Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

A new large-volume metal reference standard for radioactive waste management

F. Tzika, M. Hult, H. Stroh, G. Marissens, D. Arnold, O. Burda, P. Kovář, J. Suran, A. Listkowska, Z. Tyminski,

. 2016 ; 168 (3) : 293-9. [pub] 20150513

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc17001140

A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17001140
003      
CZ-PrNML
005      
20170119103120.0
007      
ta
008      
170103s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncv309 $2 doi
024    7_
$a 10.1093/rpd/ncv309 $2 doi
035    __
$a (PubMed)25977349
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Tzika, F $u EC-JRC-IRMM, European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, Geel 2440, Belgium Present address: EC-JRC-ITU, Institute for Transuranium Elements, PO Box 2340, Karlsruhe 76125, Germany faidra.tzika@ec.europa.eu.
245    12
$a A new large-volume metal reference standard for radioactive waste management / $c F. Tzika, M. Hult, H. Stroh, G. Marissens, D. Arnold, O. Burda, P. Kovář, J. Suran, A. Listkowska, Z. Tyminski,
520    9_
$a A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values.
650    _2
$a radioizotopy kobaltu $x analýza $7 D003037
650    _2
$a lidé $7 D006801
650    _2
$a monitorování radiace $x metody $7 D011834
650    _2
$a radioaktivní odpad $x analýza $7 D011850
650    _2
$a referenční standardy $7 D012015
650    _2
$a stříbro $x analýza $7 D012834
650    _2
$a nakládání s odpady $x normy $7 D018505
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Hult, M $u EC-JRC-IRMM, European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, Geel 2440, Belgium.
700    1_
$a Stroh, H $u EC-JRC-IRMM, European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, Geel 2440, Belgium.
700    1_
$a Marissens, G $u EC-JRC-IRMM, European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, Geel 2440, Belgium.
700    1_
$a Arnold, D $u PTB, Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig 38116, Germany. $7 gn_A_00008703
700    1_
$a Burda, O $u PTB, Physikalisch-Technische Bundesanstalt, Bundesallee 100, Braunschweig 38116, Germany.
700    1_
$a Kovář, P $u CMI, Czech Metrology Institute, Radiová 1a, Praha 10 102 00, Czech Republic.
700    1_
$a Suran, J $u CMI, Czech Metrology Institute, Radiová 1a, Praha 10 102 00, Czech Republic.
700    1_
$a Listkowska, A $u NCBJ, Narodowe Centrum Badań Jądrowych RC POLATOM, ul. Andrzeja Sołtana 7, Otwock-Świerk 05-400, Poland.
700    1_
$a Tyminski, Z $u NCBJ, Narodowe Centrum Badań Jądrowych RC POLATOM, ul. Andrzeja Sołtana 7, Otwock-Świerk 05-400, Poland.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 168, č. 3 (2016), s. 293-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25977349 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170103 $b ABA008
991    __
$a 20170119103229 $b ABA008
999    __
$a ok $b bmc $g 1180280 $s 961707
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 168 $c 3 $d 293-9 $e 20150513 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20170103

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...