• Something wrong with this record ?

Measurement of stray neutron doses inside the treatment room from a proton pencil beam scanning system

N. Mojżeszek, J. Farah, M. Kłodowska, O. Ploc, L. Stolarczyk, MP. Waligórski, P. Olko,

. 2017 ; 34 (-) : 80-84. [pub] 20170125

Language English Country Italy

Document type Journal Article

PURPOSE: To measure the environmental doses from stray neutrons in the vicinity of a solid slab phantom as a function of beam energy, field size and modulation width, using the proton pencil beam scanning (PBS) technique. METHOD: Measurements were carried out using two extended range WENDI-II rem-counters and three tissue equivalent proportional counters. Detectors were suitably placed at different distances around the RW3 slab phantom. Beam irradiation parameters were varied to cover the clinical ranges of proton beam energies (100-220MeV), field sizes ((2×2)-(20×20)cm(2)) and modulation widths (0-15cm). RESULTS: For pristine proton peak irradiations, large variations of neutron H(∗)(10)/D were observed with changes in beam energy and field size, while these were less dependent on modulation widths. H(∗)(10)/D for pristine proton pencil beams varied between 0.04μSvGy(-1) at beam energy 100MeV and a (2×2)cm(2) field at 2.25m distance and 90° angle with respect to the beam axis, and 72.3μSvGy(-1) at beam energy 200MeV and a (20×20) cm(2) field at 1m distance along the beam axis. CONCLUSIONS: The obtained results will be useful in benchmarking Monte Carlo calculations of proton radiotherapy in PBS mode and in estimating the exposure to stray radiation of the patient. Such estimates may be facilitated by the obtained best-fitted simple analytical formulae relating the stray neutron doses at points of interest with beam irradiation parameters.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17013284
003      
CZ-PrNML
005      
20170426094318.0
007      
ta
008      
170413s2017 it f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejmp.2017.01.013 $2 doi
035    __
$a (PubMed)28131732
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Mojżeszek, N $u Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Radzikowskiego 152, 31-342 Krakow, Poland.
245    10
$a Measurement of stray neutron doses inside the treatment room from a proton pencil beam scanning system / $c N. Mojżeszek, J. Farah, M. Kłodowska, O. Ploc, L. Stolarczyk, MP. Waligórski, P. Olko,
520    9_
$a PURPOSE: To measure the environmental doses from stray neutrons in the vicinity of a solid slab phantom as a function of beam energy, field size and modulation width, using the proton pencil beam scanning (PBS) technique. METHOD: Measurements were carried out using two extended range WENDI-II rem-counters and three tissue equivalent proportional counters. Detectors were suitably placed at different distances around the RW3 slab phantom. Beam irradiation parameters were varied to cover the clinical ranges of proton beam energies (100-220MeV), field sizes ((2×2)-(20×20)cm(2)) and modulation widths (0-15cm). RESULTS: For pristine proton peak irradiations, large variations of neutron H(∗)(10)/D were observed with changes in beam energy and field size, while these were less dependent on modulation widths. H(∗)(10)/D for pristine proton pencil beams varied between 0.04μSvGy(-1) at beam energy 100MeV and a (2×2)cm(2) field at 2.25m distance and 90° angle with respect to the beam axis, and 72.3μSvGy(-1) at beam energy 200MeV and a (20×20) cm(2) field at 1m distance along the beam axis. CONCLUSIONS: The obtained results will be useful in benchmarking Monte Carlo calculations of proton radiotherapy in PBS mode and in estimating the exposure to stray radiation of the patient. Such estimates may be facilitated by the obtained best-fitted simple analytical formulae relating the stray neutron doses at points of interest with beam irradiation parameters.
650    _2
$a metoda Monte Carlo $7 D009010
650    _2
$a neutrony $x terapeutické užití $7 D009502
650    _2
$a fantomy radiodiagnostické $7 D019047
650    12
$a protonová terapie $7 D061766
650    12
$a dávka záření $7 D011829
650    _2
$a radiometrie $7 D011874
650    _2
$a celková dávka radioterapie $7 D011879
650    12
$a radiační rozptyl $7 D012542
655    _2
$a časopisecké články $7 D016428
700    1_
$a Farah, J $u Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Radioprotection de l'Homme, BP-17, 92260 Fontenay-aux-Roses, France; Hôpitaux Universitaires Paris-Sud, Pôle Imagerie et Médecine Nucléaire, Hôpital du Kremlin-Bicêtre, 78 Rue Général Leclerc, 94270 Le Kremlin-Bicêtre, France(1). Electronic address: jad.farah@hotmail.fr.
700    1_
$a Kłodowska, M $u Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Radzikowskiego 152, 31-342 Krakow, Poland.
700    1_
$a Ploc, O $u Nuclear Physics Institute, Academy of Sciences of the Czech Republic (NPI), CZ-250 68 Řež, Czech Republic.
700    1_
$a Stolarczyk, L $u Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Radzikowskiego 152, 31-342 Krakow, Poland.
700    1_
$a Waligórski, M P R $u Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Radzikowskiego 152, 31-342 Krakow, Poland; Centre od Oncology, Kraków Division, PL-31-115 Kraków, Poland.
700    1_
$a Olko, P $u Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN), Radzikowskiego 152, 31-342 Krakow, Poland.
773    0_
$w MED00167391 $t Physica medica PM an international journal devoted to the applications of physics to medicine and biology official journal of the Italian Association of Biomedical Physics (AIFB) $x 1724-191X $g Roč. 34, č. - (2017), s. 80-84
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28131732 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170413 $b ABA008
991    __
$a 20170426094636 $b ABA008
999    __
$a ok $b bmc $g 1199749 $s 974062
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 34 $c - $d 80-84 $e 20170125 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
LZP    __
$a Pubmed-20170413

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...