Something wrong with this record ?
Additional considerations on electrolysis in electromembrane extraction
A. Šlampová, P. Kubáň, P. Boček,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Electrophoresis, Capillary MeSH
- Electrolysis * MeSH
- Liquid-Liquid Extraction * MeSH
- Ions chemistry MeSH
- Membranes, Artificial * MeSH
- Nitrobenzenes chemistry MeSH
- Solutions chemistry MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Optimized acceptor solutions, which eliminate electrolytically induced variations in their pH values, have been shown to improve electromembrane extraction (EME) performance. Acceptor solutions containing 500 mM formic acid (pH 1.97) ensured stable EME process for three basic drugs extracted at 50 V across 1-ethyl-2-nitrobenzene and constant extraction recoveries (66-89%) were achieved for 40-80 min EMEs. Back-extraction of analytes into donor solutions has been eliminated by application of optimized acceptor solutions, moreover, saturation of acceptor solutions with analytes had no additional effect on their back-extraction; the presence of up to 300-fold excess of analytes in optimized acceptor solutions led to slightly reduced but stable enrichment of analytes over the entire extraction time. Stable EME performance has been also achieved for extractions into 100mM HCl, note however, that seriously compromised performance of subsequent capillary electrophoretic analyses has been observed due to high conductivities of resulting acceptor solutions. Electrolytically produced H(+) and OH(-) ions have mostly remained in corresponding operating solutions, have determined their final pH values and have not been subjects of EME transfers across selective phase interfaces as was experimentally verified by pH measurements of anolytes and catholytes at various EME times.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16027777
- 003
- CZ-PrNML
- 005
- 20161025103408.0
- 007
- ta
- 008
- 161005s2016 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2015.12.028 $2 doi
- 024 7_
- $a 10.1016/j.chroma.2015.12.028 $2 doi
- 035 __
- $a (PubMed)26709026
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Šlampová, Andrea $u Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic.
- 245 10
- $a Additional considerations on electrolysis in electromembrane extraction / $c A. Šlampová, P. Kubáň, P. Boček,
- 520 9_
- $a Optimized acceptor solutions, which eliminate electrolytically induced variations in their pH values, have been shown to improve electromembrane extraction (EME) performance. Acceptor solutions containing 500 mM formic acid (pH 1.97) ensured stable EME process for three basic drugs extracted at 50 V across 1-ethyl-2-nitrobenzene and constant extraction recoveries (66-89%) were achieved for 40-80 min EMEs. Back-extraction of analytes into donor solutions has been eliminated by application of optimized acceptor solutions, moreover, saturation of acceptor solutions with analytes had no additional effect on their back-extraction; the presence of up to 300-fold excess of analytes in optimized acceptor solutions led to slightly reduced but stable enrichment of analytes over the entire extraction time. Stable EME performance has been also achieved for extractions into 100mM HCl, note however, that seriously compromised performance of subsequent capillary electrophoretic analyses has been observed due to high conductivities of resulting acceptor solutions. Electrolytically produced H(+) and OH(-) ions have mostly remained in corresponding operating solutions, have determined their final pH values and have not been subjects of EME transfers across selective phase interfaces as was experimentally verified by pH measurements of anolytes and catholytes at various EME times.
- 650 12
- $a elektrolýza $7 D004572
- 650 _2
- $a elektroforéza kapilární $7 D019075
- 650 _2
- $a ionty $x chemie $7 D007477
- 650 12
- $a extrakce kapalina-kapalina $7 D059625
- 650 12
- $a membrány umělé $7 D008567
- 650 _2
- $a nitrobenzeny $x chemie $7 D009578
- 650 _2
- $a roztoky $x chemie $7 D012996
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic. Electronic address: kuban@iach.cz.
- 700 1_
- $a Boček, Petr $u Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1429, č. - (2016), s. 364-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26709026 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20161025103821 $b ABA008
- 999 __
- $a ok $b bmc $g 1166091 $s 952407
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 1429 $c - $d 364-8 $e 20151211 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20161005