Rehabilitation of aged drinking water pipes is an extensive renovation and increasingly topical in many European cities. Spray-on-lining of drinking water pipes is an alternative cost-effective rehabilitation technology in which the insides of pipes are relined with organic polymer. A commonly used polymer is epoxy resin consisting of monomer bisphenol A (BPA). Leaching of BPA from epoxy lining to drinking water has been a concern among public and authorities. Currently epoxy lining is not recommended in some countries. BPA leaching has been demonstrated in laboratory studies but the behavior and ageing process of epoxy lining in situ is not well known. In this study 6 locations with different age epoxy linings of drinking water pipes done using two distinct technologies were studied. While bisphenol F, 4-n-nonylphenol, and 4-t-octylphenol were rarely found and in trace concentrations, BPA was detected in majority of samples. Pipes lined with the older technology (LSE) leached more BPA than those with more recent technology (DonPro): maxima in cold water were 0.25 μg/L and 10 ng/L, respectively. Incubation of water in pipes 8-10 h prior to sampling increased BPA concentration in cold water 1.1-43-fold. Hot water temperature caused even more BPA leaching - at maximum 23.5 μg/L. The influence of ageing of epoxy lining on BPA leaching on could be shown in case of LSE technology: locations with 8-9 years old lining leached 4-20-fold more BPA compared to a location with 2-year-old lining. Analysis of metals showed that epoxy lining can reduce especially iron concentration in water. No significant burden to water could be shown by the analyzed 72 volatile organic compounds, including epichlorhydrin, precursor used in epoxy resin. Estrogenicity was detected in water samples with the highest BPA loads. Comparable responses of two yeast bioreporters (estrogen receptor α and BPA-targeted) indicated that bisphenol-like compounds were the main cause of estrogenicity. Compared to the estimated average daily BPA exposure, additional BPA load via cold drinking water in the studied locations was low, maximum 8.7%. However, hot water should also be considered as exposure source due to higher BPA concentrations. Epoxy lined locations should be monitored in future in order to evaluate ageing process and control increasing leaching of potentially harmful chemicals.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17023838
- 003
- CZ-PrNML
- 005
- 20170720123559.0
- 007
- ta
- 008
- 170720s2016 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.watres.2016.07.027 $2 doi
- 035 __
- $a (PubMed)27448038
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Rajasärkkä, Johanna $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic. Electronic address: johanna.rajasarkka@gmail.com.
- 245 10
- $a Drinking water contaminants from epoxy resin-coated pipes: A field study / $c J. Rajasärkkä, M. Pernica, J. Kuta, J. Lašňák, Z. Šimek, L. Bláha,
- 520 9_
- $a Rehabilitation of aged drinking water pipes is an extensive renovation and increasingly topical in many European cities. Spray-on-lining of drinking water pipes is an alternative cost-effective rehabilitation technology in which the insides of pipes are relined with organic polymer. A commonly used polymer is epoxy resin consisting of monomer bisphenol A (BPA). Leaching of BPA from epoxy lining to drinking water has been a concern among public and authorities. Currently epoxy lining is not recommended in some countries. BPA leaching has been demonstrated in laboratory studies but the behavior and ageing process of epoxy lining in situ is not well known. In this study 6 locations with different age epoxy linings of drinking water pipes done using two distinct technologies were studied. While bisphenol F, 4-n-nonylphenol, and 4-t-octylphenol were rarely found and in trace concentrations, BPA was detected in majority of samples. Pipes lined with the older technology (LSE) leached more BPA than those with more recent technology (DonPro): maxima in cold water were 0.25 μg/L and 10 ng/L, respectively. Incubation of water in pipes 8-10 h prior to sampling increased BPA concentration in cold water 1.1-43-fold. Hot water temperature caused even more BPA leaching - at maximum 23.5 μg/L. The influence of ageing of epoxy lining on BPA leaching on could be shown in case of LSE technology: locations with 8-9 years old lining leached 4-20-fold more BPA compared to a location with 2-year-old lining. Analysis of metals showed that epoxy lining can reduce especially iron concentration in water. No significant burden to water could be shown by the analyzed 72 volatile organic compounds, including epichlorhydrin, precursor used in epoxy resin. Estrogenicity was detected in water samples with the highest BPA loads. Comparable responses of two yeast bioreporters (estrogen receptor α and BPA-targeted) indicated that bisphenol-like compounds were the main cause of estrogenicity. Compared to the estimated average daily BPA exposure, additional BPA load via cold drinking water in the studied locations was low, maximum 8.7%. However, hot water should also be considered as exposure source due to higher BPA concentrations. Epoxy lined locations should be monitored in future in order to evaluate ageing process and control increasing leaching of potentially harmful chemicals.
- 650 _2
- $a benzhydrylové sloučeniny $7 D001559
- 650 _2
- $a velkoměsta $7 D002947
- 650 _2
- $a pitná voda $x chemie $7 D060766
- 650 12
- $a epoxidové pryskyřice $7 D004853
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a fenoly $x chemie $7 D010636
- 650 _2
- $a chemické látky znečišťující vodu $7 D014874
- 650 _2
- $a znečištění vody $7 D014876
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Pernica, Marek $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic.
- 700 1_
- $a Kuta, Jan $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic.
- 700 1_
- $a Lašňák, Jonáš $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic.
- 700 1_
- $a Šimek, Zdenĕk $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic.
- 700 1_
- $a Bláha, Luděk $u Masaryk University, Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Kamenice 753/5, Pavillion A29, 625 00, Brno, Czech Republic.
- 773 0_
- $w MED00008324 $t Water research $x 1879-2448 $g Roč. 103, č. - (2016), s. 133-40
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27448038 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170720 $b ABA008
- 991 __
- $a 20170720124052 $b ABA008
- 999 __
- $a ok $b bmc $g 1239519 $s 984751
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 103 $c - $d 133-40 $e 20160715 $i 1879-2448 $m Water research $n Water Res $x MED00008324
- LZP __
- $a Pubmed-20170720