Je něco špatně v tomto záznamu ?
Method for analysis of psychopharmaceuticals in real industrial wastewater and groundwater with suspended organic particulate matter using solid phase extraction disks extraction and ultra-high performance liquid chromatography/time-of-flight mass spectrometry
Z. Křesinová, L. Linhartová, K. Petrů, L. Krejčová, K. Šrédlová, O. Lhotský, Z. Kameník, T. Cajthaml,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- extrakce na pevné fázi * MeSH
- hmotnostní spektrometrie * MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- odpadní voda chemie MeSH
- pevné částice analýza MeSH
- podzemní voda chemie MeSH
- psychotropní léky analýza MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
A rapid and reliable analytical method was developed for the quantitative determination of psychopharmaceuticals, their precursors and by-products in real contaminated samples from a pharmaceutical company in Olomouc (Czech Republic), based on SPE disk extraction and detection by ultra performance liquid chromatography, combined with time-of-flight mass spectrometry. The target compounds were quantified in the real whole-water samples (water including suspended particles), both in the presence of suspended particulate matter (SPM) and high concentrations of other organic pollutants. A total of nine compounds were analyzed which consisted of three commonly used antidepressants (tricyclic antidepressants and antipsychotics), one antitussive agent and five by-products or precursors. At first, the SPE disk method was developed for the extraction of water samples (dissolved analytes, recovery 84-104%) and pressurised liquid extraction technique was verified for solid matrices (sludge samples, recovery 81-95%). In order to evaluate the SPE disk technique for whole water samples containing SPM, non contaminated groundwater samples were also loaded with different amounts (100 and 300mgL(-1)) of real contaminated sludge originating from the same locality. The recoveries from the whole-water samples obtained by SPE disk method ranged between 67 and 119% after the addition of the most contaminated sludge. The final method was applied to several real groundwater (whole-water) samples from the industrial area and high concentrations (up to 10(3)μgL(-1)) of the target compounds were detected. The results of this study document and indicate the feasibility of the SPE disk method for analysis of groundwater.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16027623
- 003
- CZ-PrNML
- 005
- 20161025103231.0
- 007
- ta
- 008
- 161005s2016 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2016.02.035 $2 doi
- 024 7_
- $a 10.1016/j.chroma.2016.02.035 $2 doi
- 035 __
- $a (PubMed)26924752
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Křesinová, Zdena $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic; Institute for Environmental Studies, Faculty of Science, Charles University of Prague, Benátská 2, CZ-128 01, Prague 2, Czech Republic.
- 245 10
- $a Method for analysis of psychopharmaceuticals in real industrial wastewater and groundwater with suspended organic particulate matter using solid phase extraction disks extraction and ultra-high performance liquid chromatography/time-of-flight mass spectrometry / $c Z. Křesinová, L. Linhartová, K. Petrů, L. Krejčová, K. Šrédlová, O. Lhotský, Z. Kameník, T. Cajthaml,
- 520 9_
- $a A rapid and reliable analytical method was developed for the quantitative determination of psychopharmaceuticals, their precursors and by-products in real contaminated samples from a pharmaceutical company in Olomouc (Czech Republic), based on SPE disk extraction and detection by ultra performance liquid chromatography, combined with time-of-flight mass spectrometry. The target compounds were quantified in the real whole-water samples (water including suspended particles), both in the presence of suspended particulate matter (SPM) and high concentrations of other organic pollutants. A total of nine compounds were analyzed which consisted of three commonly used antidepressants (tricyclic antidepressants and antipsychotics), one antitussive agent and five by-products or precursors. At first, the SPE disk method was developed for the extraction of water samples (dissolved analytes, recovery 84-104%) and pressurised liquid extraction technique was verified for solid matrices (sludge samples, recovery 81-95%). In order to evaluate the SPE disk technique for whole water samples containing SPM, non contaminated groundwater samples were also loaded with different amounts (100 and 300mgL(-1)) of real contaminated sludge originating from the same locality. The recoveries from the whole-water samples obtained by SPE disk method ranged between 67 and 119% after the addition of the most contaminated sludge. The final method was applied to several real groundwater (whole-water) samples from the industrial area and high concentrations (up to 10(3)μgL(-1)) of the target compounds were detected. The results of this study document and indicate the feasibility of the SPE disk method for analysis of groundwater.
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 _2
- $a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
- 650 _2
- $a podzemní voda $x chemie $7 D060587
- 650 12
- $a hmotnostní spektrometrie $7 D013058
- 650 _2
- $a pevné částice $x analýza $7 D052638
- 650 _2
- $a psychotropní léky $x analýza $7 D011619
- 650 12
- $a extrakce na pevné fázi $7 D052616
- 650 _2
- $a odpadní voda $x chemie $7 D062065
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Linhartová, Lucie $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic.
- 700 1_
- $a Petrů, Klára $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic.
- 700 1_
- $a Krejčová, Lucie $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic; Institute for Environmental Studies, Faculty of Science, Charles University of Prague, Benátská 2, CZ-128 01, Prague 2, Czech Republic.
- 700 1_
- $a Šrédlová, Kamila $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic; Institute for Environmental Studies, Faculty of Science, Charles University of Prague, Benátská 2, CZ-128 01, Prague 2, Czech Republic.
- 700 1_
- $a Lhotský, Ondřej $u Institute for Environmental Studies, Faculty of Science, Charles University of Prague, Benátská 2, CZ-128 01, Prague 2, Czech Republic; DEKONTA a.s., Volutová 2523, CZ-158 00, Prague 5, Czech Republic.
- 700 1_
- $a Kameník, Zdeněk $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic.
- 700 1_
- $a Cajthaml, Tomáš $u Institute of Microbiology Academy of Sciences of the Czech Republic, v.v.i., Vídeňská 1083, CZ-142 20, Prague 4, Czech Republic; Institute for Environmental Studies, Faculty of Science, Charles University of Prague, Benátská 2, CZ-128 01, Prague 2, Czech Republic. Electronic address: cajthaml@biomed.cas.cz.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1440, č. - (2016), s. 15-22
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26924752 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20161025103644 $b ABA008
- 999 __
- $a ok $b bmc $g 1165937 $s 952253
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 1440 $c - $d 15-22 $e 20160212 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20161005