Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Cableless measurement of hand griping patterns and heart rate with flexible pressure sensor sheet

Tianyi Wang, Hieyong Jeong, An Guo, Takafumi Ohno, Na Li, Yuko Ohno

. 2018 ; 14 (4) : 4-11.

Language English Country Czech Republic

Document type Evaluation Study

Background: Driver's behaviours such as poor steering patterns and drowsy driving at the steering wheel have been recognized as main causes of traffic accidents. However, little researches focused on how drivers hold the steering wheel and previous studies have not addressed cableless approach to measure heart rate from hand griping. In this paper, we proposed a basic study on measuring hand griping patterns and heart rate simultaneously through hand griping using flexible pressure sensor sheet. Methods: Six volunteers were asked to steer a cylinder bar with six different hand griping patterns and steer still for 60 seconds for five times, hand griping pressure was measured using pressure sensor sheet, hand griping patterns were identified by hand griping pressure distribution, heart rate was calculated from hand griping pressure filtered by band pass filter (BPF) and the results were crosschecked by gold standard measurement system. Results: According to experiment results, proposed flexible pressure sensor sheet can clearly perform hand griping patterns, heart rate detection showed high accuracy (94%) and good agreement compared with gold standard measurement system. Conclusion: It was concluded that proposed method showed high potential application for measuring hand griping patterns and heart rate with cableless measurement.

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc18035728
003      
CZ-PrNML
005      
20200731093621.0
007      
cr|cn|
008      
181024s2018 xr a fs 000 0|eng||
009      
eAR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Wang,Tianyi $u Department of Robotics & Design for Innovative Healthcare, Graduate School of Medicine, Osaka University, Osaka, Japan
245    10
$a Cableless measurement of hand griping patterns and heart rate with flexible pressure sensor sheet / $c Tianyi Wang, Hieyong Jeong, An Guo, Takafumi Ohno, Na Li, Yuko Ohno
504    __
$a Literatura
520    9_
$a Background: Driver's behaviours such as poor steering patterns and drowsy driving at the steering wheel have been recognized as main causes of traffic accidents. However, little researches focused on how drivers hold the steering wheel and previous studies have not addressed cableless approach to measure heart rate from hand griping. In this paper, we proposed a basic study on measuring hand griping patterns and heart rate simultaneously through hand griping using flexible pressure sensor sheet. Methods: Six volunteers were asked to steer a cylinder bar with six different hand griping patterns and steer still for 60 seconds for five times, hand griping pressure was measured using pressure sensor sheet, hand griping patterns were identified by hand griping pressure distribution, heart rate was calculated from hand griping pressure filtered by band pass filter (BPF) and the results were crosschecked by gold standard measurement system. Results: According to experiment results, proposed flexible pressure sensor sheet can clearly perform hand griping patterns, heart rate detection showed high accuracy (94%) and good agreement compared with gold standard measurement system. Conclusion: It was concluded that proposed method showed high potential application for measuring hand griping patterns and heart rate with cableless measurement.
650    _2
$a lidé $7 D006801
650    12
$a síla ruky $7 D018737
650    12
$a dopravní nehody $7 D000063
650    _2
$a doprava $7 D014186
650    _2
$a hodnocení rizik $7 D018570
650    _2
$a srdeční frekvence $7 D006339
655    _2
$a hodnotící studie $7 D023362
700    1_
$a Jeong, Hieyong $u Department of Robotics & Design for Innovative Healthcare, Graduate School of Medicine, Osaka University, Osaka, Japan
700    1_
$a Guo, An $u Department of Robotics & Design for Innovative Healthcare, Graduate School of Medicine, Osaka University, Osaka, Japan
700    1_
$a Ohno, Takafumi $u Department of Robotics & Design for Innovative Healthcare, Graduate School of Medicine, Osaka University, Osaka, Japan
700    1_
$a Li, Na $u Department of Robotics & Design for Innovative Healthcare, Graduate School of Medicine, Osaka University, Osaka, Japan
700    1_
$a Ohno, Yuko $u Department of Mathematical Health Science, Graduate School of Medicine, Osaka University, Osaka, Japan
773    0_
$t European journal for biomedical informatics $x 1801-5603 $g Roč. 14, č. 4 (2018), s. 4-11 $w MED00173462
856    41
$u https://www.ejbi.org/scholarly-articles/cableless-measurement-of-hand-griping-patterns-and-heart-rate-with-flexible-pressure-sensor-sheet.pdf $y plný text volně přístupný
910    __
$a ABA008 $b online $y p $z 0
990    __
$a 20181024061056 $b ABA008
991    __
$a 20200731093620 $b ABA008
999    __
$a ok $b bmc $g 1345408 $s 1032740
BAS    __
$a 3 $a 4
BMC    __
$a 2018 $b 14 $c 4 $d 4-11 $i 1801-5603 $m European Journal for Biomedical Informatics $n Eur. J. Biomed. Inform. (Praha) $x MED00173462
LZP    __
$c NLK197 $d 20200731 $a NLK 2018-40/vt

Find record

Citation metrics

Loading data ...

Archiving options