J. Dudak, J. Zemlicka, J. Karch, M. Patzelt, J. Mrzilkova, P. Zach, Z. Hermanova, J. Kvacek, F. Krejci,

. 2016 ; 6 (-) : 30385. [pub] 20160727

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc18025341

Using dedicated contrast agents high-quality X-ray imaging of soft tissue structures with isotropic micrometre resolution has become feasible. This technique is frequently titled as virtual histology as it allows production of slices of tissue without destroying the sample. The use of contrast agents is, however, often an irreversible time-consuming procedure and despite the non-destructive principle of X-ray imaging, the sample is usually no longer usable for other research methods. In this work we present the application of recently developed large-area photon counting detector for high resolution X-ray micro-radiography and micro-tomography of whole ex-vivo ethanol-preserved mouse organs. The photon counting detectors provide dark-current-free quantum-counting operation enabling acquisition of data with virtually unlimited contrast-to-noise ratio (CNR). Thanks to the very high CNR even ethanol-only preserved soft-tissue samples without addition of any contrast agent can be visualized in great detail. As ethanol preservation is one of the standard steps of tissue fixation for histology, the presented method can open a way for widespread use of micro-CT with all its advantages for routine 3D non-destructive soft-tissue visualisation.

000      
00000naa a2200000 a 4500
001      
bmc18025341
003      
CZ-PrNML
005      
20220607090229.0
007      
ta
008      
180709s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/srep30385 $2 doi
035    __
$a (PubMed)27461900
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Dudak, Jan $u Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague, Czech Republic. Faculty of Biomedical Engineering, Czech Technical University in Prague, Namesti Sitna 3105, 272 01 Kladno, Czech Republic.
245    10
$a High-contrast X-ray micro-radiography and micro-CT of ex-vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector / $c J. Dudak, J. Zemlicka, J. Karch, M. Patzelt, J. Mrzilkova, P. Zach, Z. Hermanova, J. Kvacek, F. Krejci,
520    9_
$a Using dedicated contrast agents high-quality X-ray imaging of soft tissue structures with isotropic micrometre resolution has become feasible. This technique is frequently titled as virtual histology as it allows production of slices of tissue without destroying the sample. The use of contrast agents is, however, often an irreversible time-consuming procedure and despite the non-destructive principle of X-ray imaging, the sample is usually no longer usable for other research methods. In this work we present the application of recently developed large-area photon counting detector for high resolution X-ray micro-radiography and micro-tomography of whole ex-vivo ethanol-preserved mouse organs. The photon counting detectors provide dark-current-free quantum-counting operation enabling acquisition of data with virtually unlimited contrast-to-noise ratio (CNR). Thanks to the very high CNR even ethanol-only preserved soft-tissue samples without addition of any contrast agent can be visualized in great detail. As ethanol preservation is one of the standard steps of tissue fixation for histology, the presented method can open a way for widespread use of micro-CT with all its advantages for routine 3D non-destructive soft-tissue visualisation.
650    _2
$a zvířata $7 D000818
650    _2
$a ethanol $x chemie $7 D000431
650    _2
$a srdce $x diagnostické zobrazování $7 D006321
650    _2
$a ledviny $x diagnostické zobrazování $7 D007668
650    _2
$a plíce $x diagnostické zobrazování $7 D008168
650    _2
$a myši $7 D051379
650    _2
$a myši inbrední C57BL $7 D008810
650    12
$a fotony $7 D017785
650    _2
$a rentgenová mikrotomografie $x přístrojové vybavení $x metody $7 D055114
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Zemlicka, Jan $u Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague, Czech Republic.
700    1_
$a Karch, Jakub $u Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague, Czech Republic. Faculty of Biomedical Engineering, Czech Technical University in Prague, Namesti Sitna 3105, 272 01 Kladno, Czech Republic. $7 xx0273614
700    1_
$a Patzelt, Matej $u Third Faculty of Medicine, Charles University in Prague, Ruska 87, 100 00 Prague, Czech Republic.
700    1_
$a Mrzilkova, Jana $u Third Faculty of Medicine, Charles University in Prague, Ruska 87, 100 00 Prague, Czech Republic.
700    1_
$a Zach, Petr $u Third Faculty of Medicine, Charles University in Prague, Ruska 87, 100 00 Prague, Czech Republic.
700    1_
$a Hermanova, Zuzana $u National Museum, Vaclavske namesti 68, 115 79 Prague, Czech Republic.
700    1_
$a Kvacek, Jiri $u National Museum, Vaclavske namesti 68, 115 79 Prague, Czech Republic.
700    1_
$a Krejci, Frantisek $u Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague, Czech Republic.
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 6, č. - (2016), s. 30385
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27461900 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20220607090226 $b ABA008
999    __
$a ok $b bmc $g 1317472 $s 1022262
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 6 $c - $d 30385 $e 20160727 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
LZP    __
$a Pubmed-20180709

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...