Determination of alkylphenols in water samples using liquid chromatography-tandem mass spectrometry after pre-column derivatization with dansyl chloride
M. Pernica, P. Poloucká, M. Seifertová, Z. Šimek,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Benzhydryl Compounds analysis MeSH
- Water Pollutants, Chemical analysis MeSH
- Chromatography, Liquid methods MeSH
- Phenols analysis MeSH
- Indicators and Reagents MeSH
- Limit of Detection MeSH
- Drinking Water analysis MeSH
- Dansyl Compounds chemistry MeSH
- Tandem Mass Spectrometry methods MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The present study describes an effect of reaction condition of pre-column derivatization of alkylphenols (APs): bisphenol A (BPA), 4-tert-octylphenol (4-t-OP), 4-octylphenol (4-OP), 4-n-nonylphenol (4-n-NP), and isomers of 4-nonylphenol (iso-NP) with 5-(dimethylamino) naphthalene-1-sulfonyl chloride (dansyl chloride, DNSC) on their LC-ESI-MS/MS determination in water samples. Chemical derivatization improves the sensitivity and selectivity of LC-MS/MS analysis. In principle, alkylphenols can be analyzed by LC-MS/MS without derivatization. However, pre-column derivatization of APs increases the sensitivity up to 1000 times in comparison with the analysis of underivatized alkylphenols. Reaction conditions affecting formation of the DNSC-derivatives, such as various solvent, reaction temperature, reaction time, DNSC concentration and pH values were tested. The most suitable conditions, in terms of achieving a high sensitivity, resulting from this study are: acetonitrile as reaction solvent, 60 min as reaction time, 60 °C as reaction temperature, pH values 10.5, 0.5 mg mL(-1) as DNSC concentration. Calibration curves are linear at least in the range of 1-1000 ng mL(-1), limits of detection (LOD) and limits of quantification (LOQ) ranging from 0.02 to 0.25 pg/injection and from 0.08 to 0.83 pg/injection, respectively. The improved procedure was successfully applied for the analysis of APs and BPA in real water samples. The median concentration of BPA and iso-NP obtained in bottled waters was 4.7 ng L(-1) and 33.5 ng L(-1), respectively. The median concentration of 4-t-OP was 1.3 ng L(-1.)
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16020282
- 003
- CZ-PrNML
- 005
- 20160801103305.0
- 007
- ta
- 008
- 160722s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2015.09.030 $2 doi
- 024 7_
- $a 10.1016/j.chroma.2015.09.030 $2 doi
- 035 __
- $a (PubMed)26381567
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Pernica, Marek $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment RECETOX, Kamenice 753/5, 625 00 Brno, Czech Republic.
- 245 10
- $a Determination of alkylphenols in water samples using liquid chromatography-tandem mass spectrometry after pre-column derivatization with dansyl chloride / $c M. Pernica, P. Poloucká, M. Seifertová, Z. Šimek,
- 520 9_
- $a The present study describes an effect of reaction condition of pre-column derivatization of alkylphenols (APs): bisphenol A (BPA), 4-tert-octylphenol (4-t-OP), 4-octylphenol (4-OP), 4-n-nonylphenol (4-n-NP), and isomers of 4-nonylphenol (iso-NP) with 5-(dimethylamino) naphthalene-1-sulfonyl chloride (dansyl chloride, DNSC) on their LC-ESI-MS/MS determination in water samples. Chemical derivatization improves the sensitivity and selectivity of LC-MS/MS analysis. In principle, alkylphenols can be analyzed by LC-MS/MS without derivatization. However, pre-column derivatization of APs increases the sensitivity up to 1000 times in comparison with the analysis of underivatized alkylphenols. Reaction conditions affecting formation of the DNSC-derivatives, such as various solvent, reaction temperature, reaction time, DNSC concentration and pH values were tested. The most suitable conditions, in terms of achieving a high sensitivity, resulting from this study are: acetonitrile as reaction solvent, 60 min as reaction time, 60 °C as reaction temperature, pH values 10.5, 0.5 mg mL(-1) as DNSC concentration. Calibration curves are linear at least in the range of 1-1000 ng mL(-1), limits of detection (LOD) and limits of quantification (LOQ) ranging from 0.02 to 0.25 pg/injection and from 0.08 to 0.83 pg/injection, respectively. The improved procedure was successfully applied for the analysis of APs and BPA in real water samples. The median concentration of BPA and iso-NP obtained in bottled waters was 4.7 ng L(-1) and 33.5 ng L(-1), respectively. The median concentration of 4-t-OP was 1.3 ng L(-1.)
- 650 _2
- $a benzhydrylové sloučeniny $x analýza $7 D001559
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a sloučeniny dansylu $x chemie $7 D003619
- 650 _2
- $a pitná voda $x analýza $7 D060766
- 650 _2
- $a indikátory a reagencie $7 D007202
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a fenoly $x analýza $7 D010636
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Poloucká, Petra $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment RECETOX, Kamenice 753/5, 625 00 Brno, Czech Republic.
- 700 1_
- $a Seifertová, Marta $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment RECETOX, Kamenice 753/5, 625 00 Brno, Czech Republic.
- 700 1_
- $a Šimek, Zdeněk $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment RECETOX, Kamenice 753/5, 625 00 Brno, Czech Republic. Electronic address: simek@recetox.muni.cz.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A. Including electrophoresis and other separation methods $x 1873-3778 $g Roč. 1417, č. - (2015), s. 49-56
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26381567 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160722 $b ABA008
- 991 __
- $a 20160801103532 $b ABA008
- 999 __
- $a ok $b bmc $g 1154952 $s 944810
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 1417 $c - $d 49-56 $e 20150911 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962 $o Including electrophoresis and other separation methods
- LZP __
- $a Pubmed-20160722