• Je něco špatně v tomto záznamu ?

True lab-in-a-syringe technology for bioassays

L. Hárendarčíková, D. Baron, A. Šebestová, J. Rozsypal, J. Petr,

. 2017 ; 174 (-) : 285-288. [pub] 20170607

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18033811

In our work, we introduced a novel concept of the lab-in-a-syringe tests. We solved the problem of detection in already published LIS tests by putting all the reaction and detection pads directly into the syringe barrel. We also used more layers to make the results visible for users. Two detection layouts: (i) with using rounded pads-based detection, and (ii) with using rectangular detection pads, were studied. As the proof of concept, we studied the determination of Ni(II) using dimethylglyoxime as the reagent and blocking of the interference of Fe(II). The calibrations for Ni(II) at the optimal conditions has excellent R2 of 0.998 with production costs of 0.2 USD per one test.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18033811
003      
CZ-PrNML
005      
20181008122220.0
007      
ta
008      
181008s2017 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2017.06.017 $2 doi
035    __
$a (PubMed)28738580
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Hárendarčíková, Lenka $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacký University in Olomouc, 17. listopadu 12, 77146 Olomouc, Czech Republic.
245    10
$a True lab-in-a-syringe technology for bioassays / $c L. Hárendarčíková, D. Baron, A. Šebestová, J. Rozsypal, J. Petr,
520    9_
$a In our work, we introduced a novel concept of the lab-in-a-syringe tests. We solved the problem of detection in already published LIS tests by putting all the reaction and detection pads directly into the syringe barrel. We also used more layers to make the results visible for users. Two detection layouts: (i) with using rounded pads-based detection, and (ii) with using rectangular detection pads, were studied. As the proof of concept, we studied the determination of Ni(II) using dimethylglyoxime as the reagent and blocking of the interference of Fe(II). The calibrations for Ni(II) at the optimal conditions has excellent R2 of 0.998 with production costs of 0.2 USD per one test.
650    _2
$a biotest $x přístrojové vybavení $7 D001681
650    _2
$a design vybavení $7 D004867
650    12
$a injekční stříkačky $7 D013594
655    _2
$a časopisecké články $7 D016428
700    1_
$a Baron, Daniel $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacký University in Olomouc, 17. listopadu 12, 77146 Olomouc, Czech Republic.
700    1_
$a Šebestová, Andrea $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacký University in Olomouc, 17. listopadu 12, 77146 Olomouc, Czech Republic.
700    1_
$a Rozsypal, Jan $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacký University in Olomouc, 17. listopadu 12, 77146 Olomouc, Czech Republic.
700    1_
$a Petr, Jan $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacký University in Olomouc, 17. listopadu 12, 77146 Olomouc, Czech Republic. Electronic address: secjpetr@gmail.com.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 174, č. - (2017), s. 285-288
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28738580 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20181008122707 $b ABA008
999    __
$a ok $b bmc $g 1339601 $s 1030805
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 174 $c - $d 285-288 $e 20170607 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20181008

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace