• Je něco špatně v tomto záznamu ?

Detection of biomarkers for inflammatory diseases by an electrochemical immunoassay: the case of neopterin

S. Centi, S. Tombelli, M. Puntoni, C. Domenici, M. Franek, I. Palchetti,

. 2015 ; 134 (-) : 48-53. [pub] 20141104

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16000349

An electrochemical immunoassay for neopterin was developed using recently produced specific antibodies immobilized to protein A-coated magnetic beads in combination with differential pulse voltammetry and screen-printed array of electrodes. Neopterin-alkaline phosphatase conjugate was used as label in a competitive assay format. Multiplexed analysis of neopterin was demonstrated by replacing the traditional ELISA with electrochemical detection and the traditional plastic wells with screen-printed array of electrodes. The optimized electrochemical method, based on polyclonal antibodies, reached a limit of detection of 0.008 ng/mL with an average RSD %=10. Serum samples collected from patients with sepsis, healthy volunteers and other patients without a confirmed clinical diagnosis were also analyzed. The obtained results, compared with those of a commercial ELISA kit, had a significant correlation, showing the possibility to distinguish among the serum samples from ill or healthy subjects.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16000349
003      
CZ-PrNML
005      
20200121092144.0
007      
ta
008      
160108s2015 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2014.10.053 $2 doi
035    __
$a (PubMed)25618639
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Centi, Sonia $u Università degli Studi di Firenze, Dipartimento di Scienze Biomediche, Sperimentali e Cliniche, Viale G. Pieraccini 6, 50139 Firenze, Italy.
245    10
$a Detection of biomarkers for inflammatory diseases by an electrochemical immunoassay: the case of neopterin / $c S. Centi, S. Tombelli, M. Puntoni, C. Domenici, M. Franek, I. Palchetti,
520    9_
$a An electrochemical immunoassay for neopterin was developed using recently produced specific antibodies immobilized to protein A-coated magnetic beads in combination with differential pulse voltammetry and screen-printed array of electrodes. Neopterin-alkaline phosphatase conjugate was used as label in a competitive assay format. Multiplexed analysis of neopterin was demonstrated by replacing the traditional ELISA with electrochemical detection and the traditional plastic wells with screen-printed array of electrodes. The optimized electrochemical method, based on polyclonal antibodies, reached a limit of detection of 0.008 ng/mL with an average RSD %=10. Serum samples collected from patients with sepsis, healthy volunteers and other patients without a confirmed clinical diagnosis were also analyzed. The obtained results, compared with those of a commercial ELISA kit, had a significant correlation, showing the possibility to distinguish among the serum samples from ill or healthy subjects.
650    _2
$a protilátky $x imunologie $7 D000906
650    _2
$a biologické markery $7 D015415
650    12
$a biosenzitivní techniky $7 D015374
650    _2
$a elektrochemické techniky $7 D055664
650    _2
$a elektrody $7 D004566
650    _2
$a lidé $7 D006801
650    _2
$a imobilizované proteiny $x imunologie $7 D055767
650    _2
$a imunoanalýza $7 D007118
650    _2
$a zánět $7 D007249
650    _2
$a neopterin $x analýza $x krev $x imunologie $7 D019798
650    _2
$a sepse $x krev $7 D018805
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Tombelli, Sara $u Istituto di Fisica Applicata "Nello Carrara", Consiglio Nazionale delle Ricerche, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Italy.
700    1_
$a Puntoni, Mariarita $u Istituto di Fisiologia Clinica, Consiglio Nazionale delle Ricerche, Via G. Moruzzi 1, 56124 Pisa, Italy.
700    1_
$a Domenici, Claudio $u Istituto di Fisiologia Clinica, Consiglio Nazionale delle Ricerche, Via G. Moruzzi 1, 56124 Pisa, Italy.
700    1_
$a Franek, Milan $u Department of Biotechnology, Veterinary Research Institute, Hudcova 70, 621 32 Brno, Czech Republic.
700    1_
$a Palchetti, Ilaria $u Università degli Studi di Firenze, Dipartimento di Chimica, Via della Lastruccia 3, 50019 Sesto Fiorentino, Italy; Istituto di Biochimica delle Proteine, Via P. Castellino 111, 80131 Napoli, Italy. Electronic address: ilaria.palchetti@unifi.it.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 134, č. - (2015), s. 48-53
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25618639 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160108 $b ABA008
991    __
$a 20200121092521 $b ABA008
999    __
$a ok $b bmc $g 1102630 $s 924555
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 134 $c - $d 48-53 $e 20141104 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20160108

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...