-
Je něco špatně v tomto záznamu ?
A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring
M. Fajkus, J. Nedoma, R. Martinek, V. Vasinek, H. Nazeran, P. Siska,
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
28075341
DOI
10.3390/s17010111
Knihovny.cz E-zdroje
- MeSH
- dechová frekvence MeSH
- lidé MeSH
- monitorování fyziologických funkcí MeSH
- optická vlákna MeSH
- srdeční frekvence MeSH
- technologie optických vláken * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
In this article, we briefly describe the design, construction, and functional verification of a hybrid multichannel fiber-optic sensor system for basic vital sign monitoring. This sensor uses a novel non-invasive measurement probe based on the fiber Bragg grating (FBG). The probe is composed of two FBGs encapsulated inside a polydimethylsiloxane polymer (PDMS). The PDMS is non-reactive to human skin and resistant to electromagnetic waves, UV absorption, and radiation. We emphasize the construction of the probe to be specifically used for basic vital sign monitoring such as body temperature, respiratory rate and heart rate. The proposed sensor system can continuously process incoming signals from up to 128 individuals. We first present the overall design of this novel multichannel sensor and then elaborate on how it has the potential to simplify vital sign monitoring and consequently improve the comfort level of patients in long-term health care facilities, hospitals and clinics. The reference ECG signal was acquired with the use of standard gel electrodes fixed to the monitored person's chest using a real-time monitoring system for ECG signals with virtual instrumentation. The outcomes of these experiments have unambiguously proved the functionality of the sensor system and will be used to inform our future research in this fast developing and emerging field.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18025198
- 003
- CZ-PrNML
- 005
- 20180710095245.0
- 007
- ta
- 008
- 180709s2017 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s17010111 $2 doi
- 035 __
- $a (PubMed)28075341
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Fajkus, Marcel $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic. marcel.fajkus@vsb.cz.
- 245 12
- $a A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring / $c M. Fajkus, J. Nedoma, R. Martinek, V. Vasinek, H. Nazeran, P. Siska,
- 520 9_
- $a In this article, we briefly describe the design, construction, and functional verification of a hybrid multichannel fiber-optic sensor system for basic vital sign monitoring. This sensor uses a novel non-invasive measurement probe based on the fiber Bragg grating (FBG). The probe is composed of two FBGs encapsulated inside a polydimethylsiloxane polymer (PDMS). The PDMS is non-reactive to human skin and resistant to electromagnetic waves, UV absorption, and radiation. We emphasize the construction of the probe to be specifically used for basic vital sign monitoring such as body temperature, respiratory rate and heart rate. The proposed sensor system can continuously process incoming signals from up to 128 individuals. We first present the overall design of this novel multichannel sensor and then elaborate on how it has the potential to simplify vital sign monitoring and consequently improve the comfort level of patients in long-term health care facilities, hospitals and clinics. The reference ECG signal was acquired with the use of standard gel electrodes fixed to the monitored person's chest using a real-time monitoring system for ECG signals with virtual instrumentation. The outcomes of these experiments have unambiguously proved the functionality of the sensor system and will be used to inform our future research in this fast developing and emerging field.
- 650 12
- $a technologie optických vláken $7 D005336
- 650 _2
- $a srdeční frekvence $7 D006339
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a monitorování fyziologických funkcí $7 D008991
- 650 _2
- $a optická vlákna $7 D055100
- 650 _2
- $a dechová frekvence $7 D056152
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Nedoma, Jan $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic. jan.nedoma@vsb.cz.
- 700 1_
- $a Martinek, Radek $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic. radek.martinek@vsb.cz.
- 700 1_
- $a Vasinek, Vladimir $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic. vladimir.vasinek@vsb.cz.
- 700 1_
- $a Nazeran, Homer $u Department of Electrical and Computer Engineering, University of Texas El Paso, 500W University Ave, El Paso, TX 79968, USA. hnazeran@utep.edu.
- 700 1_
- $a Siska, Petr $u Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic. petr.siska@vsb.cz.
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 17, č. 1 (2017)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28075341 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180709 $b ABA008
- 991 __
- $a 20180710095535 $b ABA008
- 999 __
- $a ok $b bmc $g 1317329 $s 1022119
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 17 $c 1 $e 20170108 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- LZP __
- $a Pubmed-20180709