-
Something wrong with this record ?
The influence of the anastomosis angle on the hemodynamics in the distal anastomosis in the infrainguinal bypass: an in vitro study
T. Grus, G. Grusová, L. Lambert, R. Banerjee, J. Matěcha, M. Mlček
Language English Country Czech Republic
Document type Comparative Study, Journal Article
Grant support
NV15-27941A
MZ0
CEP Register
Digital library NLK
Full text - Article
Source
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Anastomosis, Surgical methods MeSH
- Lower Extremity blood supply MeSH
- Hemodynamics MeSH
- Humans MeSH
- Hemorheology MeSH
- Vascular Surgical Procedures methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Comparative Study MeSH
The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25°, 45°, and 60° respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45° and 60° models. In the 25° model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.
2nd Department of Surgery 1st Faculty of Medicine Charles University Prague Prague
4th Department of Internal Medicine 1st Faculty of Medicine Charles University Prague Prague
Department of Physiology 1st Faculty of Medicine Charles University Prague Prague Czech Republic
Department of Radiology 1st Faculty of Medicine Charles University Prague Prague
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17012761
- 003
- CZ-PrNML
- 005
- 20201020112240.0
- 007
- ta
- 008
- 170412s2016 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933176 $2 doi
- 035 __
- $a (PubMed)26988154
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Grus, Tomáš, $u Second Department of Surgery, First Faculty of Medicine, Charles University in Prague, Prague $d 1974- $7 xx0080427
- 245 14
- $a The influence of the anastomosis angle on the hemodynamics in the distal anastomosis in the infrainguinal bypass: an in vitro study / $c T. Grus, G. Grusová, L. Lambert, R. Banerjee, J. Matěcha, M. Mlček
- 520 9_
- $a The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25°, 45°, and 60° respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45° and 60° models. In the 25° model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.
- 650 _2
- $a anastomóza chirurgická $x metody $7 D000714
- 650 _2
- $a hemodynamika $7 D006439
- 650 _2
- $a reologie krve $7 D018056
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a dolní končetina $x krevní zásobení $7 D035002
- 650 _2
- $a výkony cévní chirurgie $x metody $7 D014656
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Grusová, Gabriela $7 xx0121713 $u Fourth Department of Internal Medicine, First Faculty of Medicine, Charles University in Prague, Prague
- 700 1_
- $a Lambert, Lukáš $7 xx0145830 $u Department of Radiology, First Faculty of Medicine, Charles University in Prague, Prague
- 700 1_
- $a Banerjee, Rohan $7 xx0224832 $u Department of Radiology, First Faculty of Medicine, Charles University in Prague, Prague
- 700 1_
- $a Matěcha, Jan $7 ctu2013761406 $u Department of Fluid Dynamics and Power Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Department of Physiology, First Faculty of Medicine, Charles University in Prague, Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 65, č. 4 (2016), s. 591-595
- 856 41
- $u http://www.biomed.cas.cz/physiolres/ $y domovská stránka časopisu
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20170412 $b ABA008
- 991 __
- $a 20201020112236 $b ABA008
- 999 __
- $a ok $b bmc $g 1201696 $s 973534
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 65 $c 4 $d 591-595 $e 20160315 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- GRA __
- $a NV15-27941A $p MZ0
- LZP __
- $b NLK118 $a Pubmed-20170412