Evaluation of fibrinogen concentrates and prothrombin complex concentrates on coagulation changes in a hypothermic in vitro model using thromboelastometry and thromboelastography
M. Durila, P. Lukáš, M. Astraverkhava, T. Vymazal,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, multicentrická studie, práce podpořená grantem
- MeSH
- biologické modely * MeSH
- dospělí MeSH
- fibrinogen farmakologie MeSH
- hemokoagulace účinky léků MeSH
- koagulační faktory farmakologie MeSH
- lidé MeSH
- rotace MeSH
- terapeutická hypotermie * MeSH
- tromboelastografie metody MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Hypothermic coagulopathy is very challenging in bleeding trauma patients. Therefore, we decided to evaluate the efficacy of fibrinogen and prothrombin complex in 30°C hypothermia in vitro to investigate if higher levels of fibrinogen and prothrombin complex concentrate can compensate for the hypothermic effect on coagulation as measured by thromboelastometry/thromboelastography. METHODS: Blood samples were obtained from 12 healthy volunteers (six men and six women) in our study. Measurements were performed at 37°C and 30°C simultaneously, then at 30°C with adding fibrinogen and prothrombin complex and in the last step samples with added coagulation factors were warmed back to 37°C. RESULTS: We found that 30°C hypothermic coagulopathy can be detected both by thromboelastometry and thromboelastography. Hypothermic coagulopathy can be restored by fibrinogen to the point where the results do not significantly differ from 37°C values (p > 0.05). After warming the sample with fibrinogen to 37°C, the thrombodynamic potential index was not significantly different from baseline (p > 0.05), although there was a trend to prothrombotic status. The addition of prothrombin complex concentrate to 30°C hypothermic sample was not able to correct hypothermic coagulopathy in vitro. CONCLUSIONS: Coagulopathy caused by the 30°C hypothermia in vitro model can be corrected by fibrinogen concentrate compared to prothrombin complex concentrate. In spite of a tendency to prothrombotic status, this was not significant with the use of the recommended dose of fibrinogen even after warming the blood to 37°C. However, measurement performed at 37°C seems to be safer than at 30°C.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010302
- 003
- CZ-PrNML
- 005
- 20160418105528.0
- 007
- ta
- 008
- 160408s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3109/00365513.2015.1031694 $2 doi
- 024 7_
- $a 10.3109/00365513.2015.1031694 $2 doi
- 035 __
- $a (PubMed)25892117
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Durila, Miroslav $u Department of Anaesthesiology and Intensive Care Medicine, Second Faculty of Medicine, Charles University in Prague, Motol University Hospital , Prague , Czech Republic.
- 245 10
- $a Evaluation of fibrinogen concentrates and prothrombin complex concentrates on coagulation changes in a hypothermic in vitro model using thromboelastometry and thromboelastography / $c M. Durila, P. Lukáš, M. Astraverkhava, T. Vymazal,
- 520 9_
- $a BACKGROUND: Hypothermic coagulopathy is very challenging in bleeding trauma patients. Therefore, we decided to evaluate the efficacy of fibrinogen and prothrombin complex in 30°C hypothermia in vitro to investigate if higher levels of fibrinogen and prothrombin complex concentrate can compensate for the hypothermic effect on coagulation as measured by thromboelastometry/thromboelastography. METHODS: Blood samples were obtained from 12 healthy volunteers (six men and six women) in our study. Measurements were performed at 37°C and 30°C simultaneously, then at 30°C with adding fibrinogen and prothrombin complex and in the last step samples with added coagulation factors were warmed back to 37°C. RESULTS: We found that 30°C hypothermic coagulopathy can be detected both by thromboelastometry and thromboelastography. Hypothermic coagulopathy can be restored by fibrinogen to the point where the results do not significantly differ from 37°C values (p > 0.05). After warming the sample with fibrinogen to 37°C, the thrombodynamic potential index was not significantly different from baseline (p > 0.05), although there was a trend to prothrombotic status. The addition of prothrombin complex concentrate to 30°C hypothermic sample was not able to correct hypothermic coagulopathy in vitro. CONCLUSIONS: Coagulopathy caused by the 30°C hypothermia in vitro model can be corrected by fibrinogen concentrate compared to prothrombin complex concentrate. In spite of a tendency to prothrombotic status, this was not significant with the use of the recommended dose of fibrinogen even after warming the blood to 37°C. However, measurement performed at 37°C seems to be safer than at 30°C.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a hemokoagulace $x účinky léků $7 D001777
- 650 _2
- $a koagulační faktory $x farmakologie $7 D001779
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a fibrinogen $x farmakologie $7 D005340
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a terapeutická hypotermie $7 D007036
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a biologické modely $7 D008954
- 650 _2
- $a rotace $7 D012399
- 650 _2
- $a tromboelastografie $x metody $7 D013916
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a multicentrická studie $7 D016448
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Lukáš, Pavel
- 700 1_
- $a Astraverkhava, Marta $7 gn_A_00009617
- 700 1_
- $a Vymazal, Tomáš
- 773 0_
- $w MED00010597 $t Scandinavian journal of clinical and laboratory investigation $x 1502-7686 $g Roč. 75, č. 5 (2015), s. 407-14
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25892117 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20160418105615 $b ABA008
- 999 __
- $a ok $b bmc $g 1113731 $s 934670
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 75 $c 5 $d 407-14 $e 20150418 $i 1502-7686 $m Scandinavian journal of clinical & laboratory investigation $n Scand J Clin Lab Invest $x MED00010597
- LZP __
- $a Pubmed-20160408