Effects of fatty acyl chain length, double-bond number and matrix on phosphatidylcholine responses in matrix-assisted laser desorption/ionization on an Orbitrap mass spectrometer

V. Chagovets, M. Lísa, M. Holčapek,

. 2015 ; 29 (24) : 2374-84.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16027964

RATIONALE: Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is used for the fast qualitative and quantitative analysis of phosphatidylcholines (PC). Fatty acyl chain lengths and the number of double bonds (DB) affect relative responses of PC; hence the determination of correction factors of individual PC is important for the accurate quantitation. The signal intensity in MALDI-MS strongly depends on the matrix; therefore, the following matrices typically used in lipidomics are studied in the present work: 2,5-dihydroxybenzoic acid (DHB), 1,5-diaminonaphthalene (DAN) and 9-aminoacridine (9AA). METHODS: Series of PC with various fatty acyl chain lengths are synthesized for this study. PC concentrations over two orders of magnitude are studied with MALDI-MS. These experiments provide sets of calibration curves for each of the synthesized PC and the further analysis of parameters of calibration curves is performed. RESULTS: Correction factors for PC decrease with increasing fatty acyl chain length for all matrices. These dependences are steeper for unsaturated PC than for saturated ones. MALDI matrices also have a significant effect on this dependence. The weakest dependence on fatty acyl chain length is found for saturated PC in 9AA. In the case of the other matrices, the effect of fatty acyl chain length on the response is essential for both saturated and unsaturated PC. Calibration curves and parameters of calibration curves for both saturated and monounsaturated PC are fitted by a linear function with regression coefficients decreasing in the order 9AA > DAN > DHB. CONCLUSIONS: Differences in relative responses for PC in MALDI-MS measurements must be taken into account for accurate quantitation. Parameters of calibration curves can be used for the determination of PC concentrations using a single internal standard (IS). This method gives good results for the 9AA matrix, but the reproducibility of measurements for the DHB and DAN matrices is lower and the method can be used for a rough estimation only. These matrices are less convenient for the quantitation of PC.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16027964
003      
CZ-PrNML
005      
20161031114248.0
007      
ta
008      
161005s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/rcm.7404 $2 doi
024    7_
$a 10.1002/rcm.7404 $2 doi
035    __
$a (PubMed)26563708
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Chagovets, Vitaliy $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
245    10
$a Effects of fatty acyl chain length, double-bond number and matrix on phosphatidylcholine responses in matrix-assisted laser desorption/ionization on an Orbitrap mass spectrometer / $c V. Chagovets, M. Lísa, M. Holčapek,
520    9_
$a RATIONALE: Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is used for the fast qualitative and quantitative analysis of phosphatidylcholines (PC). Fatty acyl chain lengths and the number of double bonds (DB) affect relative responses of PC; hence the determination of correction factors of individual PC is important for the accurate quantitation. The signal intensity in MALDI-MS strongly depends on the matrix; therefore, the following matrices typically used in lipidomics are studied in the present work: 2,5-dihydroxybenzoic acid (DHB), 1,5-diaminonaphthalene (DAN) and 9-aminoacridine (9AA). METHODS: Series of PC with various fatty acyl chain lengths are synthesized for this study. PC concentrations over two orders of magnitude are studied with MALDI-MS. These experiments provide sets of calibration curves for each of the synthesized PC and the further analysis of parameters of calibration curves is performed. RESULTS: Correction factors for PC decrease with increasing fatty acyl chain length for all matrices. These dependences are steeper for unsaturated PC than for saturated ones. MALDI matrices also have a significant effect on this dependence. The weakest dependence on fatty acyl chain length is found for saturated PC in 9AA. In the case of the other matrices, the effect of fatty acyl chain length on the response is essential for both saturated and unsaturated PC. Calibration curves and parameters of calibration curves for both saturated and monounsaturated PC are fitted by a linear function with regression coefficients decreasing in the order 9AA > DAN > DHB. CONCLUSIONS: Differences in relative responses for PC in MALDI-MS measurements must be taken into account for accurate quantitation. Parameters of calibration curves can be used for the determination of PC concentrations using a single internal standard (IS). This method gives good results for the 9AA matrix, but the reproducibility of measurements for the DHB and DAN matrices is lower and the method can be used for a rough estimation only. These matrices are less convenient for the quantitation of PC.
650    _2
$a lidé $7 D006801
650    _2
$a fosfatidylcholiny $x krev $x chemie $7 D010713
650    _2
$a spektrometrie hmotnostní - ionizace laserem za účasti matrice $x metody $7 D019032
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Lísa, Miroslav $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
700    1_
$a Holčapek, Michal $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
773    0_
$w MED00004050 $t Rapid communications in mass spectrometry RCM $x 1097-0231 $g Roč. 29, č. 24 (2015), s. 2374-84
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26563708 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20161005 $b ABA008
991    __
$a 20161031114212 $b ABA008
999    __
$a ok $b bmc $g 1166278 $s 952594
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 29 $c 24 $d 2374-84 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a Pubmed-20161005

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...