• Je něco špatně v tomto záznamu ?

Comparison of different tissue clearing methods and 3D imaging techniques for visualization of GFP-expressing mouse embryos and embryonic hearts

H. Kolesová, M. Čapek, B. Radochová, J. Janáček, D. Sedmera,

. 2016 ; 146 (2) : 141-52. [pub] 20160504

Jazyk angličtina Země Německo

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc17024013
E-zdroje Online Plný text

NLK ProQuest Central od 1997-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2000-01-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest) od 1997-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-01-01 do Před 1 rokem
Public Health Database (ProQuest) od 1997-01-01 do Před 1 rokem

Our goal was to find an optimal tissue clearing protocol for whole-mount imaging of embryonic and adult hearts and whole embryos of transgenic mice that would preserve green fluorescent protein GFP fluorescence and permit comparison of different currently available 3D imaging modalities. We tested various published organic solvent- or water-based clearing protocols intended to preserve GFP fluorescence in central nervous system: tetrahydrofuran dehydration and dibenzylether protocol (DBE), SCALE, CLARITY, and CUBIC and evaluated their ability to render hearts and whole embryos transparent. DBE clearing protocol did not preserve GFP fluorescence; in addition, DBE caused considerable tissue-shrinking artifacts compared to the gold standard BABB protocol. The CLARITY method considerably improved tissue transparency at later stages, but also decreased GFP fluorescence intensity. The SCALE clearing resulted in sufficient tissue transparency up to ED12.5; at later stages the useful depth of imaging was limited by tissue light scattering. The best method for the cardiac specimens proved to be the CUBIC protocol, which preserved GFP fluorescence well, and cleared the specimens sufficiently even at the adult stages. In addition, CUBIC decolorized the blood and myocardium by removing tissue iron. Good 3D renderings of whole fetal hearts and embryos were obtained with optical projection tomography and selective plane illumination microscopy, although at resolutions lower than with a confocal microscope. Comparison of five tissue clearing protocols and three imaging methods for study of GFP mouse embryos and hearts shows that the optimal method depends on stage and level of detail required.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17024013
003      
CZ-PrNML
005      
20170720122828.0
007      
ta
008      
170720s2016 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00418-016-1441-8 $2 doi
035    __
$a (PubMed)27145961
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Kolesová, Hana $u Institute of Anatomy, First Faculty of Medicine, Charles University in Prague, U Nemocnice 3, 128 00, Prague 2, Czech Republic.
245    10
$a Comparison of different tissue clearing methods and 3D imaging techniques for visualization of GFP-expressing mouse embryos and embryonic hearts / $c H. Kolesová, M. Čapek, B. Radochová, J. Janáček, D. Sedmera,
520    9_
$a Our goal was to find an optimal tissue clearing protocol for whole-mount imaging of embryonic and adult hearts and whole embryos of transgenic mice that would preserve green fluorescent protein GFP fluorescence and permit comparison of different currently available 3D imaging modalities. We tested various published organic solvent- or water-based clearing protocols intended to preserve GFP fluorescence in central nervous system: tetrahydrofuran dehydration and dibenzylether protocol (DBE), SCALE, CLARITY, and CUBIC and evaluated their ability to render hearts and whole embryos transparent. DBE clearing protocol did not preserve GFP fluorescence; in addition, DBE caused considerable tissue-shrinking artifacts compared to the gold standard BABB protocol. The CLARITY method considerably improved tissue transparency at later stages, but also decreased GFP fluorescence intensity. The SCALE clearing resulted in sufficient tissue transparency up to ED12.5; at later stages the useful depth of imaging was limited by tissue light scattering. The best method for the cardiac specimens proved to be the CUBIC protocol, which preserved GFP fluorescence well, and cleared the specimens sufficiently even at the adult stages. In addition, CUBIC decolorized the blood and myocardium by removing tissue iron. Good 3D renderings of whole fetal hearts and embryos were obtained with optical projection tomography and selective plane illumination microscopy, although at resolutions lower than with a confocal microscope. Comparison of five tissue clearing protocols and three imaging methods for study of GFP mouse embryos and hearts shows that the optimal method depends on stage and level of detail required.
650    _2
$a zvířata $7 D000818
650    _2
$a zelené fluorescenční proteiny $x analýza $x biosyntéza $x genetika $7 D049452
650    _2
$a srdce $x embryologie $7 D006321
650    _2
$a zobrazování trojrozměrné $x metody $7 D021621
650    _2
$a myši $7 D051379
650    _2
$a myši transgenní $7 D008822
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Čapek, Martin $u Institute of Physiology, The Czech Academy of Sciences, 142 20, Prague, Czech Republic.
700    1_
$a Radochová, Barbora $u Institute of Physiology, The Czech Academy of Sciences, 142 20, Prague, Czech Republic.
700    1_
$a Janáček, Jiří $u Institute of Physiology, The Czech Academy of Sciences, 142 20, Prague, Czech Republic.
700    1_
$a Sedmera, David $u Institute of Anatomy, First Faculty of Medicine, Charles University in Prague, U Nemocnice 3, 128 00, Prague 2, Czech Republic. david.sedmera@lf1.cuni.cz. Institute of Physiology, The Czech Academy of Sciences, 142 20, Prague, Czech Republic. david.sedmera@lf1.cuni.cz.
773    0_
$w MED00002042 $t Histochemistry and cell biology $x 1432-119X $g Roč. 146, č. 2 (2016), s. 141-52
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27145961 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170720 $b ABA008
991    __
$a 20170720123321 $b ABA008
999    __
$a ok $b bmc $g 1239694 $s 984926
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 146 $c 2 $d 141-52 $e 20160504 $i 1432-119X $m Histochemistry and cell biology $n Histochem Cell Biol $x MED00002042
LZP    __
$a Pubmed-20170720

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...