Inter-comparison of quantitative imaging of lutetium-177 (177Lu) in European hospitals

J. Wevrett, A. Fenwick, J. Scuffham, L. Johansson, J. Gear, S. Schlögl, M. Segbers, K. Sjögreen-Gleisner, P. Solný, M. Lassmann, J. Tipping, A. Nisbet,

. 2018 ; 5 (1) : 17. [pub] 20180802

Language English Country Germany

Document type Journal Article

BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (177Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources-they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18034332
003      
CZ-PrNML
005      
20181026114447.0
007      
ta
008      
181008s2018 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s40658-018-0213-z $2 doi
035    __
$a (PubMed)30069805
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Wevrett, Jill $u University of Surrey, Guildford, UK. Jill.Wevrett@nhs.net. National Physical Laboratory, Teddington, UK. Jill.Wevrett@nhs.net. Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK. Jill.Wevrett@nhs.net.
245    10
$a Inter-comparison of quantitative imaging of lutetium-177 (177Lu) in European hospitals / $c J. Wevrett, A. Fenwick, J. Scuffham, L. Johansson, J. Gear, S. Schlögl, M. Segbers, K. Sjögreen-Gleisner, P. Solný, M. Lassmann, J. Tipping, A. Nisbet,
520    9_
$a BACKGROUND: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (177Lu) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources-they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. RESULTS: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. CONCLUSIONS: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Fenwick, Andrew $u National Physical Laboratory, Teddington, UK.
700    1_
$a Scuffham, James $u University of Surrey, Guildford, UK. Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK.
700    1_
$a Johansson, Lena $u National Physical Laboratory, Teddington, UK.
700    1_
$a Gear, Jonathan $u The Royal Marsden NHS Foundation Trust, Sutton, UK.
700    1_
$a Schlögl, Susanne $u University Hospital of Wϋrzburg, Wϋrzburg, Germany.
700    1_
$a Segbers, Marcel $u Erasmus University Medical Centre, Rotterdam, Netherlands.
700    1_
$a Sjögreen-Gleisner, Katarina $u Department of Medical Radiation Physics, Clinical Sciences Lund, Lund University, Lund, Sweden.
700    1_
$a Solný, Pavel $u Motol University Hospital, Prague, Czech Republic.
700    1_
$a Lassmann, Michael $u University Hospital of Wϋrzburg, Wϋrzburg, Germany.
700    1_
$a Tipping, Jill $u The Christie NHS Foundation Trust, Manchester, UK.
700    1_
$a Nisbet, Andrew $u University of Surrey, Guildford, UK. Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK.
773    0_
$w MED00194294 $t EJNMMI physics $x 2197-7364 $g Roč. 5, č. 1 (2018), s. 17
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30069805 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20181026114958 $b ABA008
999    __
$a ind $b bmc $g 1340515 $s 1031326
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 5 $c 1 $d 17 $e 20180802 $i 2197-7364 $m EJNMMI physics $n EJNMMI Phys $x MED00194294
LZP    __
$a Pubmed-20181008

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...