A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface

D. Choudhury, F. Urban, M. Vrbka, M. Hartl, I. Krupka,

. 2015 ; 45 (-) : 121-131. [pub] 20150209

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16010528

Grantová podpora
NT14267 MZ0 CEP - Centrální evidence projektů

This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16010528
003      
CZ-PrNML
005      
20190708090741.0
007      
ta
008      
160408s2015 ne f 000 0|engg|
009      
AR
024    7_
$a 10.1016/j.jmbbm.2014.11.028 $2 doi
024    7_
$a 10.1016/j.jmbbm.2014.11.028 $2 doi
035    __
$a (PubMed)25704181
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Choudhury, Dipankar $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. Electronic address: Dipankar.choudhury78@gmail.com.
245    12
$a A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface / $c D. Choudhury, F. Urban, M. Vrbka, M. Hartl, I. Krupka,
520    9_
$a This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.
650    12
$a diamant $7 D018130
650    _2
$a tření $7 D017276
650    _2
$a kyčelní kloub $7 D006621
650    12
$a testování materiálů $7 D008422
650    12
$a mechanické jevy $7 D055595
650    12
$a ortopedie $7 D009985
650    12
$a protézy a implantáty $7 D019736
650    _2
$a povrchové vlastnosti $7 D013499
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Urban, Filip $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic.
700    1_
$a Vrbka, Martin, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. $d 1977- $7 mzk2004248591
700    1_
$a Hartl, Martin, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic. $d 1967- $7 mzk2002157052
700    1_
$a Křupka, Ivan, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. $d 1967- $7 mzk2002157050
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 45, č. - (2015), s. 121-131
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25704181 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160408 $b ABA008
991    __
$a 20190708090938 $b ABA008
999    __
$a ok $b bmc $g 1113957 $s 934896
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 45 $c - $d 121-131 $e 20150209 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
GRA    __
$a NT14267 $p MZ0
LZP    __
$a Pubmed-20160408

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...