Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms

R. Martinek, R. Kahankova, H. Nazeran, J. Konecny, J. Jezewski, P. Janku, P. Bilik, J. Zidek, J. Nedoma, M. Fajkus,

. 2017 ; 17 (5) : . [pub] 20170519

Language English Country Switzerland

Document type Journal Article

This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18024997
003      
CZ-PrNML
005      
20180710095253.0
007      
ta
008      
180709s2017 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/s17051154 $2 doi
035    __
$a (PubMed)28534810
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Martinek, Radek $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. radek.martinek@vsb.cz.
245    10
$a Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms / $c R. Martinek, R. Kahankova, H. Nazeran, J. Konecny, J. Jezewski, P. Janku, P. Bilik, J. Zidek, J. Nedoma, M. Fajkus,
520    9_
$a This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.
650    _2
$a algoritmy $7 D000465
650    _2
$a elektrokardiografie $7 D004562
650    _2
$a elektrody $7 D004566
650    _2
$a ženské pohlaví $7 D005260
650    12
$a monitorování plodu $7 D005323
650    _2
$a lidé $7 D006801
650    _2
$a těhotenství $7 D011247
650    _2
$a počítačové zpracování signálu $7 D012815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kahankova, Radana $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. radana.kahankova@vsb.cz.
700    1_
$a Nazeran, Homer $u Department of Electrical and Computer Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA. hnazeran@utep.edu.
700    1_
$a Konecny, Jaromir $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jaromir.konecny@vsb.cz.
700    1_
$a Jezewski, Janusz $u Institute of Medical Technology and Equipment ITAM, 118 Roosevelt Str., 41-800 Zabrze, Poland. jezewski@itam.zabrze.pl.
700    1_
$a Janku, Petr $u Department of Obstetrics and Gynecology, Masaryk University and University Hospital Brno, Jihlavska 20, 625 00 Brno, Czech Republic. janku.petr@fnbrno.cz.
700    1_
$a Bilik, Petr $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. petr.bilik@vsb.cz.
700    1_
$a Zidek, Jan $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jan.zidek@vsb.cz.
700    1_
$a Nedoma, Jan $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. jan.nedoma@vsb.cz.
700    1_
$a Fajkus, Marcel $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic. marcel.fajkus@vsb.cz.
773    0_
$w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 17, č. 5 (2017)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28534810 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20180710095543 $b ABA008
999    __
$a ok $b bmc $g 1317128 $s 1021918
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 17 $c 5 $e 20170519 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
LZP    __
$a Pubmed-20180709

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...