Applicability of low-flow atmospheric pressure chemical ionization and photoionization mass spectrometry with a microfabricated nebulizer for neutral lipids

V. Vrkoslav, B. Rumlová, T. Strmeň, P. Nekvasilová, M. Šulc, J. Cvačka,

. 2018 ; 32 (8) : 639-648.

Language English Country Great Britain

Document type Journal Article

RATIONALE: Mass spectrometry with atmospheric pressure chemical ionization (APCI) or photoionization (APPI) is widely used for neutral lipids involved in many fundamental processes in living organisms. Commercial APCI and APPI sources operate at high flow rates compatible with conventional high-performance liquid chromatography (HPLC). However, lipid analysis is often limited by a small amount of sample, which requires low flow rate separations like capillary or micro-HPLC. Therefore, APCI and APPI suitable for microliter-per-minute flow rates need to be developed and applied for neutral lipids. METHODS: A micro-APCI/APPI source with a heated chip nebulizer was assembled and mounted on a Thermo ion trap instrument. The ion source operated in APCI, APPI or dual mode was optimized for low microliter-per-minute sample flow rates. The source performance was investigated for squalene, wax esters, fatty acid methyl esters, triacylglycerols, and cholesterol. RESULTS: The ion source behaved as a mass-flow-sensitive detector. Direct infusion of methyl oleate showed superior analytical figures of merit when compared with high-flow ion sources. A detection limit of 200 pmol/mL and a linear dynamic range spanning three orders of magnitude were measured for micro-APCI. The mass spectra of most lipids differed from high flow rate spectra. Unlike micro-APCI, micro-APPI spectra were complicated by odd-electron species. Dual APCI/APPI mode did not show any benefits for neutral lipids. Applications for lipid samples were demonstrated. CONCLUSIONS: Micro-APCI-MS is a useful detection technique for neutral lipids at microliter-per-minute flow rates. It offers high sensitivity and high quality of spectra in direct infusion mode and promises successful utilization in capillary and micro-HPLC applications.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18009994
003      
CZ-PrNML
005      
20180406093133.0
007      
ta
008      
180404s2018 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/rcm.8086 $2 doi
035    __
$a (PubMed)29457286
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Vrkoslav, Vladimír $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic.
245    10
$a Applicability of low-flow atmospheric pressure chemical ionization and photoionization mass spectrometry with a microfabricated nebulizer for neutral lipids / $c V. Vrkoslav, B. Rumlová, T. Strmeň, P. Nekvasilová, M. Šulc, J. Cvačka,
520    9_
$a RATIONALE: Mass spectrometry with atmospheric pressure chemical ionization (APCI) or photoionization (APPI) is widely used for neutral lipids involved in many fundamental processes in living organisms. Commercial APCI and APPI sources operate at high flow rates compatible with conventional high-performance liquid chromatography (HPLC). However, lipid analysis is often limited by a small amount of sample, which requires low flow rate separations like capillary or micro-HPLC. Therefore, APCI and APPI suitable for microliter-per-minute flow rates need to be developed and applied for neutral lipids. METHODS: A micro-APCI/APPI source with a heated chip nebulizer was assembled and mounted on a Thermo ion trap instrument. The ion source operated in APCI, APPI or dual mode was optimized for low microliter-per-minute sample flow rates. The source performance was investigated for squalene, wax esters, fatty acid methyl esters, triacylglycerols, and cholesterol. RESULTS: The ion source behaved as a mass-flow-sensitive detector. Direct infusion of methyl oleate showed superior analytical figures of merit when compared with high-flow ion sources. A detection limit of 200 pmol/mL and a linear dynamic range spanning three orders of magnitude were measured for micro-APCI. The mass spectra of most lipids differed from high flow rate spectra. Unlike micro-APCI, micro-APPI spectra were complicated by odd-electron species. Dual APCI/APPI mode did not show any benefits for neutral lipids. Applications for lipid samples were demonstrated. CONCLUSIONS: Micro-APCI-MS is a useful detection technique for neutral lipids at microliter-per-minute flow rates. It offers high sensitivity and high quality of spectra in direct infusion mode and promises successful utilization in capillary and micro-HPLC applications.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Rumlová, Barbora $u Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic.
700    1_
$a Strmeň, Timotej $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic. Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic.
700    1_
$a Nekvasilová, Pavlína $u Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic.
700    1_
$a Šulc, Miloslav $u Czech University of Life Sciences, Faculty of Agrobiology Natural and Food Resources, Department of Chemistry, Kamýcká 129, CZ-165 00, Prague 6, Czech Republic.
700    1_
$a Cvačka, Josef $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic. Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic.
773    0_
$w MED00004050 $t Rapid communications in mass spectrometry RCM $x 1097-0231 $g Roč. 32, č. 8 (2018), s. 639-648
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29457286 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180404 $b ABA008
991    __
$a 20180406093215 $b ABA008
999    __
$a ind $b bmc $g 1287479 $s 1006806
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 32 $c 8 $d 639-648 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a Pubmed-20180404

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...