Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Biomechanical evaluation of human lumbar spine in spondylolisthesis

Kamil Joszko, Marek Gzik, Wojciech Wolański, Bożena Gzik-Zroska, Edyta Kawlewska

. 2018 ; 16 (1) : 51-58.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc18019072

One of the least known conditions of the lumbar spine in terms of biomechanics is spondylolisthesis which causes many serious consequences for the patient. This research aimed to perform a mechanical analysis of the origins of spondylolisthesis and its impact on the biomechanics of the lumbar section of the spine. Within the framework of this study, a physiologically model of the lumbar spine was created in the MADYMO software. In the next stage a slip of vertebra L4 was simulated by means of a controlled forward displacement of the vertebral body of vertebra L4. 10 variants of spondylolisthesis (W1–W10) of different degrees were subjected to a biomechanical evaluation. In maximum bending of the physiological spine at an angle of 27° the value of the shear force amounted to 1.9 kN, while for the spine affected by spondylolisthesis with slip grade W9 at the maximum bending of 34° the shear force amounted to 5.5 kN. It was observed that the lumbar spine with the simulated spondylolisthesis had greater mobility in comparison with the physiological spine, which was shown by maximum bending angles (physiological 27°, W9 34°).

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc18019072
003      
CZ-PrNML
005      
20180830100439.0
007      
ta
008      
180525s2018 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jab.2017.10.004 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Joszko, Kamil $u Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland
245    10
$a Biomechanical evaluation of human lumbar spine in spondylolisthesis / $c Kamil Joszko, Marek Gzik, Wojciech Wolański, Bożena Gzik-Zroska, Edyta Kawlewska
504    __
$a Literatura
520    9_
$a One of the least known conditions of the lumbar spine in terms of biomechanics is spondylolisthesis which causes many serious consequences for the patient. This research aimed to perform a mechanical analysis of the origins of spondylolisthesis and its impact on the biomechanics of the lumbar section of the spine. Within the framework of this study, a physiologically model of the lumbar spine was created in the MADYMO software. In the next stage a slip of vertebra L4 was simulated by means of a controlled forward displacement of the vertebral body of vertebra L4. 10 variants of spondylolisthesis (W1–W10) of different degrees were subjected to a biomechanical evaluation. In maximum bending of the physiological spine at an angle of 27° the value of the shear force amounted to 1.9 kN, while for the spine affected by spondylolisthesis with slip grade W9 at the maximum bending of 34° the shear force amounted to 5.5 kN. It was observed that the lumbar spine with the simulated spondylolisthesis had greater mobility in comparison with the physiological spine, which was shown by maximum bending angles (physiological 27°, W9 34°).
650    _2
$a spondylolistéza $x diagnostické zobrazování $x patologie $7 D013168
650    _2
$a bederní obratle $x anatomie a histologie $x patofyziologie $x patologie $7 D008159
650    _2
$a biomechanika $7 D001696
650    _2
$a počítačová simulace $7 D003198
650    _2
$a teoretické modely $7 D008962
700    1_
$a Gzik, Marek $u Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland
700    1_
$a Wolański, Wojciech $u Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland
700    1_
$a Gzik-Zroska, Bożena $u Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomaterials and Medical Devices Engineering, Zabrze, Poland
700    1_
$a Kawlewska, Edyta $u Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland
773    0_
$t Journal of applied biomedicine $x 1214-021X $g Roč. 16, č. 1 (2018), s. 51-58 $w MED00012667
856    41
$u https://jab.zsf.jcu.cz/pdfs/jab/2018/01/09.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 2301 $c 1249 $y 4 $z 0
990    __
$a 20180525144545 $b ABA008
991    __
$a 20180830100824 $b ABA008
999    __
$a ok $b bmc $g 1304263 $s 1015917
BAS    __
$a 3
BMC    __
$a 2018 $b 16 $c 1 $d 51-58 $i 1214-021X $m Journal of Applied Biomedicine $x MED00012667
LZP    __
$c NLK125 $d 20180830 $a NLK 2018-22/dk

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...