Je něco špatně v tomto záznamu ?
Modern evaluation of liquisolid systems with varying amounts of liquid phase prepared using two different methods
B. Vraníková, J. Gajdziok, D. Vetchý,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
Free Medical Journals
od 2013
PubMed Central
od 2013
Europe PubMed Central
od 2013
ProQuest Central
od 2013
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2012-12-04
Open Access Digital Library
od 2013-01-01
CINAHL Plus with Full Text (EBSCOhost)
od 2013-01-01
Medline Complete (EBSCOhost)
od 2013-01-01
Health & Medicine (ProQuest)
od 2013
Wiley-Blackwell Open Access Titles
od 2001
ROAD: Directory of Open Access Scholarly Resources
od 2013
PubMed
26075249
DOI
10.1155/2015/608435
Knihovny.cz E-zdroje
- MeSH
- kyseliny stearové chemie MeSH
- laktosa chemie MeSH
- lidé MeSH
- polyethylenglykoly chemie MeSH
- rosuvastatin kalcium chemie MeSH
- silikáty chemie MeSH
- sloučeniny hliníku chemie MeSH
- sloučeniny hořčíku chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Liquisolid systems are an innovative dosage form used for enhancing dissolution rate and improving in vivo bioavailability of poorly soluble drugs. These formulations require specific evaluation methods for their quality assurance (e.g., evaluation of angle of slide, contact angle, or water absorption ratio). The presented study is focused on the preparation, modern in vitro testing, and evaluation of differences of liquisolid systems containing varying amounts of a drug in liquid state (polyethylene glycol 400 solution of rosuvastatin) in relation to an aluminometasilicate carrier (Neusilin US2). Liquisolid powders used for the formulation of final tablets were prepared using two different methods: simple blending and spraying of drug solution onto a carrier in fluid bed equipment. The obtained results imply that the amount of liquid phase in relation to carrier material had an effect on the hardness, friability, and disintegration of tablets, as well as their height. The use of spraying technique enhanced flow properties of the prepared mixtures, increased hardness values, decreased friability, and improved homogeneity of the final dosage form.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010103
- 003
- CZ-PrNML
- 005
- 20181011123703.0
- 007
- ta
- 008
- 160408s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1155/2015/608435 $2 doi
- 024 7_
- $a 10.1155/2015/608435 $2 doi
- 035 __
- $a (PubMed)26075249
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Vraníková, Barbora, $d 1987- $7 xx0228025 $u Department of Pharmaceutics, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Palackého 1/3, 612 42 Brno, Czech Republic.
- 245 10
- $a Modern evaluation of liquisolid systems with varying amounts of liquid phase prepared using two different methods / $c B. Vraníková, J. Gajdziok, D. Vetchý,
- 520 9_
- $a Liquisolid systems are an innovative dosage form used for enhancing dissolution rate and improving in vivo bioavailability of poorly soluble drugs. These formulations require specific evaluation methods for their quality assurance (e.g., evaluation of angle of slide, contact angle, or water absorption ratio). The presented study is focused on the preparation, modern in vitro testing, and evaluation of differences of liquisolid systems containing varying amounts of a drug in liquid state (polyethylene glycol 400 solution of rosuvastatin) in relation to an aluminometasilicate carrier (Neusilin US2). Liquisolid powders used for the formulation of final tablets were prepared using two different methods: simple blending and spraying of drug solution onto a carrier in fluid bed equipment. The obtained results imply that the amount of liquid phase in relation to carrier material had an effect on the hardness, friability, and disintegration of tablets, as well as their height. The use of spraying technique enhanced flow properties of the prepared mixtures, increased hardness values, decreased friability, and improved homogeneity of the final dosage form.
- 650 _2
- $a sloučeniny hliníku $x chemie $7 D017607
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a laktosa $x chemie $7 D007785
- 650 _2
- $a sloučeniny hořčíku $x chemie $7 D017616
- 650 _2
- $a polyethylenglykoly $x chemie $7 D011092
- 650 _2
- $a rosuvastatin kalcium $x chemie $7 D000068718
- 650 _2
- $a silikáty $x chemie $7 D017640
- 650 _2
- $a kyseliny stearové $x chemie $7 D013229
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Gajdziok, Jan $u Department of Pharmaceutics, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Palackého 1/3, 612 42 Brno, Czech Republic.
- 700 1_
- $a Vetchý, David $u Department of Pharmaceutics, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Palackého 1/3, 612 42 Brno, Czech Republic.
- 773 0_
- $w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2015, č. - (2015), s. 608435
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26075249 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20181011124154 $b ABA008
- 999 __
- $a ok $b bmc $g 1113532 $s 934471
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 2015 $c - $d 608435 $e 20150517 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
- LZP __
- $a Pubmed-20160408