The ratio of diameters between the target artery and the bypass modifies hemodynamic parameters related to intimal hyperplasia in the distal end-to-side anastomosis
T. Grus, L. Lambert, J. Matěcha, G. Grusová, M. Špaček, M. Mlček
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
Grantová podpora
NV15-27941A
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- anastomóza chirurgická * MeSH
- arterie anatomie a histologie fyziologie chirurgie MeSH
- fyziologický stres MeSH
- hemodynamika * MeSH
- hyperplazie * MeSH
- mechanický stres MeSH
- modely kardiovaskulární MeSH
- pevnost ve smyku MeSH
- přenos energie MeSH
- pulzatilní průtok MeSH
- rychlost toku krve MeSH
- Publikační typ
- časopisecké články MeSH
Hemodynamics in the distal end-to-side anastomosis is related to early development of intimal hyperplasia and bypass failure. In this study we investigated the effect of diameter ratios between the target artery and the bypass at three different angles of the connection. The pulsatile flow field was visualized using particle image velocimetry in transparent models with three different angles of the connection (25°, 45°, 60°) and the diameter ratio between the bypass and the target artery was 4.6 mm : 6 mm, 6 mm : 6 mm, and 7.5 mm : 6 mm. Six parameters including location and oscillation of the stagnation point, local energy dissipation, wall shear stress (WSS), oscillatory shear index, spatial and temporal gradient of WSS and their distribution in the target artery were calculated from the flow field. In the wider bypass, the stagnation point oscillated in a greater range and was located more proximal to the anastomosis. Energy dissipation was minimal in a wider bypass with a more acute angle. The maximum WSS values were tree times greater in a narrow bypass and concentrated in a smaller circular region at the floor of the anastomosis. The oscillatory shear index increased with wider bypass and more acute angle. The maximum of spatial gradient of WSS concentrated around the floor and toe of the anastomosis and decreased with more acute angle and wider bypass, the temporal gradient of WSS was stretched more towards the side wall. Greater bypass to target vessel ratio and more acute anastomosis angle promote hemodynamics known to reduce formation of intimal hyperplasia.
4th Department of Internal Medicine 1st Faculty of Medicine Charles University Prague Czech Republic
Department of Physiology 1st Faculty of Medicine Charles University Prague Czech Republic
Department of Radiology 1st Faculty of Medicine Charles University in Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17012801
- 003
- CZ-PrNML
- 005
- 20201020112301.0
- 007
- ta
- 008
- 170412s2016 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933297 $2 doi
- 035 __
- $a (PubMed)27539100
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Grus, Tomáš, $u Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University in Prague, Czech Republic $d 1974- $7 xx0080427
- 245 14
- $a The ratio of diameters between the target artery and the bypass modifies hemodynamic parameters related to intimal hyperplasia in the distal end-to-side anastomosis / $c T. Grus, L. Lambert, J. Matěcha, G. Grusová, M. Špaček, M. Mlček
- 520 9_
- $a Hemodynamics in the distal end-to-side anastomosis is related to early development of intimal hyperplasia and bypass failure. In this study we investigated the effect of diameter ratios between the target artery and the bypass at three different angles of the connection. The pulsatile flow field was visualized using particle image velocimetry in transparent models with three different angles of the connection (25°, 45°, 60°) and the diameter ratio between the bypass and the target artery was 4.6 mm : 6 mm, 6 mm : 6 mm, and 7.5 mm : 6 mm. Six parameters including location and oscillation of the stagnation point, local energy dissipation, wall shear stress (WSS), oscillatory shear index, spatial and temporal gradient of WSS and their distribution in the target artery were calculated from the flow field. In the wider bypass, the stagnation point oscillated in a greater range and was located more proximal to the anastomosis. Energy dissipation was minimal in a wider bypass with a more acute angle. The maximum WSS values were tree times greater in a narrow bypass and concentrated in a smaller circular region at the floor of the anastomosis. The oscillatory shear index increased with wider bypass and more acute angle. The maximum of spatial gradient of WSS concentrated around the floor and toe of the anastomosis and decreased with more acute angle and wider bypass, the temporal gradient of WSS was stretched more towards the side wall. Greater bypass to target vessel ratio and more acute anastomosis angle promote hemodynamics known to reduce formation of intimal hyperplasia.
- 650 12
- $a anastomóza chirurgická $7 D000714
- 650 _2
- $a arterie $x anatomie a histologie $x fyziologie $x chirurgie $7 D001158
- 650 _2
- $a rychlost toku krve $7 D001783
- 650 _2
- $a přenos energie $7 D004735
- 650 12
- $a hemodynamika $7 D006439
- 650 12
- $a hyperplazie $7 D006965
- 650 _2
- $a modely kardiovaskulární $7 D008955
- 650 _2
- $a pulzatilní průtok $7 D011673
- 650 _2
- $a pevnost ve smyku $7 D033081
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a fyziologický stres $7 D013312
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Lambert, Lukáš $7 xx0145830 $u Department of Radiology, First Faculty of Medicine, Charles University in Prague, Czech Republic
- 700 1_
- $a Matěcha, Jan $7 ctu2013761406 $u Department of Fluid Dynamics and Power Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech Republi
- 700 1_
- $a Grusová, Gabriela $7 xx0121713 $u Fourth Department of Internal Medicine, First Faculty of Medicine, Charles University in Prague, Czech Republic
- 700 1_
- $a Špaček, Miloslav $7 xx0210942 $u Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University in Prague, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Department of Physiology, First Faculty of Medicine, Charles University in Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 65, č. 6 (2016), s. 901-908
- 856 41
- $u http://www.biomed.cas.cz/physiolres/ $y domovská stránka časopisu
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20170412 $b ABA008
- 991 __
- $a 20201020112257 $b ABA008
- 999 __
- $a ok $b bmc $g 1205358 $s 973574
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 65 $c 6 $d 901-908 $e 20160819 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- GRA __
- $a NV15-27941A $p MZ0
- LZP __
- $b NLK118 $a Pubmed-20170412