomto záznamu ?
Interfraction variation in prostate cancer - analysis of 11726 cone-beam CT
M. Dolezel, P. Slezak, K. Odrazka, J. Vanasek, A. Hlavka, V. Ulrych, J. Stuk, I. Waczulikova, I. Hartmann,
Jazyk angličtina Země Řecko
Typ dokumentu časopisecké články
PubMed
26416060
Knihovny.cz E-zdroje
- MeSH
- lidé MeSH
- nádory prostaty radiografie radioterapie MeSH
- počítačová tomografie s kuželovým svazkem * MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: To investigate the setup margins in prostate cancer treatment without using daily online repositioning methods. METHODS: We analysed the data from patients treated with curative-intend radiotherapy. Each patient underwent a series of pretreatment online localizations during daily setup using conebeam CT. The skin-prostate shifts and bone-prostate shifts were recorded in anteroposterior (AP), craniocaudal (CC), and laterolateral (LL)direction. The safety margins based on van Herk equation (2.5Σ+0.7σ) were calculated and the correlations between margins and various patient characteristics and prostate locations were investigated. RESULTS: A total of 307 patients were included, representing 11,726 localisations resulting in 70,356 shifts. The man skin-prostate setup inaccuracy was 0.8 ± 5.4mm in AP, 1.3 ± 4.8mm for CC, and 0.1 ± 5.6mm in LL direction. The man bone-prostate setup inaccuracy was 0.4 ± 3.3mm in AP, 0.1 ± 2.5mm for CC, and 0.1 ± 1.4mm in LL direction. According to van Herk equation, clinical target volume (CTV)-planning target volume (PTV) margins of 11.4, 10.6, and 11.8 mm (AP, CC, and LL, respectively) would be required for setup using skin markers and margins of 7.0, 4.7, and 2.1mm would be necessary for setup using bone structures. The average rectal area < 11cm(2) and volume of bladder > 300 cm(3) were associated with smaller CTV-PTV margins for setup using bone structures. The largest margins (15.8 mm in LL direction) were needed in patients with body mass index (BMI) > 35 using skin markers. CONCLUSIONS: Our results confirm that the commonly used CTV-PTV margins are inadequate.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000027
- 003
- CZ-PrNML
- 005
- 20160126093241.0
- 007
- ta
- 008
- 160108s2015 gr f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)26416060
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gr
- 100 1_
- $a Dolezel, Martin $u Oncology Centre, Multiscan & Pardubice Regional Hospital, Pardubice, Czech Republic.
- 245 10
- $a Interfraction variation in prostate cancer - analysis of 11726 cone-beam CT / $c M. Dolezel, P. Slezak, K. Odrazka, J. Vanasek, A. Hlavka, V. Ulrych, J. Stuk, I. Waczulikova, I. Hartmann,
- 520 9_
- $a PURPOSE: To investigate the setup margins in prostate cancer treatment without using daily online repositioning methods. METHODS: We analysed the data from patients treated with curative-intend radiotherapy. Each patient underwent a series of pretreatment online localizations during daily setup using conebeam CT. The skin-prostate shifts and bone-prostate shifts were recorded in anteroposterior (AP), craniocaudal (CC), and laterolateral (LL)direction. The safety margins based on van Herk equation (2.5Σ+0.7σ) were calculated and the correlations between margins and various patient characteristics and prostate locations were investigated. RESULTS: A total of 307 patients were included, representing 11,726 localisations resulting in 70,356 shifts. The man skin-prostate setup inaccuracy was 0.8 ± 5.4mm in AP, 1.3 ± 4.8mm for CC, and 0.1 ± 5.6mm in LL direction. The man bone-prostate setup inaccuracy was 0.4 ± 3.3mm in AP, 0.1 ± 2.5mm for CC, and 0.1 ± 1.4mm in LL direction. According to van Herk equation, clinical target volume (CTV)-planning target volume (PTV) margins of 11.4, 10.6, and 11.8 mm (AP, CC, and LL, respectively) would be required for setup using skin markers and margins of 7.0, 4.7, and 2.1mm would be necessary for setup using bone structures. The average rectal area < 11cm(2) and volume of bladder > 300 cm(3) were associated with smaller CTV-PTV margins for setup using bone structures. The largest margins (15.8 mm in LL direction) were needed in patients with body mass index (BMI) > 35 using skin markers. CONCLUSIONS: Our results confirm that the commonly used CTV-PTV margins are inadequate.
- 650 12
- $a počítačová tomografie s kuželovým svazkem $7 D054893
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a nádory prostaty $x radiografie $x radioterapie $7 D011471
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Slezak, Peter
- 700 1_
- $a Odrazka, Karel
- 700 1_
- $a Vanasek, Jaroslav
- 700 1_
- $a Hlavka, Ales
- 700 1_
- $a Ulrych, Vit
- 700 1_
- $a Stuk, Jan
- 700 1_
- $a Waczulikova, Iveta
- 700 1_
- $a Hartmann, Igor
- 773 0_
- $w MED00005361 $t Journal of B.U.ON. official journal of the Balkan Union of Oncology $x 1107-0625 $g Roč. 20, č. 4 (2015), s. 1081-7
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26416060 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160126093404 $b ABA008
- 999 __
- $a ok $b bmc $g 1102308 $s 924233
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 20 $c 4 $d 1081-7 $i 1107-0625 $m Journal of Balkan Union of Oncology $n J BUON $x MED00005361
- LZP __
- $a Pubmed-20160108