Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry
V. Shestivska, SS. Antonowicz, K. Dryahina, J. Kubišta, D. Smith, P. Španěl,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
PubMed
26044275
DOI
10.1002/rcm.7198
Knihovny.cz E-zdroje
- MeSH
- hmotnostní spektrometrie metody MeSH
- lidé MeSH
- malondialdehyd chemie MeSH
- nádorové buněčné linie MeSH
- pára analýza MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí metody MeSH
- vlhkost MeSH
- vzduch analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
RATIONALE: It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presence of water vapour are required. METHODS: The SIFT technique has been used to determine the rate coefficients and ion product distributions for the reactions of H3O(+), NO(+) and O2 (+•) with gas-phase MDA. In support of the SIFT-MS analysis of MDA, solid-phase microextraction, SPME, coupled with gas chromatography/mass spectrometry, GC/MS, has been used to confirm the identification of MDA. RESULTS: The primary product ions have been identified for the reactions of H3O(+), NO(+) and O2 (+•) with MDA and the formation of their hydrates formed in humid samples is described. The following combinations of reagent and the analyte ions (given as m/z values) have been adopted for SIFT-MS analyses of MDA in the gas phase: H3O(+): 109; NO(+): 89, 102; O2 (+•): 72, 90, 108, 126. The detection and quantification of MDA released by a cell culture by SIFT-MS are demonstrated. CONCLUSIONS: This detailed study has provided the kinetics data required for the SIFT-MS analysis of MDA in humid air, including exhaled breath and the headspace of liquid-phase biogenic media. The detection and quantification by SIFT-MS of MDA released by a cell culture are demonstrated.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010130
- 003
- CZ-PrNML
- 005
- 20160418103823.0
- 007
- ta
- 008
- 160408s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/rcm.7198 $2 doi
- 024 7_
- $a 10.1002/rcm.7198 $2 doi
- 035 __
- $a (PubMed)26044275
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Shestivska, Violetta $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
- 245 10
- $a Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry / $c V. Shestivska, SS. Antonowicz, K. Dryahina, J. Kubišta, D. Smith, P. Španěl,
- 520 9_
- $a RATIONALE: It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presence of water vapour are required. METHODS: The SIFT technique has been used to determine the rate coefficients and ion product distributions for the reactions of H3O(+), NO(+) and O2 (+•) with gas-phase MDA. In support of the SIFT-MS analysis of MDA, solid-phase microextraction, SPME, coupled with gas chromatography/mass spectrometry, GC/MS, has been used to confirm the identification of MDA. RESULTS: The primary product ions have been identified for the reactions of H3O(+), NO(+) and O2 (+•) with MDA and the formation of their hydrates formed in humid samples is described. The following combinations of reagent and the analyte ions (given as m/z values) have been adopted for SIFT-MS analyses of MDA in the gas phase: H3O(+): 109; NO(+): 89, 102; O2 (+•): 72, 90, 108, 126. The detection and quantification of MDA released by a cell culture by SIFT-MS are demonstrated. CONCLUSIONS: This detailed study has provided the kinetics data required for the SIFT-MS analysis of MDA in humid air, including exhaled breath and the headspace of liquid-phase biogenic media. The detection and quantification by SIFT-MS of MDA released by a cell culture are demonstrated.
- 650 _2
- $a vzduch $x analýza $7 D000388
- 650 _2
- $a nádorové buněčné linie $7 D045744
- 650 _2
- $a plynová chromatografie s hmotnostně spektrometrickou detekcí $x metody $7 D008401
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a vlhkost $7 D006813
- 650 _2
- $a malondialdehyd $x chemie $7 D008315
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a pára $x analýza $7 D013227
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Antonowicz, Stefan S $u Department of Surgery and Cancer, Imperial College London, St. Mary's Hospital, Praed Street, London, W2 1NY, UK. $7 gn_A_00007509
- 700 1_
- $a Dryahina, Kseniya $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
- 700 1_
- $a Kubišta, Jiří $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
- 700 1_
- $a Smith, David $u Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent, ST4 7QB, UK.
- 700 1_
- $a Španěl, Patrik $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic. Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent, ST4 7QB, UK.
- 773 0_
- $w MED00004050 $t Rapid communications in mass spectrometry RCM $x 1097-0231 $g Roč. 29, č. 11 (2015), s. 1069-79
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26044275 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20160418103911 $b ABA008
- 999 __
- $a ok $b bmc $g 1113559 $s 934498
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 29 $c 11 $d 1069-79 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
- LZP __
- $a Pubmed-20160408