-
Je něco špatně v tomto záznamu ?
3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein
Z. Heger, J. Zitka, N. Cernei, S. Krizkova, M. Sztalmachova, P. Kopel, M. Masarik, P. Hodek, O. Zitka, V. Adam, R. Kizek,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NT14337
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
Medline Complete (EBSCOhost)
od 2012-10-01 do Před 1 rokem
PubMed
25735231
DOI
10.1002/elps.201400559
Knihovny.cz E-zdroje
- MeSH
- 3D tisk * MeSH
- biosenzitivní techniky MeSH
- dimethylpolysiloxany chemie MeSH
- fluorescence MeSH
- kovové nanočástice MeSH
- kvantové tečky MeSH
- lidé MeSH
- magnetismus MeSH
- metalothionein analýza MeSH
- nádorové buněčné linie MeSH
- nádory patologie MeSH
- sloučeniny kadmia chemie MeSH
- telur chemie MeSH
- zlato chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Currently, metallothioneins (MTs) are extensively investigated as the molecular biomarkers and the significant positive association of the MT amount was observed in tumorous versus healthy tissue of various types of malignant tumors, including head and neck cancer. Thus, we proposed a biosensor with fluorescence detection, comprising paramagnetic nanoparticles (nanomaghemite core with gold nanoparticles containing shell) for the magnetic separation of MT, based on affinity of its sulfhydryl groups toward gold. Biosensor was crafted from PDMS combined with technology of 3D printing and contained reservoir with volume of 50 μL linked to input (sample/detection components and washing/immunobuffer) and output (waste). For the immunolabeling of immobilized MT anti-MT antibodies conjugated to CdTe quantum dots through synthetic heptapeptide were employed. After optimization of fundamental conditions of the immunolabeling (120 min, 20°C, and 1250 rpm) we performed it on a surface of paramagnetic nanoparticles in the biosensor reservoir, with evaluation of fluorescence of quantum dots (λexc 400 nm, and λem 555 nm). The developed biosensor was applied for quantification of MT in cell lines derived from spinocellular carcinoma (cell line 122P-N) and fibroblasts (122P-F) and levels of the biomarker were found to be about 90 nM in tumor cells and 37 nM in fibroblasts. The proposed system is able to work with low volumes (< 100 μL), with low acquisition costs and high portability.
Department of Biochemistry Faculty of Science Charles University Prague Prague Czech Republic
Department of Chemistry and Biochemistry Mendel University Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010498
- 003
- CZ-PrNML
- 005
- 20191113090903.0
- 007
- ta
- 008
- 160408s2015 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201400559 $2 doi
- 024 7_
- $a 10.1002/elps.201400559 $2 doi
- 035 __
- $a (PubMed)25735231
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Heger, Zbyněk $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $7 xx0276759
- 245 10
- $a 3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein / $c Z. Heger, J. Zitka, N. Cernei, S. Krizkova, M. Sztalmachova, P. Kopel, M. Masarik, P. Hodek, O. Zitka, V. Adam, R. Kizek,
- 520 9_
- $a Currently, metallothioneins (MTs) are extensively investigated as the molecular biomarkers and the significant positive association of the MT amount was observed in tumorous versus healthy tissue of various types of malignant tumors, including head and neck cancer. Thus, we proposed a biosensor with fluorescence detection, comprising paramagnetic nanoparticles (nanomaghemite core with gold nanoparticles containing shell) for the magnetic separation of MT, based on affinity of its sulfhydryl groups toward gold. Biosensor was crafted from PDMS combined with technology of 3D printing and contained reservoir with volume of 50 μL linked to input (sample/detection components and washing/immunobuffer) and output (waste). For the immunolabeling of immobilized MT anti-MT antibodies conjugated to CdTe quantum dots through synthetic heptapeptide were employed. After optimization of fundamental conditions of the immunolabeling (120 min, 20°C, and 1250 rpm) we performed it on a surface of paramagnetic nanoparticles in the biosensor reservoir, with evaluation of fluorescence of quantum dots (λexc 400 nm, and λem 555 nm). The developed biosensor was applied for quantification of MT in cell lines derived from spinocellular carcinoma (cell line 122P-N) and fibroblasts (122P-F) and levels of the biomarker were found to be about 90 nM in tumor cells and 37 nM in fibroblasts. The proposed system is able to work with low volumes (< 100 μL), with low acquisition costs and high portability.
- 650 _2
- $a biosenzitivní techniky $7 D015374
- 650 _2
- $a sloučeniny kadmia $x chemie $7 D019187
- 650 _2
- $a nádorové buněčné linie $7 D045744
- 650 _2
- $a dimethylpolysiloxany $x chemie $7 D004129
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a zlato $x chemie $7 D006046
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetismus $7 D008280
- 650 _2
- $a kovové nanočástice $7 D053768
- 650 _2
- $a metalothionein $x analýza $7 D008668
- 650 _2
- $a nádory $x patologie $7 D009369
- 650 12
- $a 3D tisk $7 D066330
- 650 _2
- $a kvantové tečky $7 D045663
- 650 _2
- $a telur $x chemie $7 D013691
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Zítka, Jan $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. $7 _AN082271
- 700 1_
- $a Cernei, Natalia $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $7 _AN063287
- 700 1_
- $a Křížková, Soňa, $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $d 1981- $7 xx0105812
- 700 1_
- $a Sztalmachová, Markéta $u Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. Department of Pathological Physiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic. $7 xx0146032
- 700 1_
- $a Kopel, Pavel, $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $d 1965- $7 mzk2005300913
- 700 1_
- $a Masařík, Michal $u Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. Department of Pathological Physiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic. $7 xx0104244
- 700 1_
- $a Hodek, Petr, $u Department of Biochemistry, Faculty of Science, Charles University in Prague, Prague, Czech Republic. $d 1959- $7 jo2003186329
- 700 1_
- $a Zítka, Ondřej, $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $d 1985- $7 xx0116134
- 700 1_
- $a Adam, Vojtěch $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $7 xx0064599
- 700 1_
- $a Kizek, René, $u Department of Chemistry and Biochemistry, Mendel University, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $d 1972- $7 jn20001005291
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 36, č. 11-12 (2015), s. 1256-1264
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25735231 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20191113091140 $b ABA008
- 999 __
- $a ok $b bmc $g 1113927 $s 934866
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 36 $c 11-12 $d 1256-1264 $e 20150518 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- GRA __
- $a NT14337 $p MZ0
- LZP __
- $a Pubmed-20160408