• Je něco špatně v tomto záznamu ?

Quantification of volatile compounds released by roasted coffee by selected ion flow tube mass spectrometry

K. Dryahina, D. Smith, P. Španěl,

. 2018 ; 32 (9) : 739-750.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18033279

RATIONALE: The major objective of this exploratory study was to implement selected ion flow tube mass spectrometry, SIFT-MS, as a method for the on-line quantification of the volatile organic compounds, VOCs, in the headspace of the ground roasted coffee. METHODS: The optimal precursor ions and characteristic analyte ions were selected for real-time SIFT-MS quantification of those VOCs that are the most abundant in the headspace or known to contribute to aroma. NO+ reagent ion reactions were exploited for most of the VOC analyses. VOC identifications were confirmed using gas chromatography/mass spectrometry, GC/MS, coupled with solid-phase microextraction, SPME. RESULTS: Thirty-one VOCs were quantified, including several alcohols, aldehydes, ketones, carboxylic acids, esters and some heterocyclic compounds. Variations in the concentrations of each VOC in the seven regional coffees were typically less than a factor of 2, yet concentrations patterns characteristic of the different regional coffees were revealed by heat map and principal component analyses. The coefficient of variation in the concentrations across the seven coffees was typically below 24% except for furfural, furan, methylfuran and guaiacol. CONCLUSIONS: The SIFT-MS analytical method can be used to quantify in real time the most important odoriferous VOCs in ground coffee headspace to sufficient precision to reveal some differences in concentration patterns for coffee produced in different countries.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18033279
003      
CZ-PrNML
005      
20191118082038.0
007      
ta
008      
181008s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/rcm.8095 $2 doi
035    __
$a (PubMed)29486530
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Nejtek, Tomáš $7 xx0241955 $u J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, v.v.i., Dolejškova 3, 182 23, Prague 8, Czech Republic.
245    10
$a Quantification of volatile compounds released by roasted coffee by selected ion flow tube mass spectrometry / $c K. Dryahina, D. Smith, P. Španěl,
520    9_
$a RATIONALE: The major objective of this exploratory study was to implement selected ion flow tube mass spectrometry, SIFT-MS, as a method for the on-line quantification of the volatile organic compounds, VOCs, in the headspace of the ground roasted coffee. METHODS: The optimal precursor ions and characteristic analyte ions were selected for real-time SIFT-MS quantification of those VOCs that are the most abundant in the headspace or known to contribute to aroma. NO+ reagent ion reactions were exploited for most of the VOC analyses. VOC identifications were confirmed using gas chromatography/mass spectrometry, GC/MS, coupled with solid-phase microextraction, SPME. RESULTS: Thirty-one VOCs were quantified, including several alcohols, aldehydes, ketones, carboxylic acids, esters and some heterocyclic compounds. Variations in the concentrations of each VOC in the seven regional coffees were typically less than a factor of 2, yet concentrations patterns characteristic of the different regional coffees were revealed by heat map and principal component analyses. The coefficient of variation in the concentrations across the seven coffees was typically below 24% except for furfural, furan, methylfuran and guaiacol. CONCLUSIONS: The SIFT-MS analytical method can be used to quantify in real time the most important odoriferous VOCs in ground coffee headspace to sufficient precision to reveal some differences in concentration patterns for coffee produced in different countries.
650    _2
$a alkoholy $x analýza $7 D000438
650    _2
$a aldehydy $x analýza $7 D000447
650    _2
$a Coffea $x chemie $7 D040503
650    _2
$a káva $x chemie $7 D003069
650    _2
$a analýza potravin $x metody $7 D005504
650    _2
$a manipulace s potravinami $7 D005511
650    _2
$a plynová chromatografie s hmotnostně spektrometrickou detekcí $x metody $7 D008401
650    _2
$a ketony $x analýza $7 D007659
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a analýza hlavních komponent $7 D025341
650    _2
$a mikroextrakce na pevné fázi $x metody $7 D052617
650    _2
$a těkavé organické sloučeniny $x analýza $x chemie $7 D055549
655    _2
$a časopisecké články $7 D016428
700    1_
$a Smith, David $u Trans Spectra Limited, 9 The Elms, Newcastle-under-Lyme, ST5 8RP, UK.
700    1_
$a Španěl, Patrik $u J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, v.v.i., Dolejškova 3, 182 23, Prague 8, Czech Republic.
773    0_
$w MED00004050 $t Rapid communications in mass spectrometry RCM $x 1097-0231 $g Roč. 32, č. 9 (2018), s. 739-750
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29486530 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20191118082319 $b ABA008
999    __
$a ok $b bmc $g 1340083 $s 1030273
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 32 $c 9 $d 739-750 $i 1097-0231 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a Pubmed-20181008

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...