-
Something wrong with this record ?
Validity and reliability of the Turkish version of the Visual Analog Sleep Scale
Funda Çetinkaya, Nezihe Karabulut
Language English Country Czech Republic
NLK
Directory of Open Access Journals
from 2014
ProQuest Central
from 2005-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2005
- MeSH
- Humans MeSH
- Sleep Wake Disorders * classification MeSH
- Reproducibility of Results * MeSH
- Statistics as Topic MeSH
- Visual Analog Scale * MeSH
- Check Tag
- Humans MeSH
- Geographicals
- Turkey MeSH
Objectives: The aim of this study was to adapt the English version of the Visual Analog Sleep Scale (VAS Scale) to Turkish, and to assess the validity and reliability of this Turkish version. Material and methods: The study design was both descriptive and methodological. The study group was comprised of 75 patients, who agreed to participate in the study. Each had received total hip replacement surgery in an orthopedic clinical hospital. Data was collected using a Turkish translation of the VAS Scale. Psychometric testing of the adapted instrument was carried out to establish internal consistency, interim correlation, and construct validity. The Kaiser-Meyer-Olkin and Barlett’s tests were applied to determine the sampling adequacy and suitability to the factor analysis. Results: The Kaiser-Meyer-Olkin value was found to be 0.89, and this value indicates suitability for principal component analysis. Similarly, Barlett’s test results (X2 = 608.74, p = 0.000) also indicate the interrelationships of the data and suitability for the factor analysis. The eigenvalue of the VAS Scale reduced to 10 items was found to be 6.65 and the variance was 66.52. The VAS Scale Cronbach’s alpha was 0.82 for the test items. The test-retest stability coefficient (validity of the scale) was 0.92. Alpha coefficient was found to be 0.94 for internal consistency. Conclusion: The original VAS Scale consisted of three sub-scales and 15 items, whereas the Turkish version has one dimension and 10 items. The Turkish version of the VAS Scale adapted to the orthopedics clinic can be used as a one-factor tool.
Aksaray University Health High School Department of Surgical Nursing Aksaray Turkey
Atatürk University The Faculty oh Health Science Department of Surgical Nursing Erzurum Turkey
References provided by Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16026252
- 003
- CZ-PrNML
- 005
- 20161209170839.0
- 007
- ta
- 008
- 160921s2016 xr f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.kontakt.2016.05.003 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Çetinkaya, Funda $u Aksaray University, Health High School, Department of Surgical Nursing, Aksaray, Turkey
- 245 10
- $a Validity and reliability of the Turkish version of the Visual Analog Sleep Scale / $c Funda Çetinkaya, Nezihe Karabulut
- 504 __
- $a Literatura
- 520 3_
- $a Objectives: The aim of this study was to adapt the English version of the Visual Analog Sleep Scale (VAS Scale) to Turkish, and to assess the validity and reliability of this Turkish version. Material and methods: The study design was both descriptive and methodological. The study group was comprised of 75 patients, who agreed to participate in the study. Each had received total hip replacement surgery in an orthopedic clinical hospital. Data was collected using a Turkish translation of the VAS Scale. Psychometric testing of the adapted instrument was carried out to establish internal consistency, interim correlation, and construct validity. The Kaiser-Meyer-Olkin and Barlett’s tests were applied to determine the sampling adequacy and suitability to the factor analysis. Results: The Kaiser-Meyer-Olkin value was found to be 0.89, and this value indicates suitability for principal component analysis. Similarly, Barlett’s test results (X2 = 608.74, p = 0.000) also indicate the interrelationships of the data and suitability for the factor analysis. The eigenvalue of the VAS Scale reduced to 10 items was found to be 6.65 and the variance was 66.52. The VAS Scale Cronbach’s alpha was 0.82 for the test items. The test-retest stability coefficient (validity of the scale) was 0.92. Alpha coefficient was found to be 0.94 for internal consistency. Conclusion: The original VAS Scale consisted of three sub-scales and 15 items, whereas the Turkish version has one dimension and 10 items. The Turkish version of the VAS Scale adapted to the orthopedics clinic can be used as a one-factor tool.
- 650 12
- $a poruchy spánku a bdění $x klasifikace $7 D012893
- 650 12
- $a vizuální analogová stupnice $7 D064232
- 650 12
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a statistika jako téma $7 D013223
- 650 _2
- $a lidé $7 D006801
- 651 _2
- $a Turecko $7 D014421
- 700 1_
- $a Karabulut, Nezihe $u Atatürk University, The Faculty oh Health Science, Department of Surgical Nursing, Erzurum, Turkey
- 773 0_
- $t Kontakt $x 1212-4117 $g Roč. 18, č. 2 (2016), s. 94-99 $w MED00011467
- 856 41
- $u https://kont.zsf.jcu.cz/pdfs/knt/2016/02/06.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 2178 $c 1249 a $y 4 $z 0
- 990 __
- $a 20160921133704 $b ABA008
- 991 __
- $a 20161209170847 $b ABA008
- 999 __
- $a ok $b bmc $g 1163745 $s 950861
- BAS __
- $a 3
- BMC __
- $a 2016 $b 18 $c 2 $d 94-99 $i 1212-4117 $m Kontakt (České Budějovice) $n Kontakt (Čes. Budějovice Print) $x MED00011467
- LZP __
- $c NLK121 $d 20161209 $a NLK 2016-34/pk