• Je něco špatně v tomto záznamu ?

Correlation of shear and dielectric ion viscosity of dental resins - Influence of composition, temperature and filler content

J. Steinhaus, B. Hausnerova, T. Haenel, D. Selig, F. Duvenbeck, B. Moeginger,

. 2016 ; 32 (7) : 899-907. [pub] 20160426

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc18017283

OBJECTIVE: Shear viscosity and ion viscosity of uncured visible light-curing (VLC) resins and resin based composites (RBC) are correlated with respect to the resin composition, temperature and filler content to check where Dielectric Analysis (DEA) investigations of VLC RBC generate similar results as viscosity measurements. METHODS: Mixtures of bisphenol A glycidyl methacrylate (Bis-GMA) and triethylene glycol dimethacrylate (TEGDMA) as well as the pure resins were investigated and compared with two commercial VLC dental resins and RBCs (VOCO, Arabesk Top and Grandio). Shear viscosity data was obtained using a Haake Mars III, Thermo Scientific. Ion viscosity measurements performed by a dielectric cure analyzer (DEA 231/1 Epsilon with Mini IDEX-Sensor, Netzsch-Gerätebau). RESULTS: Shear viscosity depends reciprocally on the mobility of molecules, whereas the ion viscosity also depends on the ion concentration as it is affected by both ion concentration and mixture viscosity. Except of pure TEGDMA, shear and ion viscosities depend on the resin composition qualitatively in a similar manner. Furthermore, shear and ion viscosities of the commercial VLC dental resins and composites exhibited the same temperature dependency regardless of filler content. Application of typical rheological models (Kitano and Quemada) revealed that ion viscosity measurements can be described with respect to filler contents of up to 30vol.%. SIGNIFICANCE: Rheological behavior of a VLC RBC can be characterized by DEA under the condition that the ion concentration is kept constant. Both methods address the same physical phenomenon - motion of molecules. The proposed relations allows for calculating the viscosity of any Bis-GMA-TEGDMA mixture on the base of the viscosities of the pure components. This study demonstrated the applicability of DEA investigations of VLC RBCs with respect to quality assurance purposes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18017283
003      
CZ-PrNML
005      
20180523094113.0
007      
ta
008      
180515s2016 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.dental.2016.03.015 $2 doi
035    __
$a (PubMed)27130611
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Steinhaus, Johannes $u University Institute, Centre of Polymer Systems, Tomas Bata University in Zlín, Zlín, Czech Republic; Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany.
245    10
$a Correlation of shear and dielectric ion viscosity of dental resins - Influence of composition, temperature and filler content / $c J. Steinhaus, B. Hausnerova, T. Haenel, D. Selig, F. Duvenbeck, B. Moeginger,
520    9_
$a OBJECTIVE: Shear viscosity and ion viscosity of uncured visible light-curing (VLC) resins and resin based composites (RBC) are correlated with respect to the resin composition, temperature and filler content to check where Dielectric Analysis (DEA) investigations of VLC RBC generate similar results as viscosity measurements. METHODS: Mixtures of bisphenol A glycidyl methacrylate (Bis-GMA) and triethylene glycol dimethacrylate (TEGDMA) as well as the pure resins were investigated and compared with two commercial VLC dental resins and RBCs (VOCO, Arabesk Top and Grandio). Shear viscosity data was obtained using a Haake Mars III, Thermo Scientific. Ion viscosity measurements performed by a dielectric cure analyzer (DEA 231/1 Epsilon with Mini IDEX-Sensor, Netzsch-Gerätebau). RESULTS: Shear viscosity depends reciprocally on the mobility of molecules, whereas the ion viscosity also depends on the ion concentration as it is affected by both ion concentration and mixture viscosity. Except of pure TEGDMA, shear and ion viscosities depend on the resin composition qualitatively in a similar manner. Furthermore, shear and ion viscosities of the commercial VLC dental resins and composites exhibited the same temperature dependency regardless of filler content. Application of typical rheological models (Kitano and Quemada) revealed that ion viscosity measurements can be described with respect to filler contents of up to 30vol.%. SIGNIFICANCE: Rheological behavior of a VLC RBC can be characterized by DEA under the condition that the ion concentration is kept constant. Both methods address the same physical phenomenon - motion of molecules. The proposed relations allows for calculating the viscosity of any Bis-GMA-TEGDMA mixture on the base of the viscosities of the pure components. This study demonstrated the applicability of DEA investigations of VLC RBCs with respect to quality assurance purposes.
650    _2
$a bisfenol A-glycidyl methakrylát $7 D017438
650    12
$a stomatologické polymerizační lampy $7 D055117
650    12
$a syntetické pryskyřice $7 D012117
650    12
$a teplota $7 D013696
650    _2
$a viskozita $7 D014783
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Hausnerova, Berenika $u University Institute, Centre of Polymer Systems, Tomas Bata University in Zlín, Zlín, Czech Republic; Faculty of Technology, Department of Production Engineering, Tomas Bata University in Zlin, Zlín, Czech Republic. Electronic address: hausnerova@ft.utb.cz.
700    1_
$a Haenel, Thomas $u University Institute, Centre of Polymer Systems, Tomas Bata University in Zlín, Zlín, Czech Republic; Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany.
700    1_
$a Selig, Daniela $u Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany.
700    1_
$a Duvenbeck, Fabian $u Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany.
700    1_
$a Moeginger, Bernhard $u Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany.
773    0_
$w MED00001334 $t Dental materials official publication of the Academy of Dental Materials $x 1879-0097 $g Roč. 32, č. 7 (2016), s. 899-907
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27130611 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180515 $b ABA008
991    __
$a 20180523094258 $b ABA008
999    __
$a ok $b bmc $g 1300907 $s 1014123
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 32 $c 7 $d 899-907 $e 20160426 $i 1879-0097 $m Dental materials $n Dent Mater $x MED00001334
LZP    __
$a Pubmed-20180515

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...