Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode

A. Michaelidesová, J. Vachelová, M. Puchalska, KP. Brabcová, V. Vondráček, L. Sihver, M. Davídková,

. 2017 ; 40 (2) : 359-368. [pub] 20170320

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18010737
E-zdroje Online Plný text

NLK ProQuest Central od 2005-03-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2008-06-01 do 2019-12-31
Health & Medicine (ProQuest) od 2005-03-01 do Před 1 rokem

In recent years, there is an increased interest in using scanning modes in proton therapy, due to the more conformal dose distributions, thanks to the spot-weighted dose delivery. The dose rate in each spot is however much higher than the dose rate when using passive irradiation modes, which could affect the cell response. The purpose of this work was to investigate how the relative biological effectiveness changes along the spread-out Bragg peak created by protons delivered by the pencil beam scanning mode. Cell survival and micronuclei formation were investigated in four positions along the spread-out Bragg peak for various doses. Monte Carlo simulations were used to estimate the dose-averaged linear energy transfer values in the irradiation positions. The cell survival was found to decrease the deeper the sample was placed in the spread-out Bragg peak, which corresponds to the higher linear energy transfer values found using Monte Carlo simulations. The micronuclei frequencies indicate more complex cell injuries at that distal position compared to the proximal part of the spread-out Bragg peak. The relative biological effectiveness determined in this study varies significantly and systematically from 1.1, which is recommended value by the International Commission on Radiation Units, in all the studied positions. In the distal position of spread-out Bragg peak the relative biological effectiveness values were found to be 2.05 ± 0.44, 1.85 ± 0.42, 1.53 ± 0.38 for survival levels 90, 50 and 10%, respectively.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18010737
003      
CZ-PrNML
005      
20180426095436.0
007      
ta
008      
180404s2017 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s13246-017-0540-8 $2 doi
035    __
$a (PubMed)28321635
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Michaelidesová, Anna $u Nuclear Physics Institute of the Czech Academy of Sciences, Řež 130, 25068, Řež, Czech Republic. anna.michaelidesova@odz.ujf.cas.cz. Proton Therapy Center Czech, Budínova 2437/1a, 18000, Prague, Czech Republic. anna.michaelidesova@odz.ujf.cas.cz. Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University, Břehová 7, 11519, Prague, Czech Republic. anna.michaelidesova@odz.ujf.cas.cz.
245    10
$a Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode / $c A. Michaelidesová, J. Vachelová, M. Puchalska, KP. Brabcová, V. Vondráček, L. Sihver, M. Davídková,
520    9_
$a In recent years, there is an increased interest in using scanning modes in proton therapy, due to the more conformal dose distributions, thanks to the spot-weighted dose delivery. The dose rate in each spot is however much higher than the dose rate when using passive irradiation modes, which could affect the cell response. The purpose of this work was to investigate how the relative biological effectiveness changes along the spread-out Bragg peak created by protons delivered by the pencil beam scanning mode. Cell survival and micronuclei formation were investigated in four positions along the spread-out Bragg peak for various doses. Monte Carlo simulations were used to estimate the dose-averaged linear energy transfer values in the irradiation positions. The cell survival was found to decrease the deeper the sample was placed in the spread-out Bragg peak, which corresponds to the higher linear energy transfer values found using Monte Carlo simulations. The micronuclei frequencies indicate more complex cell injuries at that distal position compared to the proximal part of the spread-out Bragg peak. The relative biological effectiveness determined in this study varies significantly and systematically from 1.1, which is recommended value by the International Commission on Radiation Units, in all the studied positions. In the distal position of spread-out Bragg peak the relative biological effectiveness values were found to be 2.05 ± 0.44, 1.85 ± 0.42, 1.53 ± 0.38 for survival levels 90, 50 and 10%, respectively.
650    _2
$a viabilita buněk $x účinky záření $7 D002470
650    _2
$a počítačová simulace $7 D003198
650    _2
$a vztah dávky záření a odpovědi $7 D004307
650    _2
$a lidé $7 D006801
650    _2
$a novorozenec $7 D007231
650    _2
$a lineární přenos energie $7 D018499
650    _2
$a mikrojaderné testy $7 D015162
650    12
$a protony $7 D011522
650    _2
$a radiometrie $7 D011874
650    12
$a relativní biologická účinnost $7 D012062
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vachelová, Jana $u Nuclear Physics Institute of the Czech Academy of Sciences, Řež 130, 25068, Řež, Czech Republic.
700    1_
$a Puchalska, Monika $u Atominstitut, Technische Universität Wien, Stadionallee 2, 1020, Vienna, Austria.
700    1_
$a Brabcová, Kateřina Pachnerová $u Nuclear Physics Institute of the Czech Academy of Sciences, Řež 130, 25068, Řež, Czech Republic.
700    1_
$a Vondráček, Vladimír $u Proton Therapy Center Czech, Budínova 2437/1a, 18000, Prague, Czech Republic.
700    1_
$a Sihver, Lembit $u Atominstitut, Technische Universität Wien, Stadionallee 2, 1020, Vienna, Austria. EBG, MedAustron, Marie-Curie-Straße 5, 2700, Wiener Neustadt, Vienna, Austria.
700    1_
$a Davídková, Marie $u Nuclear Physics Institute of the Czech Academy of Sciences, Řež 130, 25068, Řež, Czech Republic. Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University, Břehová 7, 11519, Prague, Czech Republic.
773    0_
$w MED00172800 $t Australasian physical & engineering sciences in medicine $x 1879-5447 $g Roč. 40, č. 2 (2017), s. 359-368
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28321635 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180404 $b ABA008
991    __
$a 20180426095546 $b ABA008
999    __
$a ok $b bmc $g 1288222 $s 1007549
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 40 $c 2 $d 359-368 $e 20170320 $i 1879-5447 $m Australasian physical & engineering sciences in medicine $n Australas Phys Eng Sci Med $x MED00172800
LZP    __
$a Pubmed-20180404

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace