• Je něco špatně v tomto záznamu ?

Sub-1min separation in sequential injection chromatography for determination of synthetic water-soluble dyes in pharmaceutical formulation

P. Davletbaeva, P. Chocholouš, A. Bulatov, D. Šatínský, P. Solich,

. 2017 ; 143 (-) : 123-129. [pub] 20170530

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18010511

Sequential Injection Chromatography (SIC) evolved from fast and automated non-separation Sequential Injection Analysis (SIA) into chromatographic separation method for multi-element analysis. However, the speed of the measurement (sample throughput) is due to chromatography significantly reduced. In this paper, a sub-1min separation using medium polar cyano monolithic column (5mm×4.6mm) resulted in fast and green separation with sample throughput comparable with non-separation flow methods The separation of three synthetic water-soluble dyes (sunset yellow FCF, carmoisine and green S) was in a gradient elution mode (0.02% ammonium acetate, pH 6.7 - water) with flow rate of 3.0mLmin-1corresponding with sample throughput of 30h-1. Spectrophotometric detection wavelengths were set to 480, 516 and 630nm and 10Hz data collection rate. The performance of the separation was described and discussed (peak capacities 3.48-7.67, peak symmetries 1.72-1.84 and resolutions 1.42-1.88). The method was represented by validation parameters: LODs of 0.15-0.35mgL-1, LOQs of 0.50-1.25mgL-1, calibration ranges 0.50-150.00mgL-1(r>0.998) and repeatability at 10.0mgL-1of RSD≤0.98% (n=6). The method was used for determination of the dyes in "forest berries" colored pharmaceutical cough-cold formulation. The sample matrix - pharmaceuticals and excipients were not interfering with vis determination because of no retention in the separation column and colorless nature. The results proved the concept of fast and green chromatography approach using very short medium polar monolithic column in SIC.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18010511
003      
CZ-PrNML
005      
20180404142058.0
007      
ta
008      
180404s2017 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2017.05.036 $2 doi
035    __
$a (PubMed)28586724
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Davletbaeva, Polina $u Department of Analytical Chemistry, Institute of Chemistry, St. Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia.
245    10
$a Sub-1min separation in sequential injection chromatography for determination of synthetic water-soluble dyes in pharmaceutical formulation / $c P. Davletbaeva, P. Chocholouš, A. Bulatov, D. Šatínský, P. Solich,
520    9_
$a Sequential Injection Chromatography (SIC) evolved from fast and automated non-separation Sequential Injection Analysis (SIA) into chromatographic separation method for multi-element analysis. However, the speed of the measurement (sample throughput) is due to chromatography significantly reduced. In this paper, a sub-1min separation using medium polar cyano monolithic column (5mm×4.6mm) resulted in fast and green separation with sample throughput comparable with non-separation flow methods The separation of three synthetic water-soluble dyes (sunset yellow FCF, carmoisine and green S) was in a gradient elution mode (0.02% ammonium acetate, pH 6.7 - water) with flow rate of 3.0mLmin-1corresponding with sample throughput of 30h-1. Spectrophotometric detection wavelengths were set to 480, 516 and 630nm and 10Hz data collection rate. The performance of the separation was described and discussed (peak capacities 3.48-7.67, peak symmetries 1.72-1.84 and resolutions 1.42-1.88). The method was represented by validation parameters: LODs of 0.15-0.35mgL-1, LOQs of 0.50-1.25mgL-1, calibration ranges 0.50-150.00mgL-1(r>0.998) and repeatability at 10.0mgL-1of RSD≤0.98% (n=6). The method was used for determination of the dyes in "forest berries" colored pharmaceutical cough-cold formulation. The sample matrix - pharmaceuticals and excipients were not interfering with vis determination because of no retention in the separation column and colorless nature. The results proved the concept of fast and green chromatography approach using very short medium polar monolithic column in SIC.
650    _2
$a farmaceutická chemie $x metody $7 D002626
650    _2
$a chromatografie $7 D002845
650    _2
$a barvicí látky $7 D004396
650    _2
$a příprava léků $7 D004339
650    _2
$a voda $7 D014867
655    _2
$a časopisecké články $7 D016428
700    1_
$a Chocholouš, Petr $u Department of Analytical Chemistry, Charles University, Faculty of Pharmacy in Hradec Králové, Heyrovského 1203, 500 05 Hradec Králové, Czechia. Electronic address: petr.chocholous@faf.cuni.cz.
700    1_
$a Bulatov, Andrey $u Department of Analytical Chemistry, Institute of Chemistry, St. Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia.
700    1_
$a Šatínský, Dalibor $u Department of Analytical Chemistry, Charles University, Faculty of Pharmacy in Hradec Králové, Heyrovského 1203, 500 05 Hradec Králové, Czechia.
700    1_
$a Solich, Petr $u Department of Analytical Chemistry, Charles University, Faculty of Pharmacy in Hradec Králové, Heyrovského 1203, 500 05 Hradec Králové, Czechia.
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 143, č. - (2017), s. 123-129
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28586724 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180404 $b ABA008
991    __
$a 20180404142138 $b ABA008
999    __
$a ok $b bmc $g 1287996 $s 1007323
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 143 $c - $d 123-129 $e 20170530 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20180404

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...