Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition
M. Beňovská, O. Wiewiorka, J. Pinkavová,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu hodnotící studie, časopisecké články
- MeSH
- analýza moči přístrojové vybavení MeSH
- lidé MeSH
- referenční hodnoty MeSH
- směrnice jako téma MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R2 = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18033404
- 003
- CZ-PrNML
- 005
- 20210608140900.0
- 007
- ta
- 008
- 181008s2018 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1080/00365513.2017.1423108 $2 doi
- 035 __
- $a (PubMed)29310458
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Beňovská, Miroslava $u a Department of Clinical Biochemistry , University Hospital Brno , Brno , Czech Republic. b Department of Laboratory Methods, Faculty of Medicine , Masaryk University , Brno , Czech Republic.
- 245 10
- $a Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition / $c M. Beňovská, O. Wiewiorka, J. Pinkavová,
- 520 9_
- $a This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R2 = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.
- 650 _2
- $a směrnice jako téma $7 D017408
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a referenční hodnoty $7 D012016
- 650 _2
- $a analýza moči $x přístrojové vybavení $7 D016482
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Wiewiorka, Ondřej $u a Department of Clinical Biochemistry , University Hospital Brno , Brno , Czech Republic. b Department of Laboratory Methods, Faculty of Medicine , Masaryk University , Brno , Czech Republic. c Department of Biochemistry, Faculty of Medicine , Masaryk University , Brno , Czech Republic. $7 xx0260774
- 700 1_
- $a Pinkavová, Jana $u a Department of Clinical Biochemistry , University Hospital Brno , Brno , Czech Republic.
- 773 0_
- $w MED00010597 $t Scandinavian journal of clinical and laboratory investigation $x 1502-7686 $g Roč. 78, č. 1-2 (2018), s. 143-148
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29310458 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20210608140858 $b ABA008
- 999 __
- $a ok $b bmc $g 1340138 $s 1030398
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 78 $c 1-2 $d 143-148 $e 20180108 $i 1502-7686 $m Scandinavian journal of clinical & laboratory investigation $n Scand J Clin Lab Invest $x MED00010597
- LZP __
- $a Pubmed-20181008