• Je něco špatně v tomto záznamu ?

Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry

V. Shestivska, SS. Antonowicz, K. Dryahina, J. Kubišta, D. Smith, P. Španěl,

. 2015 ; 29 (11) : 1069-79.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16010130

RATIONALE: It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presence of water vapour are required. METHODS: The SIFT technique has been used to determine the rate coefficients and ion product distributions for the reactions of H3O(+), NO(+) and O2 (+•) with gas-phase MDA. In support of the SIFT-MS analysis of MDA, solid-phase microextraction, SPME, coupled with gas chromatography/mass spectrometry, GC/MS, has been used to confirm the identification of MDA. RESULTS: The primary product ions have been identified for the reactions of H3O(+), NO(+) and O2 (+•) with MDA and the formation of their hydrates formed in humid samples is described. The following combinations of reagent and the analyte ions (given as m/z values) have been adopted for SIFT-MS analyses of MDA in the gas phase: H3O(+): 109; NO(+): 89, 102; O2 (+•): 72, 90, 108, 126. The detection and quantification of MDA released by a cell culture by SIFT-MS are demonstrated. CONCLUSIONS: This detailed study has provided the kinetics data required for the SIFT-MS analysis of MDA in humid air, including exhaled breath and the headspace of liquid-phase biogenic media. The detection and quantification by SIFT-MS of MDA released by a cell culture are demonstrated.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16010130
003      
CZ-PrNML
005      
20160418103823.0
007      
ta
008      
160408s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/rcm.7198 $2 doi
024    7_
$a 10.1002/rcm.7198 $2 doi
035    __
$a (PubMed)26044275
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Shestivska, Violetta $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
245    10
$a Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry / $c V. Shestivska, SS. Antonowicz, K. Dryahina, J. Kubišta, D. Smith, P. Španěl,
520    9_
$a RATIONALE: It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presence of water vapour are required. METHODS: The SIFT technique has been used to determine the rate coefficients and ion product distributions for the reactions of H3O(+), NO(+) and O2 (+•) with gas-phase MDA. In support of the SIFT-MS analysis of MDA, solid-phase microextraction, SPME, coupled with gas chromatography/mass spectrometry, GC/MS, has been used to confirm the identification of MDA. RESULTS: The primary product ions have been identified for the reactions of H3O(+), NO(+) and O2 (+•) with MDA and the formation of their hydrates formed in humid samples is described. The following combinations of reagent and the analyte ions (given as m/z values) have been adopted for SIFT-MS analyses of MDA in the gas phase: H3O(+): 109; NO(+): 89, 102; O2 (+•): 72, 90, 108, 126. The detection and quantification of MDA released by a cell culture by SIFT-MS are demonstrated. CONCLUSIONS: This detailed study has provided the kinetics data required for the SIFT-MS analysis of MDA in humid air, including exhaled breath and the headspace of liquid-phase biogenic media. The detection and quantification by SIFT-MS of MDA released by a cell culture are demonstrated.
650    _2
$a vzduch $x analýza $7 D000388
650    _2
$a nádorové buněčné linie $7 D045744
650    _2
$a plynová chromatografie s hmotnostně spektrometrickou detekcí $x metody $7 D008401
650    _2
$a lidé $7 D006801
650    _2
$a vlhkost $7 D006813
650    _2
$a malondialdehyd $x chemie $7 D008315
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a pára $x analýza $7 D013227
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Antonowicz, Stefan S $u Department of Surgery and Cancer, Imperial College London, St. Mary's Hospital, Praed Street, London, W2 1NY, UK. $7 gn_A_00007509
700    1_
$a Dryahina, Kseniya $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
700    1_
$a Kubišta, Jiří $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic.
700    1_
$a Smith, David $u Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent, ST4 7QB, UK.
700    1_
$a Španěl, Patrik $u J. Heyrovsky Institute of Physical Chemistry of Science, Academy of Science of the Czech Republic, Dolejškova 3, 18223, Prague 8, Czech Republic. Institute for Science and Technology in Medicine, School of Medicine, Keele University, Thornburrow Drive, Hartshill, Stoke-on-Trent, ST4 7QB, UK.
773    0_
$w MED00004050 $t Rapid communications in mass spectrometry RCM $x 1097-0231 $g Roč. 29, č. 11 (2015), s. 1069-79
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26044275 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20160418103911 $b ABA008
999    __
$a ok $b bmc $g 1113559 $s 934498
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 29 $c 11 $d 1069-79 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a Pubmed-20160408

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...