-
Je něco špatně v tomto záznamu ?
Integrated, DC voltage-driven nucleic acid diagnostic platform for real sample analysis: Detection of oral cancer
Z. Slouka, S. Senapati, S. Shah, R. Lawler, Z. Shi, MS. Stack, HC. Chang,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, Research Support, N.I.H., Extramural, práce podpořená grantem, Research Support, U.S. Gov't, Non-P.H.S.
- MeSH
- elektrická vodivost * MeSH
- laboratoř na čipu * ekonomika MeSH
- mikro RNA analýza MeSH
- nádorové biomarkery analýza MeSH
- nádory úst diagnóza MeSH
- systémová integrace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
- Research Support, U.S. Gov't, Non-P.H.S. MeSH
We present an integrated and low-cost microfluidic platform capable of extraction of nucleic acids from real biological samples. We demonstrate the application of this platform in pathogen detection and cancer screening. The integrated platform consists of three units including a pretreatment unit for separation of nucleic acids from lysates, a preconcentration unit for concentration of isolated nucleic acids and a sensing unit localized at a designated position on the chip for specific detection of the target nucleic acid. The platform is based on various electrokinetic phenomena exhibited by ion exchange membranes in a DC electrical field that allow them to serve as molecular filters, analyte preconcentrators and sensors. In this manuscript, we describe each unit of the integrated chip separately and show specific detection of a microRNA (miRNA 146a) biomarker associated with oral cancer as a proof-of-concept experiment. This platform technology can easily be extended to other targets of interest by optimizing the properties of the ion exchange membranes and the specific probes functionalized onto the sensors.
Department of Chemical and Biomolecular Engineering University of Notre Dame Notre Dame IN 46556 USA
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16028107
- 003
- CZ-PrNML
- 005
- 20161031105658.0
- 007
- ta
- 008
- 161005s2015 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2015.04.083 $2 doi
- 024 7_
- $a 10.1016/j.talanta.2015.04.083 $2 doi
- 035 __
- $a (PubMed)26459441
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Slouka, Zdenek $u Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, USA; Department of Chemical Engineering, University of Chemistry and Technology, Technicka 3, Prague 6 16628, Czech Republic.
- 245 10
- $a Integrated, DC voltage-driven nucleic acid diagnostic platform for real sample analysis: Detection of oral cancer / $c Z. Slouka, S. Senapati, S. Shah, R. Lawler, Z. Shi, MS. Stack, HC. Chang,
- 520 9_
- $a We present an integrated and low-cost microfluidic platform capable of extraction of nucleic acids from real biological samples. We demonstrate the application of this platform in pathogen detection and cancer screening. The integrated platform consists of three units including a pretreatment unit for separation of nucleic acids from lysates, a preconcentration unit for concentration of isolated nucleic acids and a sensing unit localized at a designated position on the chip for specific detection of the target nucleic acid. The platform is based on various electrokinetic phenomena exhibited by ion exchange membranes in a DC electrical field that allow them to serve as molecular filters, analyte preconcentrators and sensors. In this manuscript, we describe each unit of the integrated chip separately and show specific detection of a microRNA (miRNA 146a) biomarker associated with oral cancer as a proof-of-concept experiment. This platform technology can easily be extended to other targets of interest by optimizing the properties of the ion exchange membranes and the specific probes functionalized onto the sensors.
- 650 _2
- $a nádorové biomarkery $x analýza $7 D014408
- 650 12
- $a elektrická vodivost $7 D004553
- 650 12
- $a laboratoř na čipu $x ekonomika $7 D056656
- 650 _2
- $a mikro RNA $x analýza $7 D035683
- 650 _2
- $a nádory úst $x diagnóza $7 D009062
- 650 _2
- $a systémová integrace $7 D018511
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a Research Support, N.I.H., Extramural $7 D052061
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a Research Support, U.S. Gov't, Non-P.H.S. $7 D013486
- 700 1_
- $a Senapati, Satyajyoti $u Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.
- 700 1_
- $a Shah, Sunny $u Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.
- 700 1_
- $a Lawler, Robin $u Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.
- 700 1_
- $a Shi, Zonggao $u Department of Chemistry and Biochemistry and Harper Cancer Research Institute, University of Notre Dame, Notre Dame, IN 46556, USA.
- 700 1_
- $a Stack, M Sharon $u Department of Chemistry and Biochemistry and Harper Cancer Research Institute, University of Notre Dame, Notre Dame, IN 46556, USA.
- 700 1_
- $a Chang, Hsueh-Chia $u Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN 46556, USA. Electronic address: hchang@nd.edu.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 145, č. - (2015), s. 35-42
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26459441 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20161031110120 $b ABA008
- 999 __
- $a ok $b bmc $g 1166421 $s 952737
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 145 $c - $d 35-42 $e 20150506 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20161005