-
Je něco špatně v tomto záznamu ?
Comparison of two low flow interfaces for measurement of mobilities and stability constants by affinity capillary electrophoresis-mass spectrometry
R. Konášová, D. Koval, JJ. Dytrtová, V. Kašička,
Jazyk angličtina Země Nizozemsko
Typ dokumentu srovnávací studie, časopisecké články
- MeSH
- crown ethery chemie MeSH
- elektřina MeSH
- elektroforéza kapilární metody MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací metody MeSH
- kinetika MeSH
- poréznost MeSH
- reologie * MeSH
- rozpouštědla MeSH
- voda MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
Affinity capillary electrophoresis (ACE) is typically used for the determination of stability constant, Kst, of weak to moderately strong complexes. Sensitive detection such as mass spectrometry (MS) is required for extension of ACE methodology for estimation of Kst of stronger complexes. Consequently, an efficient interface for hyphenation of CE with MS detection is necessary. For evaluation of interfaces for electrospray ionization mass spectrometric (ESI/MS) detection in ACE conditions, potassium-crown ether complexation was used as model system. The effective mobilities of the crown ether ligands and the Kst of their potassium complexes were measured/determined by ACE-ESI/MS using two lab-made interfaces: (i) a sheathless porous tip CE-ESI/MS interface and (ii) a nano-sheath liquid flow CE-ESI/MS interface, and, in turn, compared with those obtained by ACE with UV spectrophotometric detection. Apparent stability constant of potassium-crown ether complexes in 60/40 (v/v) methanol/water mixed solvent, pH* 5.5, was about 1300 L/mol for dibenzo-18-crown-6, 1600 L/mol for benzo-18-crown-6 and 5200 L/mol for 18-crown-6 ligands, respectively. It was observed that electrophoretic mobilities from CE-MS experiments differ from reference values determined by UV detection by ∼7% depending on the CE-MS interface used. Good agreement of CE-MS and CE-UV data was achieved for nano-sheath liquid flow interface, in which the spray potential and the CE separation potential can be effectively decoupled. As for sheathless porous tip interface, a correction procedure involving a mobility marker has been proposed. It provides typically only ca. 1% difference of effective mobilities and Kst values obtained from CE-MS data as compared to those received by the reference ACE-UV method.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18033000
- 003
- CZ-PrNML
- 005
- 20181008122204.0
- 007
- ta
- 008
- 181008s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2018.07.014 $2 doi
- 035 __
- $a (PubMed)30033170
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Konášová, Renáta $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 2, 166 10 Prague 6, Czech Republic; Faculty of Science, Charles University, Department of Analytical Chemistry, Albertov 6, 128 43 Prague 2, Czech Republic.
- 245 10
- $a Comparison of two low flow interfaces for measurement of mobilities and stability constants by affinity capillary electrophoresis-mass spectrometry / $c R. Konášová, D. Koval, JJ. Dytrtová, V. Kašička,
- 520 9_
- $a Affinity capillary electrophoresis (ACE) is typically used for the determination of stability constant, Kst, of weak to moderately strong complexes. Sensitive detection such as mass spectrometry (MS) is required for extension of ACE methodology for estimation of Kst of stronger complexes. Consequently, an efficient interface for hyphenation of CE with MS detection is necessary. For evaluation of interfaces for electrospray ionization mass spectrometric (ESI/MS) detection in ACE conditions, potassium-crown ether complexation was used as model system. The effective mobilities of the crown ether ligands and the Kst of their potassium complexes were measured/determined by ACE-ESI/MS using two lab-made interfaces: (i) a sheathless porous tip CE-ESI/MS interface and (ii) a nano-sheath liquid flow CE-ESI/MS interface, and, in turn, compared with those obtained by ACE with UV spectrophotometric detection. Apparent stability constant of potassium-crown ether complexes in 60/40 (v/v) methanol/water mixed solvent, pH* 5.5, was about 1300 L/mol for dibenzo-18-crown-6, 1600 L/mol for benzo-18-crown-6 and 5200 L/mol for 18-crown-6 ligands, respectively. It was observed that electrophoretic mobilities from CE-MS experiments differ from reference values determined by UV detection by ∼7% depending on the CE-MS interface used. Good agreement of CE-MS and CE-UV data was achieved for nano-sheath liquid flow interface, in which the spray potential and the CE separation potential can be effectively decoupled. As for sheathless porous tip interface, a correction procedure involving a mobility marker has been proposed. It provides typically only ca. 1% difference of effective mobilities and Kst values obtained from CE-MS data as compared to those received by the reference ACE-UV method.
- 650 _2
- $a crown ethery $x chemie $7 D043844
- 650 _2
- $a elektřina $7 D004560
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a kinetika $7 D007700
- 650 _2
- $a poréznost $7 D016062
- 650 12
- $a reologie $7 D012212
- 650 _2
- $a rozpouštědla $7 D012997
- 650 _2
- $a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Koval, Dušan $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 2, 166 10 Prague 6, Czech Republic. Electronic address: koval@uochb.cas.cz.
- 700 1_
- $a Dytrtová, Jana Jaklová $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 2, 166 10 Prague 6, Czech Republic; Faculty of Physical Education and Sport, Charles University, Jose Martího 31, 162 52 Prague 6, Czech Republic.
- 700 1_
- $a Kašička, Václav $u Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 2, 166 10 Prague 6, Czech Republic. Electronic address: kasicka@uochb.cas.cz.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1568, č. - (2018), s. 197-204
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30033170 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20181008122651 $b ABA008
- 999 __
- $a ok $b bmc $g 1339339 $s 1029994
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 1568 $c - $d 197-204 $e 20180720 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20181008