The importance of electrode position in visual electrophysiology

A. Kurtenbach, S. Kramer, T. Strasser, E. Zrenner, H. Langrová,

. 2017 ; 134 (2) : 129-134. [pub] 20170221

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc17023273
E-zdroje Online Plný text

NLK ProQuest Central od 1997-03-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2011-02-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-03-01 do Před 1 rokem

PURPOSE: The DTL fibre electrode is commonly used to record the electric potentials elicited by stimulation of the retina. Two positions are commonly used: it is placed either on the cornea along the lower lid or in the conjunctival fornix. The PERG and OPs have previously been examined and compared under both conditions. The aim of this study was to examine the ERG, flicker response and on-off responses with differing electrode positions. METHODS: Before recruitment, all subjects underwent an ophthalmological examination. We enrolled 13 normal control subjects into the study aged 13-64 years, all with a visual acuity of ≥1.0. We recorded scotopic and photopic ERGs, flicker and on-off responses, for both electrode positions. On the first day, one eye had the electrode placed on the cornea along the lower lid and the other eye had it positioned in the conjunctival sac. On a second day, the recordings were repeated with the alternative electrode placements. RESULTS: ERG, on-off and flicker responses were all smaller by between 20 and 25% when the DTL electrode was positioned in the conjunctival sac, compared to when it was positioned on the cornea, as did the scatter in the data points. This indicates that there is no advantage clinically for one or the other placement. CONCLUSIONS: Our results confirm other reports examining the effect of electrode position on electrophysiological potentials. When recording with the DTL electrode, it is important to ensure that it is placed at the same position in repeat recordings or in multicentre trials and that it is stable and does not move during recording.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17023273
003      
CZ-PrNML
005      
20170831111017.0
007      
ta
008      
170720s2017 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10633-017-9579-9 $2 doi
035    __
$a (PubMed)28224239
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Kurtenbach, A $u Institute for Ophthalmic Research, Centre for Ophthalmology, University of Tübingen, Elfriede-Aulhorn Strasse 7, 72076, Tübingen, Germany. anne.kurtenbach@uni-tuebingen.de.
245    14
$a The importance of electrode position in visual electrophysiology / $c A. Kurtenbach, S. Kramer, T. Strasser, E. Zrenner, H. Langrová,
520    9_
$a PURPOSE: The DTL fibre electrode is commonly used to record the electric potentials elicited by stimulation of the retina. Two positions are commonly used: it is placed either on the cornea along the lower lid or in the conjunctival fornix. The PERG and OPs have previously been examined and compared under both conditions. The aim of this study was to examine the ERG, flicker response and on-off responses with differing electrode positions. METHODS: Before recruitment, all subjects underwent an ophthalmological examination. We enrolled 13 normal control subjects into the study aged 13-64 years, all with a visual acuity of ≥1.0. We recorded scotopic and photopic ERGs, flicker and on-off responses, for both electrode positions. On the first day, one eye had the electrode placed on the cornea along the lower lid and the other eye had it positioned in the conjunctival sac. On a second day, the recordings were repeated with the alternative electrode placements. RESULTS: ERG, on-off and flicker responses were all smaller by between 20 and 25% when the DTL electrode was positioned in the conjunctival sac, compared to when it was positioned on the cornea, as did the scatter in the data points. This indicates that there is no advantage clinically for one or the other placement. CONCLUSIONS: Our results confirm other reports examining the effect of electrode position on electrophysiological potentials. When recording with the DTL electrode, it is important to ensure that it is placed at the same position in repeat recordings or in multicentre trials and that it is stable and does not move during recording.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a studie případů a kontrol $7 D016022
650    _2
$a rohovka $x fyziologie $7 D003315
650    _2
$a elektrofyziologie $x metody $7 D004594
650    _2
$a elektroretinografie $x metody $7 D004596
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    12
$a mikroelektrody $7 D008839
650    _2
$a lidé středního věku $7 D008875
650    _2
$a světelná stimulace $x metody $7 D010775
650    _2
$a retina $x fyziologie $7 D012160
650    _2
$a zraková ostrost $7 D014792
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kramer, S $u Institute for Ophthalmic Research, Centre for Ophthalmology, University of Tübingen, Elfriede-Aulhorn Strasse 7, 72076, Tübingen, Germany.
700    1_
$a Strasser, T $u Institute for Ophthalmic Research, Centre for Ophthalmology, University of Tübingen, Elfriede-Aulhorn Strasse 7, 72076, Tübingen, Germany.
700    1_
$a Zrenner, E $u Institute for Ophthalmic Research, Centre for Ophthalmology, University of Tübingen, Elfriede-Aulhorn Strasse 7, 72076, Tübingen, Germany. Werner Reichardt Centre for Integrative Neuroscience (CIN), University of Tübingen, Tübingen, Germany.
700    1_
$a Langrová, H $u University Eye Hospital, Hradec Králové, Czech Republic.
773    0_
$w MED00010453 $t Documenta ophthalmologica. Advances in ophthalmology $x 1573-2622 $g Roč. 134, č. 2 (2017), s. 129-134
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28224239 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170720 $b ABA008
991    __
$a 20170831111607 $b ABA008
999    __
$a ok $b bmc $g 1238954 $s 984186
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 134 $c 2 $d 129-134 $e 20170221 $i 1573-2622 $m Documenta ophthalmologica $n Doc Ophthalmol $x MED00010453
LZP    __
$a Pubmed-20170720

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...