Narrow-bore core-shell particles and monolithic columns in the analysis of silybin diastereoisomers

P. Marhol, R. Gažák, P. Bednář, V. Křen,

. 2011 ; 34 (16-17) : 2206-13. [pub] 20110627

Jazyk angličtina Země Německo

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16000831

Two chromatographic narrow-bore columns, a novel 2.6 μm particle-packed Kinetex™ C18 core-shell (50×2.1 mm id) and monolithic Chromolith(®) FastGradient RP-18e (50×2 mm id), were evaluated for the analysis of diastereoisomers of the flavonolignans silybin and 23-O-acetylsilybin under isocratic conditions. The main advantages of the core-shell column are markedly higher efficiency (hmin =2.8 versus 5.6 for silybin A) and better peak symmetry. The Kinetex column exhibits only a slight change in the height equivalent of the theoretical plate with a higher linear velocity of the mobile phase. The monolithic column shows notably higher selectivity in terms of selectivity factor (1.21 versus 1.12) in the analysis of critical-pair of diastereoisomers (silybin A and silybin B) and enables shorter run duration (approx. twofold) together with lower backpressure. The resolution power was found to be comparable, but the Kinetex column required a higher pressure of the mobile phase that, together with the higher chance of clogging, can be a disadvantage in the separation of biological samples. Successful baseline separation of silybin diastereoisomers in real pharmaceutical sample on monolithic column was accomplished.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16000831
003      
CZ-PrNML
005      
20160126104038.0
007      
ta
008      
160108s2011 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201100309 $2 doi
035    __
$a (PubMed)21710694
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Marhol, Petr $u Institute of Microbiology, Centre of Biocatalysis and Biotransformation, Academy of Sciences of the Czech Republic, Prague, Czech Republic. marholp@gmail.com.
245    10
$a Narrow-bore core-shell particles and monolithic columns in the analysis of silybin diastereoisomers / $c P. Marhol, R. Gažák, P. Bednář, V. Křen,
520    9_
$a Two chromatographic narrow-bore columns, a novel 2.6 μm particle-packed Kinetex™ C18 core-shell (50×2.1 mm id) and monolithic Chromolith(®) FastGradient RP-18e (50×2 mm id), were evaluated for the analysis of diastereoisomers of the flavonolignans silybin and 23-O-acetylsilybin under isocratic conditions. The main advantages of the core-shell column are markedly higher efficiency (hmin =2.8 versus 5.6 for silybin A) and better peak symmetry. The Kinetex column exhibits only a slight change in the height equivalent of the theoretical plate with a higher linear velocity of the mobile phase. The monolithic column shows notably higher selectivity in terms of selectivity factor (1.21 versus 1.12) in the analysis of critical-pair of diastereoisomers (silybin A and silybin B) and enables shorter run duration (approx. twofold) together with lower backpressure. The resolution power was found to be comparable, but the Kinetex column required a higher pressure of the mobile phase that, together with the higher chance of clogging, can be a disadvantage in the separation of biological samples. Successful baseline separation of silybin diastereoisomers in real pharmaceutical sample on monolithic column was accomplished.
650    _2
$a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
650    _2
$a syntetické pryskyřice $x chemie $7 D012117
650    _2
$a silymarin $x chemie $x izolace a purifikace $7 D012838
650    _2
$a stereoizomerie $7 D013237
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Gažák, Radek
700    1_
$a Bednář, Petr
700    1_
$a Křen, Vladimír
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 34, č. 16-17 (2011), s. 2206-13
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21710694 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160108 $b ABA008
991    __
$a 20160126104201 $b ABA008
999    __
$a ok $b bmc $g 1103112 $s 925037
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 34 $c 16-17 $d 2206-13 $e 20110627 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$a Pubmed-20160108

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...