Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Risk factors for failure of continuous positive airway pressure treatment in patients with ostructive sleep apnoea

D. Slouka, M. Honnerova, P. Hosek, A. Matas, K. Slama, J. Landsmanova, R. Kucera

. 2018 ; 162 (2) : 134-138. [pub] 20180118

Language English Country Czech Republic

Document type Journal Article, Observational Study

BACKGROUND AND AIMS: Obstructive sleep apnoea is a potentially serious sleep disorder associated with the risk of cardiovascular disease. It is treated with continuous airway pressure (CPAP) but this is not always successful. Unsuccessful cases should be treated by bilevel positive airway pressure (BiPAP). The aim of this study was to determine whether common respiratory parameters and/or body mass index (BMI) can be used to predict the probability CPAP failure and hence start such patients on BiPAP from the outset. METHODS: A sample of patients treated by CPAP for OSAS was evaluated a retrospective cohort study. The data measured in sleep monitoring of the successfully treated group and of the group where CPAP had failed were compared. Subsequently, the predictive abilities of BMI, Apnoea Index (AI), Apnoea-Hypopnea Index (AHI), percentage of sleep time in less than 90% oxygen saturation (T90), average oxygen saturation over the duration of sleep (SaO2) and average desaturation per hour of sleep (ODI) were assessed with respect to CPAP failure, both individually and in combination. RESULTS: A sample of 479 patients was included in the study. All of the recorded variables except AI were significantly associated with failure of CPAP and their ability to predict the failure ranged from poor to moderate. Since there was significant correlation among all the variables measured a two-variable prediction model combining T90 and BMI produced no significant improvement in the quality of CPAP failure prediction. CONCLUSIONS: BMI was a significant predictor of CPAP failure although it was slightly less predictive than T90. The set of monitored variables included in our study does not allow for CPAP failure to be predicted with clinically relevant reliability.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18038663
003      
CZ-PrNML
005      
20190603144244.0
007      
ta
008      
181123s2018 xr d f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2017.056 $2 doi
035    __
$a (PubMed)29358787
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Slouka, David $u Department of Otorhinolaryngology, Faculty of Medicine in Plzen, Charles University in Prague, E Pilsen, Czech Republic $7 xx0139295
245    10
$a Risk factors for failure of continuous positive airway pressure treatment in patients with ostructive sleep apnoea / $c D. Slouka, M. Honnerova, P. Hosek, A. Matas, K. Slama, J. Landsmanova, R. Kucera
520    9_
$a BACKGROUND AND AIMS: Obstructive sleep apnoea is a potentially serious sleep disorder associated with the risk of cardiovascular disease. It is treated with continuous airway pressure (CPAP) but this is not always successful. Unsuccessful cases should be treated by bilevel positive airway pressure (BiPAP). The aim of this study was to determine whether common respiratory parameters and/or body mass index (BMI) can be used to predict the probability CPAP failure and hence start such patients on BiPAP from the outset. METHODS: A sample of patients treated by CPAP for OSAS was evaluated a retrospective cohort study. The data measured in sleep monitoring of the successfully treated group and of the group where CPAP had failed were compared. Subsequently, the predictive abilities of BMI, Apnoea Index (AI), Apnoea-Hypopnea Index (AHI), percentage of sleep time in less than 90% oxygen saturation (T90), average oxygen saturation over the duration of sleep (SaO2) and average desaturation per hour of sleep (ODI) were assessed with respect to CPAP failure, both individually and in combination. RESULTS: A sample of 479 patients was included in the study. All of the recorded variables except AI were significantly associated with failure of CPAP and their ability to predict the failure ranged from poor to moderate. Since there was significant correlation among all the variables measured a two-variable prediction model combining T90 and BMI produced no significant improvement in the quality of CPAP failure prediction. CONCLUSIONS: BMI was a significant predictor of CPAP failure although it was slightly less predictive than T90. The set of monitored variables included in our study does not allow for CPAP failure to be predicted with clinically relevant reliability.
650    _2
$a plocha pod křivkou $7 D019540
650    _2
$a index tělesné hmotnosti $7 D015992
650    12
$a trvalý přetlak v dýchacích cestách $7 D045422
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a obezita $x komplikace $7 D009765
650    _2
$a ROC křivka $7 D012372
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a rizikové faktory $7 D012307
650    _2
$a obstrukční spánková apnoe $x komplikace $x terapie $7 D020181
650    _2
$a neúspěšná terapie $7 D017211
655    _2
$a časopisecké články $7 D016428
655    _2
$a pozorovací studie $7 D064888
700    1_
$a Honnerová, Monika $7 xx0236687 $u Department of Pneumology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic
700    1_
$a Hošek, Petr $u Biomedical Center, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic $7 xx0224573
700    1_
$a Matas, Ales $u Department of Mathematics, Faculty of Applied Sciences, University of West Bohemia Pilsen, Pilsen, Czech Republic
700    1_
$a Sláma, Karel, $u Department of Otorhinolaryngology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic $d 1971- $7 xx0001667
700    1_
$a Landsmanová, Jana, $d 1981- $7 xx0236685 $u Department of Gynaecology, Faculty of Medicine in Plzen, Charles University in Prague, Pilsen, Czech Republic
700    1_
$a Kučera, Radek $u Laboratory of Immunoanalysis, Department of Nuclear Medicine, Medical School and Teaching Hospital in Pilsen, Charles University in Prague, Pilsen, Czech Republic $7 jo2016919265
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czech Republic $x 1213-8118 $g Roč. 162, č. 2 (2018), s. 134-138
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29358787 $y Pubmed
910    __
$a ABA008 $b A 1502 $c 958 $y 4 $z 0
990    __
$a 20181123 $b ABA008
991    __
$a 20190603144417 $b ABA008
999    __
$a ok $b bmc $g 1356012 $s 1035702
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 162 $c 2 $d 134-138 $e 20180118 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK118 $a Pubmed-20181123

Find record

Citation metrics

Loading data ...

Archiving options