• Je něco špatně v tomto záznamu ?

Corrosion behavior of Ti-39Nb alloy for dentistry

J. Fojt, L. Joska, J. Malek, V. Sefl,

. 2015 ; 56 (-) : 532-7. (Materials for biological applications) [pub] 20150719

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020431

To increase an orthopedic implant's lifetime, researchers are now concerned on the development of new titanium alloys with suitable mechanical properties (low elastic modulus-high fatigue strength), corrosion resistance and good workability. Corrosion resistance of the newly developed titanium alloys should be comparable with that of pure titanium. The effect of medical preparations containing fluoride ions represents a specific problem related to the use of titanium based materials in dentistry. The aim of this study was to determine the corrosion behavior of β titanium alloy Ti-39Nb in physiological saline solution and in physiological solution containing fluoride ions. Corrosion behavior was studied using standard electrochemical techniques and X-ray photoelectron spectroscopy. It was found that corrosion properties of the studied alloy were comparable with the properties of titanium grade 2. The passive layer was based on the oxides of titanium and niobium in several oxidation states. Alloying with niobium, which was the important part of the alloy passive layer, resulted in no significant changes of corrosion behavior. In the presence of fluoride ions, the corrosion resistance was higher than the resistance of titanium.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020431
003      
CZ-PrNML
005      
20160801112713.0
007      
ta
008      
160722s2015 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.msec.2015.07.029 $2 doi
024    7_
$a 10.1016/j.msec.2015.07.029 $2 doi
035    __
$a (PubMed)26249624
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Fojt, Jaroslav $u Institute of Chemical Technology, Technicka 5, 166 28 Prague, Czech Republic. Electronic address: fojtj@vscht.cz.
245    10
$a Corrosion behavior of Ti-39Nb alloy for dentistry / $c J. Fojt, L. Joska, J. Malek, V. Sefl,
520    9_
$a To increase an orthopedic implant's lifetime, researchers are now concerned on the development of new titanium alloys with suitable mechanical properties (low elastic modulus-high fatigue strength), corrosion resistance and good workability. Corrosion resistance of the newly developed titanium alloys should be comparable with that of pure titanium. The effect of medical preparations containing fluoride ions represents a specific problem related to the use of titanium based materials in dentistry. The aim of this study was to determine the corrosion behavior of β titanium alloy Ti-39Nb in physiological saline solution and in physiological solution containing fluoride ions. Corrosion behavior was studied using standard electrochemical techniques and X-ray photoelectron spectroscopy. It was found that corrosion properties of the studied alloy were comparable with the properties of titanium grade 2. The passive layer was based on the oxides of titanium and niobium in several oxidation states. Alloying with niobium, which was the important part of the alloy passive layer, resulted in no significant changes of corrosion behavior. In the presence of fluoride ions, the corrosion resistance was higher than the resistance of titanium.
650    _2
$a slitiny $x chemie $7 D000497
650    _2
$a koroze $7 D003343
650    12
$a zubní implantáty $7 D015921
650    _2
$a zubní lékařství $7 D003813
650    12
$a testování materiálů $7 D008422
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Joska, Ludek $u Institute of Chemical Technology, Technicka 5, 166 28 Prague, Czech Republic.
700    1_
$a Malek, Jaroslav $u UJP Praha, Nad Kamínkou 1345, 156 10 Prague-Zbraslav, Czech Republic.
700    1_
$a Sefl, Vaclav $u Institute of Chemical Technology, Technicka 5, 166 28 Prague, Czech Republic.
773    0_
$w MED00184559 $t Materials science & engineering. C, Materials for biological applications. Materials for biological applications $x 1873-0191 $g Roč. 56, č. - (2015), s. 532-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26249624 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160801112940 $b ABA008
999    __
$a ok $b bmc $g 1155101 $s 944959
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 56 $c - $d 532-7 $e 20150719 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559 $o Materials for biological applications
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...