• Je něco špatně v tomto záznamu ?

Prediction of wastewater quality using amperometric bioelectronic tongues

I. Czolkos, E. Dock, E. Tønning, J. Christensen, M. Winther-Nielsen, C. Carlsson, R. Mojzíková, P. Skládal, U. Wollenberger, L. Nørgaard, T. Ruzgas, J. Emnéus,

. 2016 ; 75 (-) : 375-82.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020319

Wastewater samples from a Swedish chemi-thermo-mechanical pulp (CTMP) mill collected at different purification stages in a wastewater treatment plant (WWTP) were analyzed with an amperometric enzyme-based biosensor array in a flow-injection system. In order to resolve the complex composition of the wastewater, the array consists of several sensing elements which yield a multidimensional response. We used principal component analysis (PCA) to decompose the array's responses, and found that wastewater with different degrees of pollution can be differentiated. With the help of partial least squares regression (PLS-R), we could link the sensor responses to the Microtox® toxicity parameter, as well as to global organic pollution parameters (COD, BOD, and TOC). From investigating the influences of individual sensors in the array, it was found that the best models were in most cases obtained when all sensors in the array were included in the PLS-R model. We find that fast simultaneous determination of several global environmental parameters characterizing wastewaters is possible with this kind of biosensor array, in particular because of the link between the sensor responses and the biological effect onto the ecosystem into which the wastewater would be released. In conjunction with multivariate data analysis tools, there is strong potential to reduce the total time until a result is yielded from days to a few minutes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020319
003      
CZ-PrNML
005      
20160726092833.0
007      
ta
008      
160722s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.bios.2015.08.055 $2 doi
024    7_
$a 10.1016/j.bios.2015.08.055 $2 doi
035    __
$a (PubMed)26342573
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Czolkos, Ilja $u DTU Nanotech - Department of Micro and Nanotechnology, Technical University of Denmark, Ørsteds Plads, 2800 Kgs. Lyngby, Denmark. Electronic address: ilcz@nanotech.dtu.dk.
245    10
$a Prediction of wastewater quality using amperometric bioelectronic tongues / $c I. Czolkos, E. Dock, E. Tønning, J. Christensen, M. Winther-Nielsen, C. Carlsson, R. Mojzíková, P. Skládal, U. Wollenberger, L. Nørgaard, T. Ruzgas, J. Emnéus,
520    9_
$a Wastewater samples from a Swedish chemi-thermo-mechanical pulp (CTMP) mill collected at different purification stages in a wastewater treatment plant (WWTP) were analyzed with an amperometric enzyme-based biosensor array in a flow-injection system. In order to resolve the complex composition of the wastewater, the array consists of several sensing elements which yield a multidimensional response. We used principal component analysis (PCA) to decompose the array's responses, and found that wastewater with different degrees of pollution can be differentiated. With the help of partial least squares regression (PLS-R), we could link the sensor responses to the Microtox® toxicity parameter, as well as to global organic pollution parameters (COD, BOD, and TOC). From investigating the influences of individual sensors in the array, it was found that the best models were in most cases obtained when all sensors in the array were included in the PLS-R model. We find that fast simultaneous determination of several global environmental parameters characterizing wastewaters is possible with this kind of biosensor array, in particular because of the link between the sensor responses and the biological effect onto the ecosystem into which the wastewater would be released. In conjunction with multivariate data analysis tools, there is strong potential to reduce the total time until a result is yielded from days to a few minutes.
650    12
$a biosenzitivní techniky $7 D015374
650    12
$a monitorování životního prostředí $7 D004784
650    _2
$a odpadní voda $x chemie $7 D062065
650    _2
$a chemické látky znečišťující vodu $x chemie $x izolace a purifikace $7 D014874
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Dock, Eva $u AkzoNobel Industrial Coatings AB, Staffanstorpsvägen 50, 205 17 Malmö, Sweden.
700    1_
$a Tønning, Erik $u Fiberline Composites A/S, Barmstedt Allé 5, 5500 Middelfart, Denmark.
700    1_
$a Christensen, Jakob $u Umetrics AB, Stortorget 21, 211 34 Malmö, Sweden.
700    1_
$a Winther-Nielsen, Margrethe $u Department of Environmental Risk Assessment, DHI Water and Environment, Agern Allé 5, 2970 Hørsholm, Denmark.
700    1_
$a Carlsson, Charlotte $u AnoxKaldnes AB, Klosterängsvägen 11A, 226 47 Lund, Sweden.
700    1_
$a Mojzíková, Renata $u Department of Biology, Faculty of Dentistry and Medicine, Palacký University Olumouc, Hněvotínská 3, 775 15 Olomouc, Czech Republic.
700    1_
$a Skládal, Petr $u Institute of Biochemistry, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic.
700    1_
$a Wollenberger, Ulla $u Analytical Biochemistry, Institute of Biochemistry and Biology, University of Potsdam, 14476 Golm, Germany.
700    1_
$a Nørgaard, Lars $u Department of Food Science, Faculty of Science, University of Copenhagen, Rolighedsvej 30, 1958 Frederiksberg, Denmark.
700    1_
$a Ruzgas, Tautgirdas $u Department of Biomedical Science, Faculty of Health and Society, Malmö University, Jan Waldenströms gata 25, 205 06 Malmö, Sweden.
700    1_
$a Emnéus, Jenny $u DTU Nanotech - Department of Micro and Nanotechnology, Technical University of Denmark, Ørsteds Plads, 2800 Kgs. Lyngby, Denmark. Electronic address: ilcz@nanotech.dtu.dk.
773    0_
$w MED00006627 $t Biosensors & bioelectronics $x 1873-4235 $g Roč. 75, č. - (2016), s. 375-82
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26342573 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160726093053 $b ABA008
999    __
$a ok $b bmc $g 1154989 $s 944847
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 75 $c - $d 375-82 $i 1873-4235 $m Biosensors & bioelectronics $n Biosens Bioelectron $x MED00006627
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...