-
Je něco špatně v tomto záznamu ?
Comparison of small size fully porous particles and superficially porous particles of chiral anion-exchange type stationary phases in ultra-high performance liquid chromatography: effect of particle and pore size on chromatographic efficiency and kinetic performance
K. Schmitt, U. Woiwode, M. Kohout, T. Zhang, W. Lindner, M. Lämmerhofer,
Jazyk angličtina Země Nizozemsko
Typ dokumentu srovnávací studie, časopisecké články
- MeSH
- adsorpce MeSH
- anionty MeSH
- chromatografie iontoměničová metody MeSH
- chromatografie s reverzní fází MeSH
- kinetika MeSH
- molekulová hmotnost MeSH
- poréznost MeSH
- velikost částic * MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
Recent advancements in particle design are common in reversed-phase liquid chromatography (RPLC), but in chiral separations their use is still sporadic in commercially available chiral stationary phases (CSPs). Due to reported lower mass transfer resistance, they might be a promising opportunity to increase efficiency and reduce time of analysis since the relatively higher mass transfer resistance term of CSPs caused by slow adsorption-desorption kinetics is the most performance-limiting factor in enantioselective chromatography. This study was dedicated to the evaluation of new support materials for tert-butylcarbamoylquinine (tBuCQN) based CSP to provide highly efficient and fast enantioseparations. As the main focus of this study, the chiral selector tBuCQN was immobilized on sub-2 μm fully porous particles (FPPs) and 2.7 μm superficially porous particles (SPPs) and their column performance in enantioseparation was evaluated in comparison to 5 μm FPPs by van Deemter and Knox analyses as well as kinetic plots using racemic Fmoc-Phe. Both new particle types outperformed the 5 μm FPP benchmark in terms of speed and efficiency, with wider pore materials (160 or 200 Å) being advantageous (over 90 or 120 Å). Basically decisive for the performance gain was the 10-times smaller mass transfer resistance. Furthermore, 2.7 μm 160 Å SPPs outperformed their fully porous sub-2 μm 120 Å counterpart (HminR = 4.64 μm vs. HminR = 8.94 μm) due to various parameters affording reduced plate height h of 1.7. Caused by the inaccessible core, separations were about 2-times faster. Packing of 2.7 μm core-shell particles provided a very homogeneous column bed, and, owing to its higher permeability, the column backpressure was much lower. It enables packing of longer columns providing theoretically separation efficiencies of up to 106 plates per m (as indicated by kinetic plots) and versatile use without the necessity of UHPLC systems. Investigating the effect of particle size reduction (FPPs: 5 μm, 3 μm, 1.7 μm; SPPs: 2.7 μm, 2 μm) and wider pores (FPPs: 120 Å, 200 Å; SPPs: 90 Å, 160 Å), a significantly reduced mass transfer resistance was the driving force for performance gain. Individual contributions of peak dispersion were deconvoluted for 5 μm FPP CSP and confirmed that slow adsorption-desorption kinetics is the most significant contribution to peak broadening in this chromatographic system.
Chiral Technologies Europe 160 Boulevard Gonthier d'Andernach 67400 Illkirch Graffenstaden France
Department of Organic Chemistry University of Chemistry and Technology Prague Czech Republic
Institute of Analytical Chemistry University of Vienna Waehringerstrasse 38 1090 Vienna Austria
Lindner Consulting GmbH Ziegelofengasse 37 3400 Klosterneuburg Austria
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18032998
- 003
- CZ-PrNML
- 005
- 20181008122204.0
- 007
- ta
- 008
- 181008s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2018.07.056 $2 doi
- 035 __
- $a (PubMed)30041874
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Schmitt, Kristina $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
- 245 10
- $a Comparison of small size fully porous particles and superficially porous particles of chiral anion-exchange type stationary phases in ultra-high performance liquid chromatography: effect of particle and pore size on chromatographic efficiency and kinetic performance / $c K. Schmitt, U. Woiwode, M. Kohout, T. Zhang, W. Lindner, M. Lämmerhofer,
- 520 9_
- $a Recent advancements in particle design are common in reversed-phase liquid chromatography (RPLC), but in chiral separations their use is still sporadic in commercially available chiral stationary phases (CSPs). Due to reported lower mass transfer resistance, they might be a promising opportunity to increase efficiency and reduce time of analysis since the relatively higher mass transfer resistance term of CSPs caused by slow adsorption-desorption kinetics is the most performance-limiting factor in enantioselective chromatography. This study was dedicated to the evaluation of new support materials for tert-butylcarbamoylquinine (tBuCQN) based CSP to provide highly efficient and fast enantioseparations. As the main focus of this study, the chiral selector tBuCQN was immobilized on sub-2 μm fully porous particles (FPPs) and 2.7 μm superficially porous particles (SPPs) and their column performance in enantioseparation was evaluated in comparison to 5 μm FPPs by van Deemter and Knox analyses as well as kinetic plots using racemic Fmoc-Phe. Both new particle types outperformed the 5 μm FPP benchmark in terms of speed and efficiency, with wider pore materials (160 or 200 Å) being advantageous (over 90 or 120 Å). Basically decisive for the performance gain was the 10-times smaller mass transfer resistance. Furthermore, 2.7 μm 160 Å SPPs outperformed their fully porous sub-2 μm 120 Å counterpart (HminR = 4.64 μm vs. HminR = 8.94 μm) due to various parameters affording reduced plate height h of 1.7. Caused by the inaccessible core, separations were about 2-times faster. Packing of 2.7 μm core-shell particles provided a very homogeneous column bed, and, owing to its higher permeability, the column backpressure was much lower. It enables packing of longer columns providing theoretically separation efficiencies of up to 106 plates per m (as indicated by kinetic plots) and versatile use without the necessity of UHPLC systems. Investigating the effect of particle size reduction (FPPs: 5 μm, 3 μm, 1.7 μm; SPPs: 2.7 μm, 2 μm) and wider pores (FPPs: 120 Å, 200 Å; SPPs: 90 Å, 160 Å), a significantly reduced mass transfer resistance was the driving force for performance gain. Individual contributions of peak dispersion were deconvoluted for 5 μm FPP CSP and confirmed that slow adsorption-desorption kinetics is the most significant contribution to peak broadening in this chromatographic system.
- 650 _2
- $a adsorpce $7 D000327
- 650 _2
- $a anionty $7 D000838
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a chromatografie iontoměničová $x metody $7 D002852
- 650 _2
- $a chromatografie s reverzní fází $7 D056148
- 650 _2
- $a kinetika $7 D007700
- 650 _2
- $a molekulová hmotnost $7 D008970
- 650 12
- $a velikost částic $7 D010316
- 650 _2
- $a poréznost $7 D016062
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Woiwode, Ulrich $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
- 700 1_
- $a Kohout, Michal $u Department of Organic Chemistry, University of Chemistry and Technology, Prague, Czech Republic.
- 700 1_
- $a Zhang, Tong $u Chiral Technologies Europe, 160 Boulevard Gonthier d'Andernach, 67400 Illkirch-Graffenstaden, France.
- 700 1_
- $a Lindner, Wolfgang $u Lindner Consulting GmbH, Ziegelofengasse 37, 3400 Klosterneuburg, Austria; Institute of Analytical Chemistry, University of Vienna, Waehringerstrasse 38, 1090 Vienna, Austria.
- 700 1_
- $a Lämmerhofer, Michael $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany. Electronic address: michael.laemmerhofer@uni-tuebingen.de.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1569, č. - (2018), s. 149-159
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30041874 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20181008122651 $b ABA008
- 999 __
- $a ok $b bmc $g 1339337 $s 1029992
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 1569 $c - $d 149-159 $e 20180718 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20181008