Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms
R. Martinek, R. Kahankova, H. Nazeran, J. Konecny, J. Jezewski, P. Janku, P. Bilik, J. Zidek, J. Nedoma, M. Fajkus,
Language English Country Switzerland
Document type Journal Article
NLK
Directory of Open Access Journals
from 2001
PubMed Central
from 2003
Europe PubMed Central
from 2003
ProQuest Central
from 2001-01-01
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2003-01-01
Health & Medicine (ProQuest)
from 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
28534810
DOI
10.3390/s17051154
Knihovny.cz E-resources
- MeSH
- Algorithms MeSH
- Electrodes MeSH
- Electrocardiography MeSH
- Humans MeSH
- Fetal Monitoring * MeSH
- Signal Processing, Computer-Assisted MeSH
- Pregnancy MeSH
- Check Tag
- Humans MeSH
- Pregnancy MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18024997
- 003
- CZ-PrNML
- 005
- 20180710095253.0
- 007
- ta
- 008
- 180709s2017 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s17051154 $2 doi
- 035 __
- $a (PubMed)28534810
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Martinek, Radek $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. radek.martinek@vsb.cz.
- 245 10
- $a Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms / $c R. Martinek, R. Kahankova, H. Nazeran, J. Konecny, J. Jezewski, P. Janku, P. Bilik, J. Zidek, J. Nedoma, M. Fajkus,
- 520 9_
- $a This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a elektrokardiografie $7 D004562
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 12
- $a monitorování plodu $7 D005323
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a těhotenství $7 D011247
- 650 _2
- $a počítačové zpracování signálu $7 D012815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kahankova, Radana $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. radana.kahankova@vsb.cz.
- 700 1_
- $a Nazeran, Homer $u Department of Electrical and Computer Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA. hnazeran@utep.edu.
- 700 1_
- $a Konecny, Jaromir $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jaromir.konecny@vsb.cz.
- 700 1_
- $a Jezewski, Janusz $u Institute of Medical Technology and Equipment ITAM, 118 Roosevelt Str., 41-800 Zabrze, Poland. jezewski@itam.zabrze.pl.
- 700 1_
- $a Janku, Petr $u Department of Obstetrics and Gynecology, Masaryk University and University Hospital Brno, Jihlavska 20, 625 00 Brno, Czech Republic. janku.petr@fnbrno.cz.
- 700 1_
- $a Bilik, Petr $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. petr.bilik@vsb.cz.
- 700 1_
- $a Zidek, Jan $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jan.zidek@vsb.cz.
- 700 1_
- $a Nedoma, Jan $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jan.nedoma@vsb.cz.
- 700 1_
- $a Fajkus, Marcel $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. marcel.fajkus@vsb.cz.
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 17, č. 5 (2017)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28534810 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180709 $b ABA008
- 991 __
- $a 20180710095543 $b ABA008
- 999 __
- $a ok $b bmc $g 1317128 $s 1021918
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 17 $c 5 $e 20170519 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- LZP __
- $a Pubmed-20180709