-
Something wrong with this record ?
How good is a PCR efficiency estimate: Recommendations for precise and robust qPCR efficiency assessments
D. Svec, A. Tichopad, V. Novosadova, MW. Pfaffl, M. Kubista,
Language English Country Germany
Document type Journal Article
NLK
Free Medical Journals
from 2014
PubMed Central
from 2014 to 2019
Europe PubMed Central
from 2014
Open Access Digital Library
from 2014-01-01
Open Access Digital Library
from 2014-09-01
Open Access Digital Library
from 2014-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2014 to 2019
- Publication type
- Journal Article MeSH
We have examined the imprecision in the estimation of PCR efficiency by means of standard curves based on strategic experimental design with large number of technical replicates. In particular, how robust this estimation is in terms of a commonly varying factors: the instrument used, the number of technical replicates performed and the effect of the volume transferred throughout the dilution series. We used six different qPCR instruments, we performed 1-16 qPCR replicates per concentration and we tested 2-10 μl volume of analyte transferred, respectively. We find that the estimated PCR efficiency varies significantly across different instruments. Using a Monte Carlo approach, we find the uncertainty in the PCR efficiency estimation may be as large as 42.5% (95% CI) if standard curve with only one qPCR replicate is used in 16 different plates. Based on our investigation we propose recommendations for the precise estimation of PCR efficiency: (1) one robust standard curve with at least 3-4 qPCR replicates at each concentration shall be generated, (2) the efficiency is instrument dependent, but reproducibly stable on one platform, and (3) using a larger volume when constructing serial dilution series reduces sampling error and enables calibration across a wider dynamic range.
Faculty of Medicine Pilsen Charles University Pilsen Czech Republic
Institute of Biotechnology Academy of Science of the Czech Republic Prague Czech Republic
Physiology Weihenstephan TUM Technische Universität München Freising Germany
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16019960
- 003
- CZ-PrNML
- 005
- 20160913112050.0
- 007
- ta
- 008
- 160722s2015 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.bdq.2015.01.005 $2 doi
- 024 7_
- $a 10.1016/j.bdq.2015.01.005 $2 doi
- 035 __
- $a (PubMed)27077029
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Svec, David $u Institute of Biotechnology, Academy of Science of the Czech Republic, Prague, Czech Republic; TATAA Biocenter, Gothenburg, Sweden.
- 245 10
- $a How good is a PCR efficiency estimate: Recommendations for precise and robust qPCR efficiency assessments / $c D. Svec, A. Tichopad, V. Novosadova, MW. Pfaffl, M. Kubista,
- 520 9_
- $a We have examined the imprecision in the estimation of PCR efficiency by means of standard curves based on strategic experimental design with large number of technical replicates. In particular, how robust this estimation is in terms of a commonly varying factors: the instrument used, the number of technical replicates performed and the effect of the volume transferred throughout the dilution series. We used six different qPCR instruments, we performed 1-16 qPCR replicates per concentration and we tested 2-10 μl volume of analyte transferred, respectively. We find that the estimated PCR efficiency varies significantly across different instruments. Using a Monte Carlo approach, we find the uncertainty in the PCR efficiency estimation may be as large as 42.5% (95% CI) if standard curve with only one qPCR replicate is used in 16 different plates. Based on our investigation we propose recommendations for the precise estimation of PCR efficiency: (1) one robust standard curve with at least 3-4 qPCR replicates at each concentration shall be generated, (2) the efficiency is instrument dependent, but reproducibly stable on one platform, and (3) using a larger volume when constructing serial dilution series reduces sampling error and enables calibration across a wider dynamic range.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Tichopad, Ales $u Faculty of Medicine Pilsen, Charles University, Pilsen, Czech Republic.
- 700 1_
- $a Novosadova, Vendula $u Institute of Biotechnology, Academy of Science of the Czech Republic, Prague, Czech Republic; TATAA Biocenter, Gothenburg, Sweden.
- 700 1_
- $a Pfaffl, Michael W $u Physiology Weihenstephan, TUM - Technische Universität München, Freising, Germany.
- 700 1_
- $a Kubista, Mikael $u Institute of Biotechnology, Academy of Science of the Czech Republic, Prague, Czech Republic; TATAA Biocenter, Gothenburg, Sweden.
- 773 0_
- $w MED00189513 $t Biomolecular detection and quantification $x 2214-7535 $g Roč. 3, č. - (2015), s. 9-16
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27077029 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160722 $b ABA008
- 991 __
- $a 20160913112408 $b ABA008
- 999 __
- $a ind $b bmc $g 1154630 $s 944488
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 3 $c - $d 9-16 $e 20150311 $i 2214-7535 $m Biomolecular detection and quantification $n Biomol Detect Quantif $x MED00189513
- LZP __
- $a Pubmed-20160722