• Something wrong with this record ?

Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations

E. Holt, P. Bohlin-Nizzetto, J. Borůvková, T. Harner, J. Kalina, L. Melymuk, J. Klánová,

. 2017 ; 220 (Pt B) : 1100-1111. [pub] 20161116

Language English Country England, Great Britain

Document type Journal Article

Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (Rs) or to calculate air concentrations (Cair) from PUF-PAS measurements for SVOCs. Cair was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: Rs, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted Rs). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17013391
003      
CZ-PrNML
005      
20170418105752.0
007      
ta
008      
170413s2017 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.envpol.2016.11.030 $2 doi
035    __
$a (PubMed)27865659
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Holt, Eva $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia. Electronic address: holt@recetox.muni.cz.
245    10
$a Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations / $c E. Holt, P. Bohlin-Nizzetto, J. Borůvková, T. Harner, J. Kalina, L. Melymuk, J. Klánová,
520    9_
$a Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (Rs) or to calculate air concentrations (Cair) from PUF-PAS measurements for SVOCs. Cair was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: Rs, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted Rs). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.
650    _2
$a látky znečišťující vzduch $x chemie $7 D000393
650    _2
$a kalibrace $7 D002138
650    _2
$a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
650    _2
$a Evropa $7 D005060
650    _2
$a polyurethany $x chemie $7 D011140
650    _2
$a nejistota $7 D035501
650    _2
$a těkavé organické sloučeniny $x chemie $7 D055549
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bohlin-Nizzetto, Pernilla $u Norwegian Institute for Air Research (NILU), Instituttveien 18, PO Box 100, NO-2027 Kjeller, Norway.
700    1_
$a Borůvková, Jana $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
700    1_
$a Harner, Tom $u Air Quality Processes Research Section, Environment and Climate Change Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4, Canada.
700    1_
$a Kalina, Jiří $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
700    1_
$a Melymuk, Lisa $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
700    1_
$a Klánová, Jana $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
773    0_
$w MED00001554 $t Environmental pollution (Barking, Essex 1987) $x 1873-6424 $g Roč. 220, č. Pt B (2017), s. 1100-1111
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27865659 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170413 $b ABA008
991    __
$a 20170418110100 $b ABA008
999    __
$a ok $b bmc $g 1199856 $s 974169
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 220 $c Pt B $d 1100-1111 $e 20161116 $i 1873-6424 $m Environmental pollution (1987) $n Environ. pollut. (1987) $x MED00001554
LZP    __
$a Pubmed-20170413

Find record

Citation metrics

Logged in users only

Archiving options

Loading data ...