Something wrong with this record ?
A review of superior vena cava flow measurement in the neonate by functional echocardiography
M. McGovern, J. Miletin,
Language English Country Norway
Document type Journal Article, Review
PubMed
27611695
DOI
10.1111/apa.13584
Knihovny.cz E-resources
- MeSH
- Echocardiography, Doppler methods MeSH
- Humans MeSH
- Neonatology methods MeSH
- Infant, Newborn MeSH
- Blood Flow Velocity MeSH
- Vena Cava, Superior diagnostic imaging physiopathology MeSH
- Check Tag
- Humans MeSH
- Infant, Newborn MeSH
- Publication type
- Journal Article MeSH
- Review MeSH
Neonatologists have begun using superior vena cava flow as assessed by functional echocardiography to facilitate real-time decision-making on cardiovascular care. This review aims to describe the basis of the technique, summarise the evidence for its use and compare the technique to existing clinical, biochemical and radiological techniques for assessing neonatal circulatory status. CONCLUSION: Although echocardiographic measurements of superior vena cava flow, like other measures of perfusion, are not perfect, their noninvasive nature and ability to facilitate real-time decision-making means that at present, they remain the best available methodology of monitoring central perfusion in the neonatal population.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013548
- 003
- CZ-PrNML
- 005
- 20170425100020.0
- 007
- ta
- 008
- 170413s2017 no f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/apa.13584 $2 doi
- 035 __
- $a (PubMed)27611695
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a no
- 100 1_
- $a McGovern, Matthew $u Neonatology Department, Coombe Women and Infant University Hospital, Dublin, Ireland.
- 245 12
- $a A review of superior vena cava flow measurement in the neonate by functional echocardiography / $c M. McGovern, J. Miletin,
- 520 9_
- $a Neonatologists have begun using superior vena cava flow as assessed by functional echocardiography to facilitate real-time decision-making on cardiovascular care. This review aims to describe the basis of the technique, summarise the evidence for its use and compare the technique to existing clinical, biochemical and radiological techniques for assessing neonatal circulatory status. CONCLUSION: Although echocardiographic measurements of superior vena cava flow, like other measures of perfusion, are not perfect, their noninvasive nature and ability to facilitate real-time decision-making means that at present, they remain the best available methodology of monitoring central perfusion in the neonatal population.
- 650 _2
- $a rychlost toku krve $7 D001783
- 650 _2
- $a dopplerovská echokardiografie $x metody $7 D015150
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a novorozenec $7 D007231
- 650 _2
- $a neonatologie $x metody $7 D009359
- 650 _2
- $a vena cava superior $x diagnostické zobrazování $x patofyziologie $7 D014683
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Miletin, Jan $u Neonatology Department, Coombe Women and Infant University Hospital, Dublin, Ireland. Institute for the Care of Mother and Child, Prague, Czech Republic. 3rd School of Medicine, Charles University, Prague, Czech Republic. UCD School of Medicine and Medical Sciences, Dublin, Ireland.
- 773 0_
- $w MED00009036 $t Acta paediatrica (Oslo, Norway 1992) $x 1651-2227 $g Roč. 106, č. 1 (2017), s. 22-29
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27611695 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170425100337 $b ABA008
- 999 __
- $a ok $b bmc $g 1200013 $s 974326
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 106 $c 1 $d 22-29 $e 20160928 $i 1651-2227 $m Acta paediatrica (Oslo) $n Acta Paediatr $x MED00009036
- LZP __
- $a Pubmed-20170413