A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface
D. Choudhury, F. Urban, M. Vrbka, M. Hartl, I. Krupka,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NT14267
MZ0
CEP - Centrální evidence projektů
- MeSH
- diamant * MeSH
- kyčelní kloub MeSH
- mechanické jevy * MeSH
- ortopedie * MeSH
- povrchové vlastnosti MeSH
- protézy a implantáty * MeSH
- testování materiálů * MeSH
- tření MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16010528
- 003
- CZ-PrNML
- 005
- 20190708090741.0
- 007
- ta
- 008
- 160408s2015 ne f 000 0|engg|
- 009
- AR
- 024 7_
- $a 10.1016/j.jmbbm.2014.11.028 $2 doi
- 024 7_
- $a 10.1016/j.jmbbm.2014.11.028 $2 doi
- 035 __
- $a (PubMed)25704181
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Choudhury, Dipankar $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. Electronic address: Dipankar.choudhury78@gmail.com.
- 245 12
- $a A novel tribological study on DLC-coated micro-dimpled orthopedics implant interface / $c D. Choudhury, F. Urban, M. Vrbka, M. Hartl, I. Krupka,
- 520 9_
- $a This study investigates a tribological performance of diamond like carbon (DLC) coated micro dimpled prosthesis heads against ceramic cups in a novel pendulum hip joint simulator. The simulator enables determining friction coefficient and viscous effects of a concave shaped specimen interface (conformal contact). Two types of DLC such as hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) and one set of micro dimple (diameter of 300µm, depth of 70µm, and pitch of 900µm) were fabricated on metallic prosthesis heads. The experiment results reveal a significant friction coefficient reduction to the 'dimpled a-C:H/ceramic' prosthesis compared to a 'Metal (CoCr)/ceramic' prosthesis because of their improved material and surface properties and viscous effect. The post-experiment surface analysis displays that the dimpled a-C:H yielded a minor change in the surface roughness, and generated a larger sizes of wear debris (40-200nm sized, equivalent diameter), a size which could be certainly stored in the dimple, thus likely to reducing their possible third body abrasive wear rate. Thus, dimpled a:C-H can be used as a 'metal on ceramic hip joint interface', whereas the simulator can be utilized as an advanced bio-tribometer.
- 650 12
- $a diamant $7 D018130
- 650 _2
- $a tření $7 D017276
- 650 _2
- $a kyčelní kloub $7 D006621
- 650 12
- $a testování materiálů $7 D008422
- 650 12
- $a mechanické jevy $7 D055595
- 650 12
- $a ortopedie $7 D009985
- 650 12
- $a protézy a implantáty $7 D019736
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Urban, Filip $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic.
- 700 1_
- $a Vrbka, Martin, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. $d 1977- $7 mzk2004248591
- 700 1_
- $a Hartl, Martin, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic. $d 1967- $7 mzk2002157052
- 700 1_
- $a Křupka, Ivan, $u Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic; CEITEC-Central European Institute of Technology, Brno University of Technology, Technická 3058/10, 616 00 Brno, Czech Republic. $d 1967- $7 mzk2002157050
- 773 0_
- $w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 45, č. - (2015), s. 121-131
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25704181 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160408 $b ABA008
- 991 __
- $a 20190708090938 $b ABA008
- 999 __
- $a ok $b bmc $g 1113957 $s 934896
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 45 $c - $d 121-131 $e 20150209 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
- GRA __
- $a NT14267 $p MZ0
- LZP __
- $a Pubmed-20160408