Something wrong with this record ?
Fused silica capillaries with two segments of different internal diameters and inner surface roughnesses prepared by etching with supercritical water and used for volume coupling electrophoresis
M. Horká, P. Karásek, M. Roth, K. Šlais,
Language English Country Germany
Document type Journal Article
Grant support
NV16-29916A
MZ0
CEP Register
Digital library NLK
Full text - Article
NLK
Medline Complete (EBSCOhost)
from 2012-10-01 to 1 year ago
- MeSH
- Equipment Design MeSH
- Electrophoresis, Capillary instrumentation methods MeSH
- Hydrogen-Ion Concentration MeSH
- Limit of Detection MeSH
- Silicon Dioxide chemistry MeSH
- Surface Properties MeSH
- Particle Size MeSH
- Water chemistry MeSH
- Publication type
- Journal Article MeSH
In this work, single-piece fused silica capillaries with two different internal diameter segments featuring different inner surface roughness were prepared by new etching technology with supercritical water and used for volume coupling electrophoresis. The concept of separation and online pre-concentration of analytes in high conductivity matrix is based on the online large-volume sample pre-concentration by the combination of transient isotachophoretic stacking and sweeping of charged proteins in micellar electrokinetic chromatography using non-ionogenic surfactant. The modified surface roughness step helped to the significant narrowing of the zones of examined analytes. The sweeping and separating steps were accomplished simultaneously by the use of phosphate buffer (pH 7) containing ethanol, non-ionogenic surfactant Brij 35, and polyethylene glycol (PEG 10000) after sample injection. Sample solution of a large volume (maximum 3.7 μL) dissolved in physiological saline solution was injected into the wider end of capillary with inlet inner diameter from 150, 185 or 218 μm. The calibration plots were linear (R(2) ∼ 0.9993) over a 0.060-1 μg/mL range for the proteins used, albumin and cytochrome c. The peak area RSDs from at least 20 independent measuremens were below 3.2%. This online pre-concentration technique produced a more than 196-fold increase in sensitivity, and it can be applied for detection of, e.g. the presence of albumin in urine (0.060 μg/mL).
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17031018
- 003
- CZ-PrNML
- 005
- 20171025123430.0
- 007
- ta
- 008
- 171025s2017 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201600499 $2 doi
- 035 __
- $a (PubMed)28229522
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Horká, Marie $u Institute of Analytical Chemistry of the CAS, v. v. i., Brno, Czech Republic.
- 245 10
- $a Fused silica capillaries with two segments of different internal diameters and inner surface roughnesses prepared by etching with supercritical water and used for volume coupling electrophoresis / $c M. Horká, P. Karásek, M. Roth, K. Šlais,
- 520 9_
- $a In this work, single-piece fused silica capillaries with two different internal diameter segments featuring different inner surface roughness were prepared by new etching technology with supercritical water and used for volume coupling electrophoresis. The concept of separation and online pre-concentration of analytes in high conductivity matrix is based on the online large-volume sample pre-concentration by the combination of transient isotachophoretic stacking and sweeping of charged proteins in micellar electrokinetic chromatography using non-ionogenic surfactant. The modified surface roughness step helped to the significant narrowing of the zones of examined analytes. The sweeping and separating steps were accomplished simultaneously by the use of phosphate buffer (pH 7) containing ethanol, non-ionogenic surfactant Brij 35, and polyethylene glycol (PEG 10000) after sample injection. Sample solution of a large volume (maximum 3.7 μL) dissolved in physiological saline solution was injected into the wider end of capillary with inlet inner diameter from 150, 185 or 218 μm. The calibration plots were linear (R(2) ∼ 0.9993) over a 0.060-1 μg/mL range for the proteins used, albumin and cytochrome c. The peak area RSDs from at least 20 independent measuremens were below 3.2%. This online pre-concentration technique produced a more than 196-fold increase in sensitivity, and it can be applied for detection of, e.g. the presence of albumin in urine (0.060 μg/mL).
- 650 _2
- $a elektroforéza kapilární $x přístrojové vybavení $x metody $7 D019075
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a velikost částic $7 D010316
- 650 _2
- $a oxid křemičitý $x chemie $7 D012822
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 650 _2
- $a voda $x chemie $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Karásek, Pavel $u Institute of Analytical Chemistry of the CAS, v. v. i., Brno, Czech Republic.
- 700 1_
- $a Roth, Michal $u Institute of Analytical Chemistry of the CAS, v. v. i., Brno, Czech Republic.
- 700 1_
- $a Šlais, Karel $u Institute of Analytical Chemistry of the CAS, v. v. i., Brno, Czech Republic.
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 38, č. 9-10 (2017), s. 1260-1267
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28229522 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20171025 $b ABA008
- 991 __
- $a 20171025123512 $b ABA008
- 999 __
- $a ok $b bmc $g 1254611 $s 992045
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 38 $c 9-10 $d 1260-1267 $e 20170316 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- GRA __
- $a NV16-29916A $p MZ0
- LZP __
- $a Pubmed-20171025