CROSS SECTIONS MEASURED BY QUASI-MONOENERGETIC NEUTRONS
M. Majerle, M. Ansorge, P. Bém, J. Novák, E. Šimecková, M. Štefánik,
Language English Country England, Great Britain
Document type Journal Article
PubMed
29474643
DOI
10.1093/rpd/ncy031
Knihovny.cz E-resources
- MeSH
- Particle Accelerators instrumentation MeSH
- Databases, Factual MeSH
- Radiation Dosage MeSH
- Equipment Design MeSH
- Lithium chemistry MeSH
- Neutrons * MeSH
- Computer Simulation MeSH
- Radiometry instrumentation methods MeSH
- Publication type
- Journal Article MeSH
197Au, 209Bi, 59Co, natFe and 169Tm samples were irradiated several times with quasi-monoenergetic neutrons from the p+7Li reaction in the energy range of 18-34 MeV. The activities of the samples were measured with the HPGe detector and the reaction rates were calculated. The cross sections were extracted using the SAND-II code with the reference cross sections from the IRDFF database.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19000901
- 003
- CZ-PrNML
- 005
- 20190108130100.0
- 007
- ta
- 008
- 190107s2018 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncy031 $2 doi
- 035 __
- $a (PubMed)29474643
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Majerle, Mitja $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 245 10
- $a CROSS SECTIONS MEASURED BY QUASI-MONOENERGETIC NEUTRONS / $c M. Majerle, M. Ansorge, P. Bém, J. Novák, E. Šimecková, M. Štefánik,
- 520 9_
- $a 197Au, 209Bi, 59Co, natFe and 169Tm samples were irradiated several times with quasi-monoenergetic neutrons from the p+7Li reaction in the energy range of 18-34 MeV. The activities of the samples were measured with the HPGe detector and the reaction rates were calculated. The cross sections were extracted using the SAND-II code with the reference cross sections from the IRDFF database.
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a databáze faktografické $7 D016208
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a lithium $x chemie $7 D008094
- 650 12
- $a neutrony $7 D009502
- 650 _2
- $a částice - urychlovače $x přístrojové vybavení $7 D010315
- 650 _2
- $a dávka záření $7 D011829
- 650 _2
- $a radiometrie $x přístrojové vybavení $x metody $7 D011874
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Ansorge, Martin $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 700 1_
- $a Bém, Pavel $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 700 1_
- $a Novák, Jan $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 700 1_
- $a Šimecková, Eva $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 700 1_
- $a Štefánik, Milan $u Nuclear Physics Institute of the CAS, 250 68 Rež near Prague, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 180, č. 1-4 (2018), s. 386-390
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29474643 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190107 $b ABA008
- 991 __
- $a 20190108130301 $b ABA008
- 999 __
- $a ok $b bmc $g 1364879 $s 1039024
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 180 $c 1-4 $d 386-390 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20190107