Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations
E. Holt, P. Bohlin-Nizzetto, J. Borůvková, T. Harner, J. Kalina, L. Melymuk, J. Klánová,
Language English Country England, Great Britain
Document type Journal Article
- MeSH
- Calibration MeSH
- Air Pollutants chemistry MeSH
- Environmental Monitoring instrumentation methods MeSH
- Uncertainty MeSH
- Polyurethanes chemistry MeSH
- Volatile Organic Compounds chemistry MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Europe MeSH
Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (Rs) or to calculate air concentrations (Cair) from PUF-PAS measurements for SVOCs. Cair was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: Rs, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted Rs). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013391
- 003
- CZ-PrNML
- 005
- 20170418105752.0
- 007
- ta
- 008
- 170413s2017 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.envpol.2016.11.030 $2 doi
- 035 __
- $a (PubMed)27865659
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Holt, Eva $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia. Electronic address: holt@recetox.muni.cz.
- 245 10
- $a Using long-term air monitoring of semi-volatile organic compounds to evaluate the uncertainty in polyurethane-disk passive sampler-derived air concentrations / $c E. Holt, P. Bohlin-Nizzetto, J. Borůvková, T. Harner, J. Kalina, L. Melymuk, J. Klánová,
- 520 9_
- $a Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (Rs) or to calculate air concentrations (Cair) from PUF-PAS measurements for SVOCs. Cair was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: Rs, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted Rs). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.
- 650 _2
- $a látky znečišťující vzduch $x chemie $7 D000393
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
- 650 _2
- $a Evropa $7 D005060
- 650 _2
- $a polyurethany $x chemie $7 D011140
- 650 _2
- $a nejistota $7 D035501
- 650 _2
- $a těkavé organické sloučeniny $x chemie $7 D055549
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Bohlin-Nizzetto, Pernilla $u Norwegian Institute for Air Research (NILU), Instituttveien 18, PO Box 100, NO-2027 Kjeller, Norway.
- 700 1_
- $a Borůvková, Jana $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
- 700 1_
- $a Harner, Tom $u Air Quality Processes Research Section, Environment and Climate Change Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4, Canada.
- 700 1_
- $a Kalina, Jiří $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
- 700 1_
- $a Melymuk, Lisa $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
- 700 1_
- $a Klánová, Jana $u RECETOX -Research Centre for Toxic Compounds in the Environment, Masaryk University, Kamenice 753/5, 625 00 Brno, Czechia.
- 773 0_
- $w MED00001554 $t Environmental pollution (Barking, Essex 1987) $x 1873-6424 $g Roč. 220, č. Pt B (2017), s. 1100-1111
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27865659 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170418110100 $b ABA008
- 999 __
- $a ok $b bmc $g 1199856 $s 974169
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 220 $c Pt B $d 1100-1111 $e 20161116 $i 1873-6424 $m Environmental pollution (1987) $n Environ. pollut. (1987) $x MED00001554
- LZP __
- $a Pubmed-20170413