-
Je něco špatně v tomto záznamu ?
Risk factors for failure of continuous positive airway pressure treatment in patients with ostructive sleep apnoea
D. Slouka, M. Honnerova, P. Hosek, A. Matas, K. Slama, J. Landsmanova, R. Kucera
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články, pozorovací studie
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
29358787
DOI
10.5507/bp.2017.056
Knihovny.cz E-zdroje
- MeSH
- index tělesné hmotnosti MeSH
- lidé středního věku MeSH
- lidé MeSH
- neúspěšná terapie MeSH
- obezita komplikace MeSH
- obstrukční spánková apnoe komplikace terapie MeSH
- plocha pod křivkou MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- ROC křivka MeSH
- trvalý přetlak v dýchacích cestách * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
BACKGROUND AND AIMS: Obstructive sleep apnoea is a potentially serious sleep disorder associated with the risk of cardiovascular disease. It is treated with continuous airway pressure (CPAP) but this is not always successful. Unsuccessful cases should be treated by bilevel positive airway pressure (BiPAP). The aim of this study was to determine whether common respiratory parameters and/or body mass index (BMI) can be used to predict the probability CPAP failure and hence start such patients on BiPAP from the outset. METHODS: A sample of patients treated by CPAP for OSAS was evaluated a retrospective cohort study. The data measured in sleep monitoring of the successfully treated group and of the group where CPAP had failed were compared. Subsequently, the predictive abilities of BMI, Apnoea Index (AI), Apnoea-Hypopnea Index (AHI), percentage of sleep time in less than 90% oxygen saturation (T90), average oxygen saturation over the duration of sleep (SaO2) and average desaturation per hour of sleep (ODI) were assessed with respect to CPAP failure, both individually and in combination. RESULTS: A sample of 479 patients was included in the study. All of the recorded variables except AI were significantly associated with failure of CPAP and their ability to predict the failure ranged from poor to moderate. Since there was significant correlation among all the variables measured a two-variable prediction model combining T90 and BMI produced no significant improvement in the quality of CPAP failure prediction. CONCLUSIONS: BMI was a significant predictor of CPAP failure although it was slightly less predictive than T90. The set of monitored variables included in our study does not allow for CPAP failure to be predicted with clinically relevant reliability.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18038663
- 003
- CZ-PrNML
- 005
- 20190603144244.0
- 007
- ta
- 008
- 181123s2018 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2017.056 $2 doi
- 035 __
- $a (PubMed)29358787
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Slouka, David $u Department of Otorhinolaryngology, Faculty of Medicine in Plzen, Charles University in Prague, E Pilsen, Czech Republic $7 xx0139295
- 245 10
- $a Risk factors for failure of continuous positive airway pressure treatment in patients with ostructive sleep apnoea / $c D. Slouka, M. Honnerova, P. Hosek, A. Matas, K. Slama, J. Landsmanova, R. Kucera
- 520 9_
- $a BACKGROUND AND AIMS: Obstructive sleep apnoea is a potentially serious sleep disorder associated with the risk of cardiovascular disease. It is treated with continuous airway pressure (CPAP) but this is not always successful. Unsuccessful cases should be treated by bilevel positive airway pressure (BiPAP). The aim of this study was to determine whether common respiratory parameters and/or body mass index (BMI) can be used to predict the probability CPAP failure and hence start such patients on BiPAP from the outset. METHODS: A sample of patients treated by CPAP for OSAS was evaluated a retrospective cohort study. The data measured in sleep monitoring of the successfully treated group and of the group where CPAP had failed were compared. Subsequently, the predictive abilities of BMI, Apnoea Index (AI), Apnoea-Hypopnea Index (AHI), percentage of sleep time in less than 90% oxygen saturation (T90), average oxygen saturation over the duration of sleep (SaO2) and average desaturation per hour of sleep (ODI) were assessed with respect to CPAP failure, both individually and in combination. RESULTS: A sample of 479 patients was included in the study. All of the recorded variables except AI were significantly associated with failure of CPAP and their ability to predict the failure ranged from poor to moderate. Since there was significant correlation among all the variables measured a two-variable prediction model combining T90 and BMI produced no significant improvement in the quality of CPAP failure prediction. CONCLUSIONS: BMI was a significant predictor of CPAP failure although it was slightly less predictive than T90. The set of monitored variables included in our study does not allow for CPAP failure to be predicted with clinically relevant reliability.
- 650 _2
- $a plocha pod křivkou $7 D019540
- 650 _2
- $a index tělesné hmotnosti $7 D015992
- 650 12
- $a trvalý přetlak v dýchacích cestách $7 D045422
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a obezita $x komplikace $7 D009765
- 650 _2
- $a ROC křivka $7 D012372
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a rizikové faktory $7 D012307
- 650 _2
- $a obstrukční spánková apnoe $x komplikace $x terapie $7 D020181
- 650 _2
- $a neúspěšná terapie $7 D017211
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a pozorovací studie $7 D064888
- 700 1_
- $a Honnerová, Monika $7 xx0236687 $u Department of Pneumology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic
- 700 1_
- $a Hošek, Petr $u Biomedical Center, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic $7 xx0224573
- 700 1_
- $a Matas, Ales $u Department of Mathematics, Faculty of Applied Sciences, University of West Bohemia Pilsen, Pilsen, Czech Republic
- 700 1_
- $a Sláma, Karel, $u Department of Otorhinolaryngology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic $d 1971- $7 xx0001667
- 700 1_
- $a Landsmanová, Jana, $d 1981- $7 xx0236685 $u Department of Gynaecology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic
- 700 1_
- $a Kučera, Radek $u Laboratory of Immunoanalysis, Department of Nuclear Medicine, Medical School and Teaching Hospital in Pilsen, Charles University in Prague, Pilsen, Czech Republic $7 jo2016919265
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czech Republic $x 1213-8118 $g Roč. 162, č. 2 (2018), s. 134-138
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29358787 $y Pubmed
- 910 __
- $a ABA008 $b A 1502 $c 958 $y 4 $z 0
- 990 __
- $a 20181123 $b ABA008
- 991 __
- $a 20190603144417 $b ABA008
- 999 __
- $a ok $b bmc $g 1356012 $s 1035702
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 162 $c 2 $d 134-138 $e 20180118 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK118 $a Pubmed-20181123