Je něco špatně v tomto záznamu ?
RADON CONCENTRATION TIME SERIES MODELING AND APPLICATION DISCUSSION
V. Stránský, L. Thinová,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
PubMed
29045758
DOI
10.1093/rpd/ncx207
Knihovny.cz E-zdroje
- MeSH
- analýza přerušované časové série MeSH
- jeskyně MeSH
- monitorování radiace metody MeSH
- prediktivní hodnota testů MeSH
- radioaktivní látky znečišťující půdu analýza MeSH
- radon analýza MeSH
- roční období MeSH
- zemětřesení * MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
In the year 2010 a continual radon measurement was established at Mladeč Caves in the Czech Republic using a continual radon monitor RADIM3A. In order to model radon time series in the years 2010-15, the Box-Jenkins Methodology, often used in econometrics, was applied. Because of the behavior of radon concentrations (RCs), a seasonal integrated, autoregressive moving averages model with exogenous variables (SARIMAX) has been chosen to model the measured time series. This model uses the time series seasonality, previously acquired values and delayed atmospheric parameters, to forecast RC. The developed model for RC time series is called regARIMA(5,1,3). Model residuals could be retrospectively compared with seismic evidence of local or global earthquakes, which occurred during the RCs measurement. This technique enables us to asses if continuously measured RC could serve an earthquake precursor.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18024553
- 003
- CZ-PrNML
- 005
- 20180710093820.0
- 007
- ta
- 008
- 180709s2017 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncx207 $2 doi
- 035 __
- $a (PubMed)29045758
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Stránský, V $u Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Brehová 7, Praha 11 519, Czech Republic.
- 245 10
- $a RADON CONCENTRATION TIME SERIES MODELING AND APPLICATION DISCUSSION / $c V. Stránský, L. Thinová,
- 520 9_
- $a In the year 2010 a continual radon measurement was established at Mladeč Caves in the Czech Republic using a continual radon monitor RADIM3A. In order to model radon time series in the years 2010-15, the Box-Jenkins Methodology, often used in econometrics, was applied. Because of the behavior of radon concentrations (RCs), a seasonal integrated, autoregressive moving averages model with exogenous variables (SARIMAX) has been chosen to model the measured time series. This model uses the time series seasonality, previously acquired values and delayed atmospheric parameters, to forecast RC. The developed model for RC time series is called regARIMA(5,1,3). Model residuals could be retrospectively compared with seismic evidence of local or global earthquakes, which occurred during the RCs measurement. This technique enables us to asses if continuously measured RC could serve an earthquake precursor.
- 650 _2
- $a jeskyně $7 D059552
- 650 _2
- $a Česká republika $7 D018153
- 650 12
- $a zemětřesení $7 D055866
- 650 _2
- $a analýza přerušované časové série $7 D065186
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 _2
- $a monitorování radiace $x metody $7 D011834
- 650 _2
- $a radon $x analýza $7 D011886
- 650 _2
- $a roční období $7 D012621
- 650 _2
- $a radioaktivní látky znečišťující půdu $x analýza $7 D012990
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Thinová, L $u Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Brehová 7, Praha 11 519, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 177, č. 1-2 (2017), s. 155-159
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29045758 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180709 $b ABA008
- 991 __
- $a 20180710094109 $b ABA008
- 999 __
- $a ok $b bmc $g 1316684 $s 1021474
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 177 $c 1-2 $d 155-159 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20180709